期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
泪道阻塞再通管逆向置入治疗慢性泪囊炎疗效观察
1
作者 周蓉 《吉林医学》 CAS 2011年第20期4188-4189,共2页
目的:回顾性观察分析因鼻泪管阻塞所致的慢性泪囊炎在临床上的疗效,并记录相关观察结果,从而提高临床诊断率。方法:对102例(106眼)慢性泪囊炎采用4步操作手术,将泪道阻塞再通管逆向置人泪道的方法治疗。结果:2例(2眼)探通时形成假道放... 目的:回顾性观察分析因鼻泪管阻塞所致的慢性泪囊炎在临床上的疗效,并记录相关观察结果,从而提高临床诊断率。方法:对102例(106眼)慢性泪囊炎采用4步操作手术,将泪道阻塞再通管逆向置人泪道的方法治疗。结果:2例(2眼)探通时形成假道放弃手术,失败率1.89%;2例(2眼)致泪点轻度裂伤,占1.89%;其余98例(102眼),占96.08%,患者溢泪、溢脓症状消失,泪道冲洗全部通畅。随访时间1个月~4年,无过敏反应及其他刺激不适反应。结论:泪道阻塞再通管逆向置入泪道治疗慢性泪囊炎疗效良好,操作简单,经济,门诊即可手术。 展开更多
关键词 慢性泪囊炎 泪道阻塞再通管 逆向置入治疗 疗效观察
下载PDF
泪道阻塞再通管逆向置入治疗慢性泪囊炎临床分析 被引量:1
2
作者 马瑞雪 马惠玲 +1 位作者 王海蓉 李彩霞 《眼外伤职业眼病杂志》 北大核心 2007年第11期897-898,共2页
目的探讨因鼻泪管阻塞所致的慢性泪囊炎的治疗方法。方法对51例(53眼)慢性泪囊炎采用4步操作手术,将泪道阻塞再通管逆向置入泪道的方法治疗。结果1例(1眼)探通时形成假道放弃手术,失败率1.89%;1例(1眼)致泪点轻度裂伤,占1.89%;其余49例... 目的探讨因鼻泪管阻塞所致的慢性泪囊炎的治疗方法。方法对51例(53眼)慢性泪囊炎采用4步操作手术,将泪道阻塞再通管逆向置入泪道的方法治疗。结果1例(1眼)探通时形成假道放弃手术,失败率1.89%;1例(1眼)致泪点轻度裂伤,占1.89%;其余49例(51眼),占96.23%,患者溢泪,溢脓症状消失,泪道冲洗全部通畅。随访时间1月~4年,无过敏反应及其他刺激不适反应。结论泪道阻塞再通管逆向置入泪道治疗慢性泪囊炎疗效良好,操作简单,经济,门诊即可手术。 展开更多
关键词 慢性泪囊炎 泪道阻塞再通管 逆向置入
下载PDF
经胃造口逆向植入支架治疗食管癌性狭窄和瘘2例报道
3
作者 刘明 叶震世 +5 位作者 施华秀 蔡宝英 许立新 刘平果 刘忠臣 马保新 《中国消化内镜》 2009年第3期9-14,共6页
目的探讨经过胃手术造口途径逆向置放食管支架治疗食管瘘的可行性。方法使用手术腹壁胃造口途径经由贲门至食管逆向操作,反向置入食管被膜支架以治疗食管癌性狭窄和瘘。结果二例晚期食管癌患者因食管严重狭窄迂曲,引导钢丝不能经口顺向... 目的探讨经过胃手术造口途径逆向置放食管支架治疗食管瘘的可行性。方法使用手术腹壁胃造口途径经由贲门至食管逆向操作,反向置入食管被膜支架以治疗食管癌性狭窄和瘘。结果二例晚期食管癌患者因食管严重狭窄迂曲,引导钢丝不能经口顺向通过病变段,导致采用常规方法无法置放食管支架;后改经手术胃造口途径逆向植入食管被膜支架均获得成功,食管瘘口被完全封堵,食管狭窄解除,恢复经口进食。其中一例因高龄及原先吸入性肺炎无法控制终至呼吸衰竭而死亡,另一例存活一年后因癌转移而死亡。结论经手术胃造口逆向植入食管支架方式治疗复杂食管癌性狭窄和瘘切实可行,但需要积极尽早实施方能收到最佳疗效。 展开更多
关键词 食管癌性狭窄 支架 胃造口 逆向置入
下载PDF
Rapid prototyping drill guide template for lumbar pedicle screw placement 被引量:25
4
作者 陆声 徐永清 +4 位作者 张元智 李严兵 师继红 陈国平 陈玉兵 《Chinese Journal of Traumatology》 CAS 2009年第3期177-180,共4页
Objective: To develop a novel method of spinal pedical stereotaxy by reverse engineering and rapid prototyping techniques, and to validate its accuracy by experimental and clinical studies. Methods: A 3D reconstruc... Objective: To develop a novel method of spinal pedical stereotaxy by reverse engineering and rapid prototyping techniques, and to validate its accuracy by experimental and clinical studies. Methods: A 3D reconstruction model for the desired lumbar vertebra was generated by using the Mimics 10.11 software, and the optimal screw size and orientation were determined using the reverse engineering software. Afterwards, a drill template was created by reverse engineering principle, whose surface was the antitemplate of the vertebral surface. The drill template and its corresponding vertebra were manufactured using the rapid prototyping technique. Results: The accuracy of the drill template was confinned by drilling screw trajectory into the vertebral biomodel preoperatively. This method also showed its ability to customize the placement and size of each screw based on the unique morphology of the lumbar vertebra.The drill template fits the postural surface of the vertebra very well in the cadaver experiment. Postoperative CT scans for controlling the pedicle bore showed that the personalized template had a high precision in cadaver experiment and clinical application. No misplacement occurred by using the personalized template. During surgery, no additional computer assistance was needed. Conclusions: The authors have developed a novel drill template for lumbar pedicle screw placement with good applicability and high accuracy. The potential use of drill templates to place lumbar pedicle screws is promising, Our methodology appears to provide an accurate technique and trajectory for pedicle screw placement in the lumbar spine. 展开更多
关键词 NEURONAVIGATION TEMPLATE Lumbar vertebrae Bone screws
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部