期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
稳定化有限元方法中逆估计常数的确定 被引量:2
1
作者 段火元 《计算数学》 CSCD 北大核心 1998年第4期403-408,共6页
A unified computable formula is presented for the constant of inverse estimation emanating from stabilized finite element methods. The method lies in introducing an elementwise bubble space spanned by the interpolatio... A unified computable formula is presented for the constant of inverse estimation emanating from stabilized finite element methods. The method lies in introducing an elementwise bubble space spanned by the interpolation base functions with an additional bubble function given,and the parameter playing a stabilization role can take its value in a determined range. 展开更多
关键词 估计 稳定化有限元 有限元 逆常数
原文传递
求解不可压缩Navier-Stokes方程的GLS平面八节点单元
2
作者 魏晓娟 刘力菱 +2 位作者 谢凌志 易丽清 魏泳涛 《流体动力学》 2013年第2期15-20,共6页
给出了求解不可压缩Navier-Stokes方程的GLS平面八节点单元的“单元长度”的定义和相应的逆估计常数,由此可计算出该单元的GLS稳定因子。给出的“单元长度”只依赖单元形状且易于计算;各种形状的直边四边形单元的逆估计常数的最大值由... 给出了求解不可压缩Navier-Stokes方程的GLS平面八节点单元的“单元长度”的定义和相应的逆估计常数,由此可计算出该单元的GLS稳定因子。给出的“单元长度”只依赖单元形状且易于计算;各种形状的直边四边形单元的逆估计常数的最大值由遗传算法得出。对Reynolds数为20,000的方腔上盖板流的数值模拟表明,本文所提出的单元长度和逆估计常数的正确性。 展开更多
关键词 Galerkin/最小二乘有限元 稳定因子 单元长度 估计常数
下载PDF
Spectroscopic and electrochemical properties of Cu-dicyandiamide complex
3
作者 Kai-Xuan Xu Mei-Hong Guo +2 位作者 Ling-Qing Ren Wei Huang Jian-Jun Sun 《Science China Chemistry》 SCIE EI CAS CSCD 2018年第3期360-367,共8页
Dicyandiamide(DICY) is a common ligand that exhibits low toxicity but can irritate the skin and eyes and cause methemoglobinemia on long-term exposure. Crystalline Cu-dicyandiamide(Cu-DICY) was obtained via facile syn... Dicyandiamide(DICY) is a common ligand that exhibits low toxicity but can irritate the skin and eyes and cause methemoglobinemia on long-term exposure. Crystalline Cu-dicyandiamide(Cu-DICY) was obtained via facile synthesis and its molecular structure and theoretical Raman spectra were simulated by using density functional theory(DFT). The results suggested that the Cu^(2+) coordinates with two H_2 O molecules and two different DICY molecules(an imino DICY and an amino DICY). The stability constants of Cu-DICY were calculated, and the electrochemical properties were studied. Two electrochemical redox processes occur in Cu-DICY in an aqueous solution: a reversible reaction with a formal potential of 0.2 V vs.MSE and an irreversible reaction between –0.4 and –1.2 V vs. MSE. The standard rate constant k0 for the reversible reaction was estimated to be 7.6×10^(-3) cm/s. In addition, based on the reversible reaction of Cu-DICY, square wave voltammetry was used to rapidly determine the concentration of Cu(II) and the detection limit was 66.7 μg/L, which satisfies the detection limit requirements for copper in tap water(2 mg/L) as provided by the World Health Organization. 展开更多
关键词 Cu-dicyandiamide density functional theory Raman spectra square wave voltammetry
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部