[ Objective] The study aimed to reveal the biological nitrogen fixation capacity by sugarcane from Brazil under the ecological conditions of Guangxi, and to provide reference for study on the biological nitrogen fixat...[ Objective] The study aimed to reveal the biological nitrogen fixation capacity by sugarcane from Brazil under the ecological conditions of Guangxi, and to provide reference for study on the biological nitrogen fixation capacity by sugarcane and related generalization and application. [ Method] The ^15N isotopic fertilizer was solely applied on plants of three sugarcane cultivars planted in greenhouse with no other fertilizer forms applied, meanwhile virus-free stem seedling was regarded as control, to measure their biological nitrogen fixation capacity using ^15N isotope. [ Result ] The nitrogen fixation rate of B8 from Brazil reached 26.91%, while Guitang 11 and RIC16 presented no or poor nitrogen fixation capacity. [ Conclusion] The sugarcane eultivar B8 from Brazil showed some nitrogen fixation capacity under the ecological conditions of Guangxi.展开更多
An NT-MT combined method based on nodal test (NT) and measurement test (MT) is developed for gross error detection and data reconciliation for industrial application. The NT-MT combined method makes use of both NT and...An NT-MT combined method based on nodal test (NT) and measurement test (MT) is developed for gross error detection and data reconciliation for industrial application. The NT-MT combined method makes use of both NT and MT tests and this combination helps to overcome the defects in the respective methods. It also avoids any artificial manipulation and eliminates the huge combinatorial problem that is created in the combined method based on the nodal test in the case of more than one gross error for a large process system. Serial compensation strategy is also used to avoid the decrease of the coefficient matrix rank during the computation of the proposed method. Simulation results show that the proposed method is very effective and possesses good performance.展开更多
This paper presents an experimental study of the physical characteristic effects of large particles on hydraulic transport in a horizontal pipe.The particles are spherical and are large with respect to the diameter of...This paper presents an experimental study of the physical characteristic effects of large particles on hydraulic transport in a horizontal pipe.The particles are spherical and are large with respect to the diameter of the pipe(8%,10%,16% and 25%).Experiments were done to test the important parameters in solid transport(pressure,velocity,etc.).As a result,the relationship between the pressure gradient forces and the mixture velocity was substantially different from the pure liquid flow.However,in a single-phase flow a monotonous behavior of the pressure drop curve is observed,and the curve of the solid particle flow attains its minimum at the critical velocity.The regimes are characterized with differential pressure measurements and visualizations.展开更多
The measurement accuracy of a wind tunnel balance is the key factor to improve the measurement accuracy for a test model in the wind tunnel. In order to improve the measurement accuracy of the wind tunnel balance, a g...The measurement accuracy of a wind tunnel balance is the key factor to improve the measurement accuracy for a test model in the wind tunnel. In order to improve the measurement accuracy of the wind tunnel balance, a great deal of investigation is carried out in China. This paper summarizes a program to improve the measurement accuracy of wind tunnel balances. In the program, the investigation is carried out in three aspects (1) designing a drag component of the balance in low interactions (2) choosing high quality foil strain gauges with temperature self-compensation (3) choosing the excellent gauges and mounting them meticulously. As an example, these research achievements are applied in a φ18 six component balance. The measurement accuracy of a GB-04 standard model in a transonic wind tunnel with the φ18 six component balance comes up to the advanced world standard.展开更多
The effects of trace element Fe on the corrosion behavior of AZ80 magnesium alloy were investigated by salt spray test and electrochemical measurements.The results show that the corrosion rate decreases with decreasin...The effects of trace element Fe on the corrosion behavior of AZ80 magnesium alloy were investigated by salt spray test and electrochemical measurements.The results show that the corrosion rate decreases with decreasing the trace element Fe content in an approximately linear relation even though the amount of trace element Fe reduces to 0.000 2%(mass fraction).The electrochemical measurements show that the corrosion potential(φcorr)of the alloy with lower trace element Fe content shifts to less negative value.It is suggested that the control trace element by purification is an effective way to enhance the corrosion resistance of AZ80 magnesium alloy.展开更多
Similarity measure construction has been proposed as fault detection of flight test method in order to obtain the primary control surface stuck and the combination stuck of primary control.Similarity measures were obt...Similarity measure construction has been proposed as fault detection of flight test method in order to obtain the primary control surface stuck and the combination stuck of primary control.Similarity measures were obtained through analyzing the certainty and uncertainty of fuzzy membership functions,which were designed based on well-known Hamming distance.It was applied to the fault detection of primary control surface stuck of uninhabited aerial vehicle(UAV).At post-failure control surface,if the UAV is controllable and trimmable using other control surfaces,the UAV is able to fly or return to the safety region through reconfiguration of flight control system.To detect the fault,similarity measure computations were carried out.This result could be applicable with the real-time parameter estimation method.By monitoring the value of coefficients due to the control surface deviation,it becomes aware that the control surface fault occurs or not.The control surface stuck position and value were separated by comparing the trim value with the reference value.This is the advantage of increasing in reliability without adding sensors or with additional low cost.展开更多
Thirteen specimens were tested out of which nine were for creep of sealed concrete and four for shrinkage test,for a period of 700 d under controlled temperature condition.The experimental results for creep and shrink...Thirteen specimens were tested out of which nine were for creep of sealed concrete and four for shrinkage test,for a period of 700 d under controlled temperature condition.The experimental results for creep and shrinkage were compared with creep and shrinkage computation model B3 and distinct discrepancies between observed and calculated creep and shrinkage strains were observed.Based on regression analysis,modification on B3 model has been formulated which will be applicable at least for concrete of characteristics strength of C40 and C50 with additives.Besides,on the basis of observation on identical specimens with varied stress strength ratio,a function is generated which accounts effect of stress strength ratio on creep.Finally,Civil Engineering community is suggested not to follow the creep prediction models without correction at least for modern concrete,as they do not account the effect of additives on its compliance function.展开更多
Toad red blood cells were used to measure regional bone blood flow in the canine mandibular ramus. The blood cells were labelled with sodium pertechnetate and fixed in 1 0%formalin; they were 22 × 15 μm in size ...Toad red blood cells were used to measure regional bone blood flow in the canine mandibular ramus. The blood cells were labelled with sodium pertechnetate and fixed in 1 0%formalin; they were 22 × 15 μm in size and had a specific gravity close to that of dog red blood cells. These cells had no discernible effect on systemic hemodynamics after injection, did not agglutinate, were well mixed and evenly distributed throughout the body, and were completely extracted in one circulation through the mandible. The mandibular ramus was divided into six regions. and the blood flow rates in each were found to be similar to those reported in previous studies with radiolabelled carbonized, microspheres. Furthermore, the blood flow distribution pattern of the mandibular ramus determined in this study was identical to that of our previous study using the bone-seeking radionuclide method. We suggest that radiolabelled toad red blood cells are an ideal marker for measuring regional blood flow in the canine mandible.展开更多
Heating the oil shale by current underground to accomplish in-situ transformation process, is a viable direction. The electrical properties of oil shale under different temperatures, especially the resistance, become ...Heating the oil shale by current underground to accomplish in-situ transformation process, is a viable direction. The electrical properties of oil shale under different temperatures, especially the resistance, become important. Charging oil shale underground to heat oil shale till kerogen's decomposition temperature, then crude oil and other gases can be generated. The resistance of the oil shale samples was measured by Direct Current (DC) quadripole method to find out the variation rules of resistance value. In the experiments, oil shale presented its semiconductor property. When heated till 350℃-450℃, its resistance changed greatly, optional for heating and cracking. The porosity, oil content, media and composition affected the resistance largely.展开更多
The inclining experiment is the only regulatory tool to assess ship stability. This experiment is a time consuming process for both real-life tests and ship model experiments. The difficulty is mainly due to a bias in...The inclining experiment is the only regulatory tool to assess ship stability. This experiment is a time consuming process for both real-life tests and ship model experiments. The difficulty is mainly due to a bias in the measurement of heel angle. Nowadays, digital inclinometers are available, but they are expensive. In this study, the use of a smartphone application is presented for ship inclination and rolling-period tests. The idea consists of using accelerometer and gyroscope sensors built into the current smartphones for the measurements. Therefore, some experiments are carried out on an example trawler model to exhibit the uses and advantages of this method. The obtained results are in good agreement with those provided from the pendulum method and natural roll-period test. This application is new, easy, and more accurately assesses metacentric height during the inclining and rolling-period tests.展开更多
Methods of exploitation drainage, which is presently applied in polish hard coal mines in Upper Silesian Coal Basin(Poland), are not effective enough, high risk of methane hazard can be observed, and production capaci...Methods of exploitation drainage, which is presently applied in polish hard coal mines in Upper Silesian Coal Basin(Poland), are not effective enough, high risk of methane hazard can be observed, and production capacity of the mining plant is not fully used. Methane hazard, which may occur during planned coal exploitation, is presented in this paper. Following parameters are taken into consideration in the forecasts: coal extraction parameters, geological and mining conditions, deposit's methane saturation degree and impact of coal exploitation on the degasification coefficient of the seams, which are under the influence of relaxation zone. This paper presents the results of the analysis aiming to verify applicability of drainage ahead of mining of the coal seams by using surface directional wells. Based on the collected data(coal seams' structural maps, profiles of the exploratory wells, geological cross-sections), the lab tests of drilling cores and direct wells' tests, static model of the deposit was constructed and suitable grid of directional wells from the surface was designed. Comparison of forecasted methane emission volume between the two methods is investigated. The results indicated the necessity of performing appropriate deposit's stimulations in order to increase effectiveness of drainage ahead of mining.展开更多
Validating a method of analysis goes through different steps, which aims at testing the normality of measurements distribution, estimating the uncertainty of the components of a measurement (i.e., accuracy and correc...Validating a method of analysis goes through different steps, which aims at testing the normality of measurements distribution, estimating the uncertainty of the components of a measurement (i.e., accuracy and correctness), and finally, define the control tests of non degradation of the method performances. This paper outlines the steps for validating a biological method of analysis. It involves the construction of an experimental design, a statistical model, and the preparation of an interne laboratory reference material (pilot vaccine). The latter is used to study the impact of deviation and variation factors, in order to, optimize the analytical method, to evaluate the bias (random error), and to calculate the uncertainty of measurement, and make the control charts. This method is applied in the titration of live viral vaccines of Gumboro disease on chicken's embryos fibroblasts. The experimental results show that potential influence factors related to the titration method had no significant influence on the obtained results. Taking into account these results, an operating mode has been elaborated. The finalized method proved to be faithful to standard deviation of repeatability and reproducibility of 0.21 and 0.22, respectively, with a confidence level of 95%. The calculated uncertainty of measurement is equal to 0.2, which represents the average error level of a titer. A homogeneous stock of interne laboratory reference vaccine (MRIL), with an average titer of 5.9 log DIT 50, was produced and the control chart set in away to provide the laboratory with an important tool of control and monitoring of the viral titers evolution in time, as well as, the mastery of the validated titration method performances.展开更多
This paper presents a lumped mass model to describe the run-out and velocity of a series of large flume tests,which was carried out to investigate some propagation mechanisms involved in rapid,dry,dense granular flows...This paper presents a lumped mass model to describe the run-out and velocity of a series of large flume tests,which was carried out to investigate some propagation mechanisms involved in rapid,dry,dense granular flows and energy transformation when the flows encountered obstacles and reoriented their movement directions.Comparisons between predicted and measured results show that the trend of predicted velocities was basically matched with that of measured ones.Careful scrutiny of test videos reveals that subsequent particles with a higher velocity collided with slowed fronts to make them accelerate. However,this simple model cannot reflect collisions between particles because it treated released materials as a rigid block.Thus,the predicted velocity was somewhat lower than the measured velocity in most cases.When the flow changed its direction due to the variation in slope inclination,the model predicted a decrease in velocity.The predicted decrease in velocity was less than the measured one within a reasonable range of 10% or less.For some cases in which a convexity was introduced,the model also predicted the same trend of velocities as measured in the tests.The velocity increased greatly after the materials took a ballistic trajectory from the vertex of the convexity,and reduced dramatically when they finally made contact with the base of the lower slope.The difference between prediced and measured decrease in velocity was estimated to be about 5% due to the landing.Therefore,the simple lumped mass model based on the energy approach could roughly predict the run-out and velocity of granular flows,although it neglected internal deformation,intergranular collision and friction.展开更多
In this paper, on the basis of the implementation of the national chemical industry standard analytical test methods and analysis of test items, a food additive quality analysis and inspection of network management ap...In this paper, on the basis of the implementation of the national chemical industry standard analytical test methods and analysis of test items, a food additive quality analysis and inspection of network management applications are developed using the development technology of Visual Basic language and computer system operating environment, to achieve a network management software for users on food additives of quality analytical testing. The software sets up an information sharing network platform for enterprise and quality management departments, which is a major innovation in the food additive quality analysis on test management methods and tools.展开更多
基金National Natural Science Foundation of China (3026005430660085)+1 种基金Key Project of Guangxi Academy of Agricultural Sciences (2004002)Natural Science Foundation in Guangxi Zhuang Autonomous Region (0639011)~~
文摘[ Objective] The study aimed to reveal the biological nitrogen fixation capacity by sugarcane from Brazil under the ecological conditions of Guangxi, and to provide reference for study on the biological nitrogen fixation capacity by sugarcane and related generalization and application. [ Method] The ^15N isotopic fertilizer was solely applied on plants of three sugarcane cultivars planted in greenhouse with no other fertilizer forms applied, meanwhile virus-free stem seedling was regarded as control, to measure their biological nitrogen fixation capacity using ^15N isotope. [ Result ] The nitrogen fixation rate of B8 from Brazil reached 26.91%, while Guitang 11 and RIC16 presented no or poor nitrogen fixation capacity. [ Conclusion] The sugarcane eultivar B8 from Brazil showed some nitrogen fixation capacity under the ecological conditions of Guangxi.
基金Supported by the National Creative Research Groups Science Foundation of China (No.60421002) and the National "TenthFive-Year" Science and Technology Research Program of China (2004BA204B08).
文摘An NT-MT combined method based on nodal test (NT) and measurement test (MT) is developed for gross error detection and data reconciliation for industrial application. The NT-MT combined method makes use of both NT and MT tests and this combination helps to overcome the defects in the respective methods. It also avoids any artificial manipulation and eliminates the huge combinatorial problem that is created in the combined method based on the nodal test in the case of more than one gross error for a large process system. Serial compensation strategy is also used to avoid the decrease of the coefficient matrix rank during the computation of the proposed method. Simulation results show that the proposed method is very effective and possesses good performance.
基金the Dyn Fluid Laboratory at Arts et Métiers Paris Tech
文摘This paper presents an experimental study of the physical characteristic effects of large particles on hydraulic transport in a horizontal pipe.The particles are spherical and are large with respect to the diameter of the pipe(8%,10%,16% and 25%).Experiments were done to test the important parameters in solid transport(pressure,velocity,etc.).As a result,the relationship between the pressure gradient forces and the mixture velocity was substantially different from the pure liquid flow.However,in a single-phase flow a monotonous behavior of the pressure drop curve is observed,and the curve of the solid particle flow attains its minimum at the critical velocity.The regimes are characterized with differential pressure measurements and visualizations.
文摘The measurement accuracy of a wind tunnel balance is the key factor to improve the measurement accuracy for a test model in the wind tunnel. In order to improve the measurement accuracy of the wind tunnel balance, a great deal of investigation is carried out in China. This paper summarizes a program to improve the measurement accuracy of wind tunnel balances. In the program, the investigation is carried out in three aspects (1) designing a drag component of the balance in low interactions (2) choosing high quality foil strain gauges with temperature self-compensation (3) choosing the excellent gauges and mounting them meticulously. As an example, these research achievements are applied in a φ18 six component balance. The measurement accuracy of a GB-04 standard model in a transonic wind tunnel with the φ18 six component balance comes up to the advanced world standard.
基金Project(2007CB613705)supported by the National Basic Research Program of China
文摘The effects of trace element Fe on the corrosion behavior of AZ80 magnesium alloy were investigated by salt spray test and electrochemical measurements.The results show that the corrosion rate decreases with decreasing the trace element Fe content in an approximately linear relation even though the amount of trace element Fe reduces to 0.000 2%(mass fraction).The electrochemical measurements show that the corrosion potential(φcorr)of the alloy with lower trace element Fe content shifts to less negative value.It is suggested that the control trace element by purification is an effective way to enhance the corrosion resistance of AZ80 magnesium alloy.
基金Project(20110018394) supported by Key Research Institute Program through the National Research Foundation (NRF) of Korea
文摘Similarity measure construction has been proposed as fault detection of flight test method in order to obtain the primary control surface stuck and the combination stuck of primary control.Similarity measures were obtained through analyzing the certainty and uncertainty of fuzzy membership functions,which were designed based on well-known Hamming distance.It was applied to the fault detection of primary control surface stuck of uninhabited aerial vehicle(UAV).At post-failure control surface,if the UAV is controllable and trimmable using other control surfaces,the UAV is able to fly or return to the safety region through reconfiguration of flight control system.To detect the fault,similarity measure computations were carried out.This result could be applicable with the real-time parameter estimation method.By monitoring the value of coefficients due to the control surface deviation,it becomes aware that the control surface fault occurs or not.The control surface stuck position and value were separated by comparing the trim value with the reference value.This is the advantage of increasing in reliability without adding sensors or with additional low cost.
文摘Thirteen specimens were tested out of which nine were for creep of sealed concrete and four for shrinkage test,for a period of 700 d under controlled temperature condition.The experimental results for creep and shrinkage were compared with creep and shrinkage computation model B3 and distinct discrepancies between observed and calculated creep and shrinkage strains were observed.Based on regression analysis,modification on B3 model has been formulated which will be applicable at least for concrete of characteristics strength of C40 and C50 with additives.Besides,on the basis of observation on identical specimens with varied stress strength ratio,a function is generated which accounts effect of stress strength ratio on creep.Finally,Civil Engineering community is suggested not to follow the creep prediction models without correction at least for modern concrete,as they do not account the effect of additives on its compliance function.
文摘Toad red blood cells were used to measure regional bone blood flow in the canine mandibular ramus. The blood cells were labelled with sodium pertechnetate and fixed in 1 0%formalin; they were 22 × 15 μm in size and had a specific gravity close to that of dog red blood cells. These cells had no discernible effect on systemic hemodynamics after injection, did not agglutinate, were well mixed and evenly distributed throughout the body, and were completely extracted in one circulation through the mandible. The mandibular ramus was divided into six regions. and the blood flow rates in each were found to be similar to those reported in previous studies with radiolabelled carbonized, microspheres. Furthermore, the blood flow distribution pattern of the mandibular ramus determined in this study was identical to that of our previous study using the bone-seeking radionuclide method. We suggest that radiolabelled toad red blood cells are an ideal marker for measuring regional blood flow in the canine mandible.
文摘Heating the oil shale by current underground to accomplish in-situ transformation process, is a viable direction. The electrical properties of oil shale under different temperatures, especially the resistance, become important. Charging oil shale underground to heat oil shale till kerogen's decomposition temperature, then crude oil and other gases can be generated. The resistance of the oil shale samples was measured by Direct Current (DC) quadripole method to find out the variation rules of resistance value. In the experiments, oil shale presented its semiconductor property. When heated till 350℃-450℃, its resistance changed greatly, optional for heating and cracking. The porosity, oil content, media and composition affected the resistance largely.
文摘The inclining experiment is the only regulatory tool to assess ship stability. This experiment is a time consuming process for both real-life tests and ship model experiments. The difficulty is mainly due to a bias in the measurement of heel angle. Nowadays, digital inclinometers are available, but they are expensive. In this study, the use of a smartphone application is presented for ship inclination and rolling-period tests. The idea consists of using accelerometer and gyroscope sensors built into the current smartphones for the measurements. Therefore, some experiments are carried out on an example trawler model to exhibit the uses and advantages of this method. The obtained results are in good agreement with those provided from the pendulum method and natural roll-period test. This application is new, easy, and more accurately assesses metacentric height during the inclining and rolling-period tests.
文摘Methods of exploitation drainage, which is presently applied in polish hard coal mines in Upper Silesian Coal Basin(Poland), are not effective enough, high risk of methane hazard can be observed, and production capacity of the mining plant is not fully used. Methane hazard, which may occur during planned coal exploitation, is presented in this paper. Following parameters are taken into consideration in the forecasts: coal extraction parameters, geological and mining conditions, deposit's methane saturation degree and impact of coal exploitation on the degasification coefficient of the seams, which are under the influence of relaxation zone. This paper presents the results of the analysis aiming to verify applicability of drainage ahead of mining of the coal seams by using surface directional wells. Based on the collected data(coal seams' structural maps, profiles of the exploratory wells, geological cross-sections), the lab tests of drilling cores and direct wells' tests, static model of the deposit was constructed and suitable grid of directional wells from the surface was designed. Comparison of forecasted methane emission volume between the two methods is investigated. The results indicated the necessity of performing appropriate deposit's stimulations in order to increase effectiveness of drainage ahead of mining.
文摘Validating a method of analysis goes through different steps, which aims at testing the normality of measurements distribution, estimating the uncertainty of the components of a measurement (i.e., accuracy and correctness), and finally, define the control tests of non degradation of the method performances. This paper outlines the steps for validating a biological method of analysis. It involves the construction of an experimental design, a statistical model, and the preparation of an interne laboratory reference material (pilot vaccine). The latter is used to study the impact of deviation and variation factors, in order to, optimize the analytical method, to evaluate the bias (random error), and to calculate the uncertainty of measurement, and make the control charts. This method is applied in the titration of live viral vaccines of Gumboro disease on chicken's embryos fibroblasts. The experimental results show that potential influence factors related to the titration method had no significant influence on the obtained results. Taking into account these results, an operating mode has been elaborated. The finalized method proved to be faithful to standard deviation of repeatability and reproducibility of 0.21 and 0.22, respectively, with a confidence level of 95%. The calculated uncertainty of measurement is equal to 0.2, which represents the average error level of a titer. A homogeneous stock of interne laboratory reference vaccine (MRIL), with an average titer of 5.9 log DIT 50, was produced and the control chart set in away to provide the laboratory with an important tool of control and monitoring of the viral titers evolution in time, as well as, the mastery of the validated titration method performances.
基金supported by theopen fund project of Scientific Alleviation of Disasters and Home Rebuilding(Grant No.DZJK-0814)from the Chinese State Key Laboratory of Geohazard Prevention and Geoenvironment Protection,Chengdu University of Technology
文摘This paper presents a lumped mass model to describe the run-out and velocity of a series of large flume tests,which was carried out to investigate some propagation mechanisms involved in rapid,dry,dense granular flows and energy transformation when the flows encountered obstacles and reoriented their movement directions.Comparisons between predicted and measured results show that the trend of predicted velocities was basically matched with that of measured ones.Careful scrutiny of test videos reveals that subsequent particles with a higher velocity collided with slowed fronts to make them accelerate. However,this simple model cannot reflect collisions between particles because it treated released materials as a rigid block.Thus,the predicted velocity was somewhat lower than the measured velocity in most cases.When the flow changed its direction due to the variation in slope inclination,the model predicted a decrease in velocity.The predicted decrease in velocity was less than the measured one within a reasonable range of 10% or less.For some cases in which a convexity was introduced,the model also predicted the same trend of velocities as measured in the tests.The velocity increased greatly after the materials took a ballistic trajectory from the vertex of the convexity,and reduced dramatically when they finally made contact with the base of the lower slope.The difference between prediced and measured decrease in velocity was estimated to be about 5% due to the landing.Therefore,the simple lumped mass model based on the energy approach could roughly predict the run-out and velocity of granular flows,although it neglected internal deformation,intergranular collision and friction.
文摘In this paper, on the basis of the implementation of the national chemical industry standard analytical test methods and analysis of test items, a food additive quality analysis and inspection of network management applications are developed using the development technology of Visual Basic language and computer system operating environment, to achieve a network management software for users on food additives of quality analytical testing. The software sets up an information sharing network platform for enterprise and quality management departments, which is a major innovation in the food additive quality analysis on test management methods and tools.