A process composed of a fixed-bed and a distillation column with a side withdraw, mainly methanol, is developed to hydrolyze methyl acetate (MA) as a typical byproduct in polyvinyl alcohol (PVA) and pure terephthalic ...A process composed of a fixed-bed and a distillation column with a side withdraw, mainly methanol, is developed to hydrolyze methyl acetate (MA) as a typical byproduct in polyvinyl alcohol (PVA) and pure terephthalic acid (PTA) factory. The process is simulated by employing the equilibrium stage model RadFrac and plug flow model Rplug in Aspen Plus. Experiments are also carried out in a lab-scale to evaluate the process. The results show that at the molar ratio of water to methyl acetate about 4.0-5.0 in the feed stream and the volume ratio of distillate to feed MA above a critical value, the side product contains more than 80% (by mass) (MeOH) and less than 2% (by mass) MA, while the bottom contains more than 46% (by mass) acetic acid (HAc) and less than 0.5% (by mass) methanol with almost complete conversion of MA. Compared with the old catalytic distillation process we proposed before, this process can cut down 47.6% energy consumption and a distillation column.展开更多
A different pressure thermally coupled reactive distillation column(DPT-RD) for the hydrolysis of methyl acetate(Me Ac) is developed, and its design and optimization procedures are investigated. The sensitivity analys...A different pressure thermally coupled reactive distillation column(DPT-RD) for the hydrolysis of methyl acetate(Me Ac) is developed, and its design and optimization procedures are investigated. The sensitivity analysis is carried out to minimize the energy consumption, which is associated with the total annual cost(TAC). The influence of the proposed DPTRD scheme on energy consumption and economic efficiency are evaluated in comparison with the conventional reactive distillation column(CRD). Both the DPT-RD and CRD are simulated with the Aspen Plus?, and it can be observed that for the DPT-RD the energy consumption and the TAC are reduced, and the thermodynamic efficiency is increased as compared with the CRD process.展开更多
基金Supported by the National Torch Program of China (2007HG560031)
文摘A process composed of a fixed-bed and a distillation column with a side withdraw, mainly methanol, is developed to hydrolyze methyl acetate (MA) as a typical byproduct in polyvinyl alcohol (PVA) and pure terephthalic acid (PTA) factory. The process is simulated by employing the equilibrium stage model RadFrac and plug flow model Rplug in Aspen Plus. Experiments are also carried out in a lab-scale to evaluate the process. The results show that at the molar ratio of water to methyl acetate about 4.0-5.0 in the feed stream and the volume ratio of distillate to feed MA above a critical value, the side product contains more than 80% (by mass) (MeOH) and less than 2% (by mass) MA, while the bottom contains more than 46% (by mass) acetic acid (HAc) and less than 0.5% (by mass) methanol with almost complete conversion of MA. Compared with the old catalytic distillation process we proposed before, this process can cut down 47.6% energy consumption and a distillation column.
基金This work was supported by the National Natural Science Foundation of China(Grant Nos.21276279,21476261)the Key Technologies Development Project of Qingdao Economic and Technological Development Zone(Grant No.2013-1-57)+1 种基金the Fundamental Research Funds for the Central Universities(No.14CX05030ANo.14CX06108A).
文摘A different pressure thermally coupled reactive distillation column(DPT-RD) for the hydrolysis of methyl acetate(Me Ac) is developed, and its design and optimization procedures are investigated. The sensitivity analysis is carried out to minimize the energy consumption, which is associated with the total annual cost(TAC). The influence of the proposed DPTRD scheme on energy consumption and economic efficiency are evaluated in comparison with the conventional reactive distillation column(CRD). Both the DPT-RD and CRD are simulated with the Aspen Plus?, and it can be observed that for the DPT-RD the energy consumption and the TAC are reduced, and the thermodynamic efficiency is increased as compared with the CRD process.