Forced convective experiment of supercritical water was performed in Inconel-625 tubes of 4.62 mm, 7.98 mm and 10.89 mm in diameter. The water flowed upward, covering the ranges of pressure of 23.4 MPa to 25.8 MPa, ma...Forced convective experiment of supercritical water was performed in Inconel-625 tubes of 4.62 mm, 7.98 mm and 10.89 mm in diameter. The water flowed upward, covering the ranges of pressure of 23.4 MPa to 25.8 MPa, mass flux of 90 kg/m^2s to 3,281 kg/m^2s, local bulk temperature of 102-384 ℃, inner wall temperature of 167-669℃ and heat flux of up to 2.41 MW/m^2. The results exhibited severe deteriorated and enhancement heat transfer. The experimental results can be calculated by the Jackson's correlation and the Bishop's correlation mostly. But some data with strong effects of the buoyancy force and the variations of flow regimes can not be predicted properly.展开更多
文摘Forced convective experiment of supercritical water was performed in Inconel-625 tubes of 4.62 mm, 7.98 mm and 10.89 mm in diameter. The water flowed upward, covering the ranges of pressure of 23.4 MPa to 25.8 MPa, mass flux of 90 kg/m^2s to 3,281 kg/m^2s, local bulk temperature of 102-384 ℃, inner wall temperature of 167-669℃ and heat flux of up to 2.41 MW/m^2. The results exhibited severe deteriorated and enhancement heat transfer. The experimental results can be calculated by the Jackson's correlation and the Bishop's correlation mostly. But some data with strong effects of the buoyancy force and the variations of flow regimes can not be predicted properly.