期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
基于银增强金标记物的阳极溶出伏安免疫分析用于补体第三成分的测定 被引量:6
1
作者 楚霞 傅昕 +1 位作者 沈国励 俞汝勤 《高等学校化学学报》 SCIE EI CAS CSCD 北大核心 2005年第9期1637-1639,共3页
A novel, sensitive anodic stripping volammetric immunoassay was developed based on silver-enhanced immuno-gold label. The immunoreaction was performed in a polystyrene microwell by using the sandwich format. Primary a... A novel, sensitive anodic stripping volammetric immunoassay was developed based on silver-enhanced immuno-gold label. The immunoreaction was performed in a polystyrene microwell by using the sandwich format. Primary antibodies specific for C-3(complement Ⅲ) were adsorbed passively on the walls of a polystyrene microwell. The C-3 analyte was first captured by the primary antibody and then sandwiched by a secondary colloidal gold-labeled antibody. The addition of the silver enhancement solution results in the precipitation of a large amount of silver on colloidal gold labels due to the catalytic reduction which, after silver metal dissolution in an acidic solution, was determined by anodic stripping voltammetry(ASV) at a glassy-carbon electrode. The influence of some immunoassay conditions upon the anodic stripping peak current was examined and optimized. The anodic stripping peak current depended linearly on the logarithm of C-3 mass concentration over the range of 7.2 ng/mL to 7.33 μg/mL and a detection limit as low as 7ng/mL is achieved. The anodic stripping volammetric immunoassay was applied to the determination of C-3 concentration in human serum with satisfactory results. 展开更多
关键词 金属免疫分析 阳极溶出伏安法 银增强溶液 免疫金标记物
下载PDF
基于铜增强纳米金标记物结合磁分离的溶出伏安免疫分析法用于蛋白质的高灵敏测定 被引量:3
2
作者 沈广宇 冯辉 郝爱平 《高等学校化学学报》 SCIE EI CAS CSCD 北大核心 2009年第5期886-890,共5页
应用铜原位化学放大纳米金颗粒的信号增强特性,并结合磁分离技术,提出了一种高灵敏的溶出伏安免疫分析方法.实验中以人IgG为模式蛋白质,将抗体修饰的SiO2@Fe3O4核壳型磁性纳米颗粒和纳米金标抗体悬浊液混合,用以均相免疫识别人IgG,借助... 应用铜原位化学放大纳米金颗粒的信号增强特性,并结合磁分离技术,提出了一种高灵敏的溶出伏安免疫分析方法.实验中以人IgG为模式蛋白质,将抗体修饰的SiO2@Fe3O4核壳型磁性纳米颗粒和纳米金标抗体悬浊液混合,用以均相免疫识别人IgG,借助外加磁场分离纯化,在免疫复合物悬浊液中加入铜增强试剂进行沉积放大反应,再将铜用稀硝酸溶解并进行溶出伏安分析检测.结果表明,与基于固相反应的金属免疫分析法相比,所提出的基于均相反应和磁分离原理的方法具有操作简单、分析时间短等优点.该方法显示出明显增强的人IgG检测性能,其线性检测范围为0.1~1000 ng/mL,检出限为73 pg/mL.此外,将其用于实际样品的回收率测定,结果令人满意. 展开更多
关键词 纳米金 铜增强信号放大 磁分离 金属免疫分析
下载PDF
基于胶体金标记的阳极溶出伏安免疫分析用于免疫球蛋白G的测定 被引量:6
3
作者 楚霞 向知峰 +1 位作者 沈国励 俞汝勤 《分析科学学报》 CAS CSCD 2006年第5期497-500,共4页
提出了一种基于胶体金标记的阳极溶出伏安免疫分析方法。免疫反应在聚苯乙烯微孔板中以夹心分析模式进行,通过物理吸附将兔抗人免疫球蛋白G(IgG)抗体固定于微孔板上,与相应抗原IgG发生免疫反应后,再通过夹心模式捕获相应的纳米金... 提出了一种基于胶体金标记的阳极溶出伏安免疫分析方法。免疫反应在聚苯乙烯微孔板中以夹心分析模式进行,通过物理吸附将兔抗人免疫球蛋白G(IgG)抗体固定于微孔板上,与相应抗原IgG发生免疫反应后,再通过夹心模式捕获相应的纳米金标记的羊抗人IgG抗体,然后再与金标羊抗人IgG抗体和金标兔抗羊二抗形成的免疫复合物反应,在微孔板上进一步引入大量的纳米金,将金溶解后,在碳糊电极上用阳极溶出伏安法(ASV)对金离子进行检测,溶出峰电流的大小间接与待分析物IgG的浓度成正比。对免疫分析的一些实验条件进行了优化。阳极溶出峰电流与IgG的对数浓度在1.1~1143ng/mL范围内呈良好的线性关系,检出限为1ng/mL。将该方法应用于人血清中IgG浓度的测定,取得了满意结果。 展开更多
关键词 金属免疫分析 阳极溶出伏安法 胶体金标记 免疫球蛋白G
下载PDF
Metal sulfide quantum dots-aggregated PAMAM dendrimer for cadmium ion-selective electrode-based immunoassay of alpha-fetoprotein 被引量:2
4
作者 Qunfang Li Jing Jin +1 位作者 Fangming Lou Dianping Tang 《Science China Chemistry》 SCIE EI CAS CSCD 2018年第6期750-756,共7页
An ion-selective electrode(ISE)-based immunoassay has been innovatively designed for the sensitive detection of liver cancer biomarker(alpha-fetoprotein,AFP),using metal sulfide quantum dot(QD)-based nano labels.Cd S ... An ion-selective electrode(ISE)-based immunoassay has been innovatively designed for the sensitive detection of liver cancer biomarker(alpha-fetoprotein,AFP),using metal sulfide quantum dot(QD)-based nano labels.Cd S QDs-aggregated PAMAM dendrimer(QD-DE)was first synthesized and functionalized with polyclonal rabbit anti-human AFP antibodies.Thereafter,a sandwich immunoreaction was implemented on monoclonal mouse anti-human AFP antibody-coated microplate by using antibody-functionalized QD-DE as the secondary antibody.Accompanying the immunocomplex,subsequent potentiometric detection of cadmium ion dissolved from the QD-DE under acidic condition was conducted on a portable cadmium ion-selective electrode(Cd-ISE).Results revealed that the electrode potential of the Cd-ISE increased with the increment of AFP concentration from 0.1 to 100 ng m L^(-1)at a detection limit(LOD)of 68 pg m L^(-1).The relative standard deviations(RSD)were below9.09%and 10.54%for the intra-and inter-assay,respectively.Additionally,six human serum specimens were determined on CdISE-based immunosensor by using commercial human AFP ELISA kit as the reference,and gave good relationship between two methods.Importantly,Cd-ISE-based immunoassay offers the promise for simple and cost-effective screening of disease-related biomarkers. 展开更多
关键词 potentiometric immunoassay metal sulfide quantum dot PAMAM dendrimer ALPHA-FETOPROTEIN ion-selective electrode cancer biomarker
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部