Using the recently developed finite-basis-set method with B splines, excited states of H atoms in a magnetic field have been calculated. Energy levels are presented for the ten excited states, 2so, 3d'0, 3po, 3p-1, 3...Using the recently developed finite-basis-set method with B splines, excited states of H atoms in a magnetic field have been calculated. Energy levels are presented for the ten excited states, 2so, 3d'0, 3po, 3p-1, 3d_1, 4d-1, 3d-2, 4d-2, 4f-2 , and 5f-2 as a function of magnetic field strengths with a range from zero up to 2.35 × 10^6 T. The obtained results are compared with available high accuracy theoretical data reported in the literature and found to be in excellent agreement. The comparison also shows that the current method can produce energy levels with an accuracy higher than the existing high accuracy method [Phys. Rev. A 54 (1996) 287]. Here high accuracy energy levels are for the first time reported for the 3d'0, 4d-1, 4d-2, 4f-2, and 5f-2 states.展开更多
Nonalcoholic fatty liver disease(NAFLD),defined by excessive liver fat deposition related to the metabolic syndrome,is a leading cause of progressive liver disease,for which accurate non-invasive staging systems and e...Nonalcoholic fatty liver disease(NAFLD),defined by excessive liver fat deposition related to the metabolic syndrome,is a leading cause of progressive liver disease,for which accurate non-invasive staging systems and effective treatments are still lacking.Evidence has shown that increased ferritin levels are associated with the metabolic insulin resistance syndrome,and higher hepatic iron and fat content.Hyperferritinemia and iron stores have been associated with the severity of liver damage in NAFLD,and iron depletion reduced insulin resistance and liver enzymes.Recently,Kowdley et al demonstrated in a multicenter study in 628 adult patients with NAFLD from the NAFLD-clinical research network database with central re-evaluation of liver histology and iron staining that the increased serum ferritin level is an independent predictor of liver damage in patients with NAFLD,and is useful to identify NAFLD patients at risk of non-alcoholic steatohepatitis and advanced fibrosis.These data indicate that incorporation of serum ferritin level may improve the performance of noninvasive scoring of liver damage in patients with NAFLD,and that iron depletion still represents an attractive therapeutic target to prevent the progression of liver damage in these patients.展开更多
We report a theoretical scheme using a B-spline basis set to improve the poor computational accuracy of circular Rydberg states of hydrogen atoms in the intermediate magnetic field. This scheme can produce high accura...We report a theoretical scheme using a B-spline basis set to improve the poor computational accuracy of circular Rydberg states of hydrogen atoms in the intermediate magnetic field. This scheme can produce high accuracy energy levels and valid for an arbitrary magnetic field. Energy levels of hydrogen are presented for circular Rydberg states with azimuthal quantum numbers |m| =10-70 as a function of magnetic field strengths ranging from zero to 2.35 × 10^9 T. The variation of spatial distributions of electron probability densities with magnetic field strengths is discussed and competition between Coulomb and magnetic interactions is illustrated.展开更多
Calibration of magnetometer is an essential part to obtain high measurement precision.However,the existing calibration methods are basically the calibration of all attitudes,which means tough work when the magnetomete...Calibration of magnetometer is an essential part to obtain high measurement precision.However,the existing calibration methods are basically the calibration of all attitudes,which means tough work when the magnetometer is applied in strapdown inertial navigation system(SINS).So a quick,easy and effective calibration algorithm is developed based on the ellipsoid constraint to calibrate magnetometers.In this paper,the measuring principle and error characteristic of the magnetometer are analysed to study its magnetic interference.During the process,a magnetometer calibration model is set up to convert the calibration to ellipsoid fitting based on the characteristic of hard magnetic interference and soft magnetic interference.Then the algorithm is tested by mimic experiment.The result shows that measurement precision is improved after the calibration,and then the magnetometer is installed in a control cabin of an underwater robot which is designed and developed by us,and actual magnetometer calibration experiments are conducted to further verify the validity of the algorithm.展开更多
文摘Using the recently developed finite-basis-set method with B splines, excited states of H atoms in a magnetic field have been calculated. Energy levels are presented for the ten excited states, 2so, 3d'0, 3po, 3p-1, 3d_1, 4d-1, 3d-2, 4d-2, 4f-2 , and 5f-2 as a function of magnetic field strengths with a range from zero up to 2.35 × 10^6 T. The obtained results are compared with available high accuracy theoretical data reported in the literature and found to be in excellent agreement. The comparison also shows that the current method can produce energy levels with an accuracy higher than the existing high accuracy method [Phys. Rev. A 54 (1996) 287]. Here high accuracy energy levels are for the first time reported for the 3d'0, 4d-1, 4d-2, 4f-2, and 5f-2 states.
基金Supported by First Università degli Studi di Milano 2007,2008,to Valenti L and Fargion SRicerca corrente Ospedale Maggiore Policlinico 2006 and 2008,to Valenti L and FargionSCentro per lo Studio delle Malattie del Fegato e del Metabolismo
文摘Nonalcoholic fatty liver disease(NAFLD),defined by excessive liver fat deposition related to the metabolic syndrome,is a leading cause of progressive liver disease,for which accurate non-invasive staging systems and effective treatments are still lacking.Evidence has shown that increased ferritin levels are associated with the metabolic insulin resistance syndrome,and higher hepatic iron and fat content.Hyperferritinemia and iron stores have been associated with the severity of liver damage in NAFLD,and iron depletion reduced insulin resistance and liver enzymes.Recently,Kowdley et al demonstrated in a multicenter study in 628 adult patients with NAFLD from the NAFLD-clinical research network database with central re-evaluation of liver histology and iron staining that the increased serum ferritin level is an independent predictor of liver damage in patients with NAFLD,and is useful to identify NAFLD patients at risk of non-alcoholic steatohepatitis and advanced fibrosis.These data indicate that incorporation of serum ferritin level may improve the performance of noninvasive scoring of liver damage in patients with NAFLD,and that iron depletion still represents an attractive therapeutic target to prevent the progression of liver damage in these patients.
基金Support from National Science Foundation of USA under Grant No. 0630370National Natural Science Foundation of China under Grant Nos. 90403028 and 11074260
文摘We report a theoretical scheme using a B-spline basis set to improve the poor computational accuracy of circular Rydberg states of hydrogen atoms in the intermediate magnetic field. This scheme can produce high accuracy energy levels and valid for an arbitrary magnetic field. Energy levels of hydrogen are presented for circular Rydberg states with azimuthal quantum numbers |m| =10-70 as a function of magnetic field strengths ranging from zero to 2.35 × 10^9 T. The variation of spatial distributions of electron probability densities with magnetic field strengths is discussed and competition between Coulomb and magnetic interactions is illustrated.
基金Supported by the National High Technology Research and Development Programme of China(No.2011AA04201)
文摘Calibration of magnetometer is an essential part to obtain high measurement precision.However,the existing calibration methods are basically the calibration of all attitudes,which means tough work when the magnetometer is applied in strapdown inertial navigation system(SINS).So a quick,easy and effective calibration algorithm is developed based on the ellipsoid constraint to calibrate magnetometers.In this paper,the measuring principle and error characteristic of the magnetometer are analysed to study its magnetic interference.During the process,a magnetometer calibration model is set up to convert the calibration to ellipsoid fitting based on the characteristic of hard magnetic interference and soft magnetic interference.Then the algorithm is tested by mimic experiment.The result shows that measurement precision is improved after the calibration,and then the magnetometer is installed in a control cabin of an underwater robot which is designed and developed by us,and actual magnetometer calibration experiments are conducted to further verify the validity of the algorithm.