The controlling algorithm was studied for the inverter-driven multi-type air conditioner using electronic expansion valve(EEV) in outdoor unit. The performance of inverter-driven air conditioner with two different uni...The controlling algorithm was studied for the inverter-driven multi-type air conditioner using electronic expansion valve(EEV) in outdoor unit. The performance of inverter-driven air conditioner with two different units was investigated by varying the outdoor ambient temperature and compressor speed. Based on the test results, the effect of EEV opening on the indoor unit exit superheat was discussed. For the specified outdoor ambient temperature scope and the EEV opening, the superheats of indoor units decrease with the outdoor ambient temperature rising. Improper distribution of refrigerant into each indoor unit will causes excessive superheat difference between two indoor units. Suggestions were then given for the controlling of the superheat.展开更多
This paper presents a single-phase Z-source inverter as a power conditioning system for a single phase utility connected system. Z-source inverter is a single-stage topology that has buck-boost feature, which is possi...This paper presents a single-phase Z-source inverter as a power conditioning system for a single phase utility connected system. Z-source inverter is a single-stage topology that has buck-boost feature, which is possible because of additional shoot through state introduced in zero state of the conventional inverter pulse width modulation and provides desired output AC voltage. Small distributed generation (DG) system with alternate energy sources requires power conditioning units with low cost, high efficiency and tolerance to wide range of input voltage variation and has to perform various functions such as dc-ac conversion, system control and achieve power quality norms. To meet some of these requirements a two-loop control strategy for ac side control with grid current feedback with PI control and inner filter capacitor current feedback with proportional control and on dc side PID control for Z-source capacitor voltage regulation are employed, which gives good transient response also suppress load and source disturbances effectively. Theoretical analysis of proposed scheme is established and then simulation results are presented to validate proposed control strategy.展开更多
文摘The controlling algorithm was studied for the inverter-driven multi-type air conditioner using electronic expansion valve(EEV) in outdoor unit. The performance of inverter-driven air conditioner with two different units was investigated by varying the outdoor ambient temperature and compressor speed. Based on the test results, the effect of EEV opening on the indoor unit exit superheat was discussed. For the specified outdoor ambient temperature scope and the EEV opening, the superheats of indoor units decrease with the outdoor ambient temperature rising. Improper distribution of refrigerant into each indoor unit will causes excessive superheat difference between two indoor units. Suggestions were then given for the controlling of the superheat.
文摘This paper presents a single-phase Z-source inverter as a power conditioning system for a single phase utility connected system. Z-source inverter is a single-stage topology that has buck-boost feature, which is possible because of additional shoot through state introduced in zero state of the conventional inverter pulse width modulation and provides desired output AC voltage. Small distributed generation (DG) system with alternate energy sources requires power conditioning units with low cost, high efficiency and tolerance to wide range of input voltage variation and has to perform various functions such as dc-ac conversion, system control and achieve power quality norms. To meet some of these requirements a two-loop control strategy for ac side control with grid current feedback with PI control and inner filter capacitor current feedback with proportional control and on dc side PID control for Z-source capacitor voltage regulation are employed, which gives good transient response also suppress load and source disturbances effectively. Theoretical analysis of proposed scheme is established and then simulation results are presented to validate proposed control strategy.