AIM: Esophageal squamous cell carcinoma is generally sensitive to chemoradiotherapy (CRT), but some cases are not. Using a retrospective analysis, we aimed to identify the predictors of the response by esophageal s...AIM: Esophageal squamous cell carcinoma is generally sensitive to chemoradiotherapy (CRT), but some cases are not. Using a retrospective analysis, we aimed to identify the predictors of the response by esophageal squamous cell carcinoma to definitive CRT. METHODS: The intensities of expression of p53, Ki67, Bci-2, Bax, olclin D1, VEGF, CDC25B, and metallothionein (MT) were evaluated immunohistochemically in the biopsy specimens obtained before CRT, and the intensities of their expression were tested for correlations with the clinical effects of CRT. RESULTS: The esophageal squamous cell carcinomas with negative p53, positive CDC25B, and negative MT expression were found to be significantly more sensitive to CRT. In addition, p53 positivity and CDC25B positivity respomd well to CRT. CONCLUSION: Esophageal squamous cell carcinomas with negative p53,positive CDC25B, and negative MT expressions respond well to CRT. Even with p53 positivity, if with CDC25B positivity, CRT can be expected. 2005 The WJG Press and Elsevier Inc. All rights reserved展开更多
This study aimed to evaluate the feasibility and safety of a novel stent manufactured by metal injection molding(MIM)in clinical practice through animal experiments.Vessel stents were prepared using powder injection m...This study aimed to evaluate the feasibility and safety of a novel stent manufactured by metal injection molding(MIM)in clinical practice through animal experiments.Vessel stents were prepared using powder injection molding technology to considerably improve material utilization.The influence of MIM carbon impurity variation on the mechanical properties and corrosion resistance of 316L stainless steel was studied.In vitro cytotoxicity and animal transplantation tests were also carried out to evaluate the safety of MIM stents.The results showed that the performance of 316L stainless steel was very sensitive to the carbon content.Carbon fluctuations should be precisely controlled during MIM.All MIM stents were successfully implanted into the aortas of the dogs,and the MIM 316L stents had no significant cytotoxicity.The novel intravascular stent manufactured using MIM can maintain a stable form and structure with fast endothelialization of the luminal surface of the stent and ensure long-term patency in an animal model.The novel intravascular stent manufactured using MIM demonstrates favorable structural,physical,and chemical stability,as well as biocompatibility,offering promising application in clinical practice.展开更多
文摘AIM: Esophageal squamous cell carcinoma is generally sensitive to chemoradiotherapy (CRT), but some cases are not. Using a retrospective analysis, we aimed to identify the predictors of the response by esophageal squamous cell carcinoma to definitive CRT. METHODS: The intensities of expression of p53, Ki67, Bci-2, Bax, olclin D1, VEGF, CDC25B, and metallothionein (MT) were evaluated immunohistochemically in the biopsy specimens obtained before CRT, and the intensities of their expression were tested for correlations with the clinical effects of CRT. RESULTS: The esophageal squamous cell carcinomas with negative p53, positive CDC25B, and negative MT expression were found to be significantly more sensitive to CRT. In addition, p53 positivity and CDC25B positivity respomd well to CRT. CONCLUSION: Esophageal squamous cell carcinomas with negative p53,positive CDC25B, and negative MT expressions respond well to CRT. Even with p53 positivity, if with CDC25B positivity, CRT can be expected. 2005 The WJG Press and Elsevier Inc. All rights reserved
基金the Major Project of the Ministry of Science and Technology of Changsha,China(No.kh2003014)the Hunan Provincial Natural Science Foundation,China(Nos.2018JJ2584,2018JJ3507)+1 种基金the Beijing Municipal Science and Technology Comission,China(No.D171100002917004)the Guangxi Science and Technology Plan Project,China(No.AD16380019).
文摘This study aimed to evaluate the feasibility and safety of a novel stent manufactured by metal injection molding(MIM)in clinical practice through animal experiments.Vessel stents were prepared using powder injection molding technology to considerably improve material utilization.The influence of MIM carbon impurity variation on the mechanical properties and corrosion resistance of 316L stainless steel was studied.In vitro cytotoxicity and animal transplantation tests were also carried out to evaluate the safety of MIM stents.The results showed that the performance of 316L stainless steel was very sensitive to the carbon content.Carbon fluctuations should be precisely controlled during MIM.All MIM stents were successfully implanted into the aortas of the dogs,and the MIM 316L stents had no significant cytotoxicity.The novel intravascular stent manufactured using MIM can maintain a stable form and structure with fast endothelialization of the luminal surface of the stent and ensure long-term patency in an animal model.The novel intravascular stent manufactured using MIM demonstrates favorable structural,physical,and chemical stability,as well as biocompatibility,offering promising application in clinical practice.
基金National Natural Science Foundation of China(51202196)Northwestern Polytechnical University(NPU)Foundation for Fundamental Research(JC201111)+1 种基金Research Fund of the State Key Laboratory of Solidification Processing(NWPU)(58-TZ-2011)"111"Project(B08040)