Due to inadequate bearing capacity of the chemically-planted steel bar in low-strength concrete, a new mixed post-installed connection is proposed using small diameter anchoring steel bars and grouting materials toget...Due to inadequate bearing capacity of the chemically-planted steel bar in low-strength concrete, a new mixed post-installed connection is proposed using small diameter anchoring steel bars and grouting materials together to anchor the main steel bar. To investigate the feasibility of the proposed post-installed connections, a series of pull-out tests with different anchors were conducted for comparison,including fully adhesive anchors, partially adhesive anchors,grouting material anchoring connection and the new mixed post-installed connection. The experimental results of the single steel bar pull-out test show that the mixed post-installed connection can effectively enhance the bearing capacity of post-installed steel bars in low-strength concrete. The bearing capacity is increased by nearly two times with no cone-type concrete failure compared with the fully adhesive anchor. The results show that adopting the new mixed post-installed connection can ensure that joint performance meets the requirements if the space dimension is available.展开更多
So far, numerous numerical studies have been conducted on the behavior of Composite Reinforced Concrete-Steel (RCS) beam-to-column connections. However, the lack of studies regarding the steel joist-concrete girder ...So far, numerous numerical studies have been conducted on the behavior of Composite Reinforced Concrete-Steel (RCS) beam-to-column connections. However, the lack of studies regarding the steel joist-concrete girder connection has yet to be addressed through comprehensive finite element methods to get an understanding of influential parameters. Hence, in this paper, composite connection of embedded steel joist in concrete girder is investigated with an appropriate finite element software, namely, ABAQUS. The validity of the proposed model is examined by the comparison made with the test data in literature. Results indicate that maximum bending capacity of the connection is achieved when embedment ratio is 1.78. Moreover, double web angles in the embedment region significantly reduce the embedment length required to achieve the maximum bending capacity. Finally, damage analyses show that bending capacity of concrete girder is slightly reduced in the connection zone.展开更多
基金The National Natural Science Foundation of China(No.51409084)the Natural Science Foundation of Jiangsu Province(No.BK20130836)
文摘Due to inadequate bearing capacity of the chemically-planted steel bar in low-strength concrete, a new mixed post-installed connection is proposed using small diameter anchoring steel bars and grouting materials together to anchor the main steel bar. To investigate the feasibility of the proposed post-installed connections, a series of pull-out tests with different anchors were conducted for comparison,including fully adhesive anchors, partially adhesive anchors,grouting material anchoring connection and the new mixed post-installed connection. The experimental results of the single steel bar pull-out test show that the mixed post-installed connection can effectively enhance the bearing capacity of post-installed steel bars in low-strength concrete. The bearing capacity is increased by nearly two times with no cone-type concrete failure compared with the fully adhesive anchor. The results show that adopting the new mixed post-installed connection can ensure that joint performance meets the requirements if the space dimension is available.
文摘So far, numerous numerical studies have been conducted on the behavior of Composite Reinforced Concrete-Steel (RCS) beam-to-column connections. However, the lack of studies regarding the steel joist-concrete girder connection has yet to be addressed through comprehensive finite element methods to get an understanding of influential parameters. Hence, in this paper, composite connection of embedded steel joist in concrete girder is investigated with an appropriate finite element software, namely, ABAQUS. The validity of the proposed model is examined by the comparison made with the test data in literature. Results indicate that maximum bending capacity of the connection is achieved when embedment ratio is 1.78. Moreover, double web angles in the embedment region significantly reduce the embedment length required to achieve the maximum bending capacity. Finally, damage analyses show that bending capacity of concrete girder is slightly reduced in the connection zone.