Objective To observe value of 0D-1D coupling model and 3D fluid-structure interaction(FSI)model based on coronary CT angiography(CCTA)for displaying hemodynamic characteristics of coronary artery stenosis.Methods Base...Objective To observe value of 0D-1D coupling model and 3D fluid-structure interaction(FSI)model based on coronary CT angiography(CCTA)for displaying hemodynamic characteristics of coronary artery stenosis.Methods Based on CCTA data of the stenosed left anterior descending branch(LAD)in a patient with coronary heart disease,an 0D-1D coupling model and 3D FSI model were built,respectively.Then hemodynamic characteristic indexes,including the pressure,flow velocity and wall shear stress(WSS)were obtained in every 0.01 s during 1 s at 5 sampling points(i.e.sampling point 1—5)using these 2 models,respectively,and the consistencies of the results between models were evaluated with Spearman correlation coefficient r s.Results The time consuming for construction of 0D-1D coupling model and 3D FSI model was 0.033 min and 704 min,respectively.Both models showed basically distribution of the pressure,flow velocity and WSS of the stenosed LAD.For more details,the pressure at the stenosed segment of LAD and the proximal segment of stenosis were both higher,which gradually decreased at the distal segment of stenosis,and the flow velocity at the proximal segment of stenosis was in a relatively slow and uniform condition,with significantly increased flow velocity and WSS at the stenosed segment.Compared with 3D FSI model,0D-1D vascular coupling model was relatively unrefined and lack of distal flow lines when displaying blood flow velocity.For sampling point 2 at the stenosed segment of LAD,no significant consistency for pressure between 2 models was found(P=0.118),but strong consistency for the flow velocity and WSS(r s=0.730,0.807,both P<0.05).The consistencies of pressure,flow velocity and WSS between 2 models at the proximal and distal segment of stenosis,i.e.1,3—5 sampling points were week to moderate(r s=0.237—0.669,all P<0.05).Conclusion 0D-1D coupling model exhibited outstanding computational efficiency and might provide relatively reasonable results,while 3D FSI model showed higher accuracy for details and streamline when simulating LAD stenosis.展开更多
Gravity die casting(GC) and squeeze casting(SC) T4-treated Al-7.0Zn-2.5Mg-2.1Cu alloys were employed to investigate the microstructures,mechanical properties and low cycle fatigue(LCF) behavior.The results show that m...Gravity die casting(GC) and squeeze casting(SC) T4-treated Al-7.0Zn-2.5Mg-2.1Cu alloys were employed to investigate the microstructures,mechanical properties and low cycle fatigue(LCF) behavior.The results show that mechanical properties of SC specimens are significantly better than those of GC specimens due to less cast defects and smaller secondary dendrite arm spacing(SDAS).Excellent fatigue properties are obtained for the SC alloy compared with the GC alloy.GC and SC alloys both exhibit cyclic stabilization at low total strain amplitudes(less than 0.4%) and cyclic hardening at higher total strain amplitudes.The degree of cyclic hardening of SC samples is greater than that of GC samples.Fatigue cracks of GC samples dominantly initiate from shrinkage porosities and are easy to propagate along them,while the crack initiation sites for SC samples are slip bands,eutectic phases and inclusions at or near the free surface.展开更多
文摘Objective To observe value of 0D-1D coupling model and 3D fluid-structure interaction(FSI)model based on coronary CT angiography(CCTA)for displaying hemodynamic characteristics of coronary artery stenosis.Methods Based on CCTA data of the stenosed left anterior descending branch(LAD)in a patient with coronary heart disease,an 0D-1D coupling model and 3D FSI model were built,respectively.Then hemodynamic characteristic indexes,including the pressure,flow velocity and wall shear stress(WSS)were obtained in every 0.01 s during 1 s at 5 sampling points(i.e.sampling point 1—5)using these 2 models,respectively,and the consistencies of the results between models were evaluated with Spearman correlation coefficient r s.Results The time consuming for construction of 0D-1D coupling model and 3D FSI model was 0.033 min and 704 min,respectively.Both models showed basically distribution of the pressure,flow velocity and WSS of the stenosed LAD.For more details,the pressure at the stenosed segment of LAD and the proximal segment of stenosis were both higher,which gradually decreased at the distal segment of stenosis,and the flow velocity at the proximal segment of stenosis was in a relatively slow and uniform condition,with significantly increased flow velocity and WSS at the stenosed segment.Compared with 3D FSI model,0D-1D vascular coupling model was relatively unrefined and lack of distal flow lines when displaying blood flow velocity.For sampling point 2 at the stenosed segment of LAD,no significant consistency for pressure between 2 models was found(P=0.118),but strong consistency for the flow velocity and WSS(r s=0.730,0.807,both P<0.05).The consistencies of pressure,flow velocity and WSS between 2 models at the proximal and distal segment of stenosis,i.e.1,3—5 sampling points were week to moderate(r s=0.237—0.669,all P<0.05).Conclusion 0D-1D coupling model exhibited outstanding computational efficiency and might provide relatively reasonable results,while 3D FSI model showed higher accuracy for details and streamline when simulating LAD stenosis.
基金Project(2015A030312003)supported by the Guangdong Natural Science Foundation for Research Team,ChinaProject(51374110)supported by the National Natural Science Foundation of China
文摘Gravity die casting(GC) and squeeze casting(SC) T4-treated Al-7.0Zn-2.5Mg-2.1Cu alloys were employed to investigate the microstructures,mechanical properties and low cycle fatigue(LCF) behavior.The results show that mechanical properties of SC specimens are significantly better than those of GC specimens due to less cast defects and smaller secondary dendrite arm spacing(SDAS).Excellent fatigue properties are obtained for the SC alloy compared with the GC alloy.GC and SC alloys both exhibit cyclic stabilization at low total strain amplitudes(less than 0.4%) and cyclic hardening at higher total strain amplitudes.The degree of cyclic hardening of SC samples is greater than that of GC samples.Fatigue cracks of GC samples dominantly initiate from shrinkage porosities and are easy to propagate along them,while the crack initiation sites for SC samples are slip bands,eutectic phases and inclusions at or near the free surface.