This paper presents a wavelet-based technique for detection and classification of normal and abnormal conditions that occur on power distribution lines. The proposed technique depends on a sensitive fault detection pa...This paper presents a wavelet-based technique for detection and classification of normal and abnormal conditions that occur on power distribution lines. The proposed technique depends on a sensitive fault detection parameter (denoted DET) calculated from the wavelet multi-resolution decomposition of the three phase currents only. This parameter is fast and sensitive to any small changes in the current signal since it uses the square of the first and second details of the decomposed signals. The simulation results of this study clearly show that the proposed technique can be successfully used to detect and classify not only low-current faults that could not be detected by conventional overcurrent relays but also normal transients like load switching and inrush currents.展开更多
the power network fault detection system can only analyze all kinds of fault signal in stationary sequence: the internal grid and external disturbance presents degeneration, tiny, signal intensity changes randomly fl...the power network fault detection system can only analyze all kinds of fault signal in stationary sequence: the internal grid and external disturbance presents degeneration, tiny, signal intensity changes randomly fluctuate, that will cause the system to detect the fault isolation ability of confusion and small fault signal is not strong; The article propose a method of power network fault detection for based on GSM, Through the underlying sensing equipment acquisition abnormal information of current, voltage power in the network and GSM networking scheme can filter the interference factors in extraction of fault information from and attribute value. The embedded gateway take STM32 chip as the core to monitoring data processing, to achieve a unified data management and user remote access, realizing method of system software are given, to construct the monitor management information platform. The actual test system show that, identification diagnosis ability of fault signal separation ability and small signal increases 17%, also meet the requirements.展开更多
This paper presents a novel transient current differential algorithm for earth fault detection in unearthed (isolated) and compensated neutral medium voltage (MV) networks. The proposed algorithm uses the transien...This paper presents a novel transient current differential algorithm for earth fault detection in unearthed (isolated) and compensated neutral medium voltage (MV) networks. The proposed algorithm uses the transient residual currents, which are very sensitive for earth faults detection. The transient values of residual currents are calculated for each feeder in the network and used as an earth fault indicator. The flow of residual currents is investigated. It is found that the residual current for the faulted feeder is equal to the summation of all residual currents for all other healthy feedersl Based on this investigation, a differential technique is proposed. A percentage restrain performance is proposed to ensure the selectivity and security of the algorithm. The transient algorithm is very sensitive for earth fault incidence. To apply the proposed algorithm, the residual currents can be measured easily by one sensor for each feeder with no need to voltage measurement. The proposed algorithm is less dependent on the fault resistance and the faulted feeder parameters. The network is simulated by ATP/EMTP program. Different fault conditions are covered in the simulation process: different fault inception angles, fault locations and fault resistances.展开更多
文摘This paper presents a wavelet-based technique for detection and classification of normal and abnormal conditions that occur on power distribution lines. The proposed technique depends on a sensitive fault detection parameter (denoted DET) calculated from the wavelet multi-resolution decomposition of the three phase currents only. This parameter is fast and sensitive to any small changes in the current signal since it uses the square of the first and second details of the decomposed signals. The simulation results of this study clearly show that the proposed technique can be successfully used to detect and classify not only low-current faults that could not be detected by conventional overcurrent relays but also normal transients like load switching and inrush currents.
文摘the power network fault detection system can only analyze all kinds of fault signal in stationary sequence: the internal grid and external disturbance presents degeneration, tiny, signal intensity changes randomly fluctuate, that will cause the system to detect the fault isolation ability of confusion and small fault signal is not strong; The article propose a method of power network fault detection for based on GSM, Through the underlying sensing equipment acquisition abnormal information of current, voltage power in the network and GSM networking scheme can filter the interference factors in extraction of fault information from and attribute value. The embedded gateway take STM32 chip as the core to monitoring data processing, to achieve a unified data management and user remote access, realizing method of system software are given, to construct the monitor management information platform. The actual test system show that, identification diagnosis ability of fault signal separation ability and small signal increases 17%, also meet the requirements.
文摘This paper presents a novel transient current differential algorithm for earth fault detection in unearthed (isolated) and compensated neutral medium voltage (MV) networks. The proposed algorithm uses the transient residual currents, which are very sensitive for earth faults detection. The transient values of residual currents are calculated for each feeder in the network and used as an earth fault indicator. The flow of residual currents is investigated. It is found that the residual current for the faulted feeder is equal to the summation of all residual currents for all other healthy feedersl Based on this investigation, a differential technique is proposed. A percentage restrain performance is proposed to ensure the selectivity and security of the algorithm. The transient algorithm is very sensitive for earth fault incidence. To apply the proposed algorithm, the residual currents can be measured easily by one sensor for each feeder with no need to voltage measurement. The proposed algorithm is less dependent on the fault resistance and the faulted feeder parameters. The network is simulated by ATP/EMTP program. Different fault conditions are covered in the simulation process: different fault inception angles, fault locations and fault resistances.