Objective: To study the memory biomechanical character of anatomic distal radius Nitinol memory connector (DRMC) in treating distal radius fracture. Methods: Establishing three dimensional model and finite element ana...Objective: To study the memory biomechanical character of anatomic distal radius Nitinol memory connector (DRMC) in treating distal radius fracture. Methods: Establishing three dimensional model and finite element analysis, we calculated the stress in and around the fracture faces when distal radius fracture was fixated with DRMC. Results: Axial holding stress produced by holding part of DRMC on distal radius was 14.66 MPa. The maximum stress of holding part was 40-70 MPa, the minimum stress was 3-7 MPa,and the stress of compression part was 20-40 MPa. Conclusion: The distribution of stress produced by DRMC around the fracture line is reasonable, and axial holding stress can help stabilize fracture during earlier period. The existence of longitudal compression and memory effect can transfer fixated disused section into developed section and enhance fracture healing.展开更多
The copper-based shape memory alloy pipe joint was applied in the field of oil pipelines jointing as well as installing. It has many advantages than anything. In the paper, the basic principle and connection influence...The copper-based shape memory alloy pipe joint was applied in the field of oil pipelines jointing as well as installing. It has many advantages than anything. In the paper, the basic principle and connection influence factors of copper-based shape memory alloy pipe joint were described. Experimental results shows the copper-based shape memory alloy pipe joints can be used in oilfield oil pipeline connection and it can solve the inner pipe joint corrosion damage problem by welding.展开更多
文摘Objective: To study the memory biomechanical character of anatomic distal radius Nitinol memory connector (DRMC) in treating distal radius fracture. Methods: Establishing three dimensional model and finite element analysis, we calculated the stress in and around the fracture faces when distal radius fracture was fixated with DRMC. Results: Axial holding stress produced by holding part of DRMC on distal radius was 14.66 MPa. The maximum stress of holding part was 40-70 MPa, the minimum stress was 3-7 MPa,and the stress of compression part was 20-40 MPa. Conclusion: The distribution of stress produced by DRMC around the fracture line is reasonable, and axial holding stress can help stabilize fracture during earlier period. The existence of longitudal compression and memory effect can transfer fixated disused section into developed section and enhance fracture healing.
文摘The copper-based shape memory alloy pipe joint was applied in the field of oil pipelines jointing as well as installing. It has many advantages than anything. In the paper, the basic principle and connection influence factors of copper-based shape memory alloy pipe joint were described. Experimental results shows the copper-based shape memory alloy pipe joints can be used in oilfield oil pipeline connection and it can solve the inner pipe joint corrosion damage problem by welding.