The arrangement of electrolyte inlet in the copper electro-refining(ER)cell has a great influence on the local flow field,which affects the distribution of electrical current density in consequence.In order to underst...The arrangement of electrolyte inlet in the copper electro-refining(ER)cell has a great influence on the local flow field,which affects the distribution of electrical current density in consequence.In order to understand the complicated phenomena ofelectrolyte flow behavior in vertical counter electrodes in full-scale copper ER cell,the three-dimensional computational fluiddynamics(CFD)models with four different arrangements of electrolyte inlets,i.e.,single inlet(SI),central bottom inlets(CBI),topside interlaced inlets(TII),and bottom side interlaced inlets(BII),were established to simulate the flow behavior.Simulation resultshave revealed that the parallel injection devices help to improve the electrolyte velocity between electrodes,and while the relativerange of electrolyte velocity in CBI exceeds that of TII and BII,which is more than4times,indicating its severer unequal flowdistribution.Meanwhile,the average velocity of electrolyte in BII is4times larger than that of SI due to its higher turbulenceintensity.Generally,one of the efficient ways to supply fresh copper solution rapidly and uniformly into the inter-electrode space is toadapt the arrangement of BII.By utilizing such an arrangement,the electro-refining under high electrical current density is possible,and the productivity can be increased in sequence.展开更多
基金Project(61321003)supported by the National Natural Science Foundation of China
文摘The arrangement of electrolyte inlet in the copper electro-refining(ER)cell has a great influence on the local flow field,which affects the distribution of electrical current density in consequence.In order to understand the complicated phenomena ofelectrolyte flow behavior in vertical counter electrodes in full-scale copper ER cell,the three-dimensional computational fluiddynamics(CFD)models with four different arrangements of electrolyte inlets,i.e.,single inlet(SI),central bottom inlets(CBI),topside interlaced inlets(TII),and bottom side interlaced inlets(BII),were established to simulate the flow behavior.Simulation resultshave revealed that the parallel injection devices help to improve the electrolyte velocity between electrodes,and while the relativerange of electrolyte velocity in CBI exceeds that of TII and BII,which is more than4times,indicating its severer unequal flowdistribution.Meanwhile,the average velocity of electrolyte in BII is4times larger than that of SI due to its higher turbulenceintensity.Generally,one of the efficient ways to supply fresh copper solution rapidly and uniformly into the inter-electrode space is toadapt the arrangement of BII.By utilizing such an arrangement,the electro-refining under high electrical current density is possible,and the productivity can be increased in sequence.