期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
对不锈钢及其复合板用于水工钢结构的探讨
1
作者 张志修 乔裕民 +1 位作者 吴尚明 毕士君 《石油化工建设》 2012年第4期72-74,共3页
专题分析了水工钢结构中使用不锈钢及其复合板的盲目性和危害性;根据不锈钢的种类,指出水利工程的总体设计可采用的不锈钢类型及选用原则。
关键词 不锈 复合板 钝化钢 电偶腐蚀 有效面积 系统工程
下载PDF
不利环境下钢筒混凝土管道的保护
2
作者 孙瑞君 《科技情报开发与经济》 2005年第23期285-286,共2页
介绍了钢筒混凝土管道的结构类型及特性,对几种常见的对钢筒混凝土管道不利的环境因素进行了分析,并针对不利环境条件下所应采取的保护措施做了阐述。
关键词 输水工程 筒混凝土管道 不利环境 构件 电阻率
下载PDF
Electrochemical study on semiconductive properties of the passive film on rebar in concrete 被引量:4
3
作者 ZHANG Yun-lian LI Qi-ling 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2006年第8期1447-1452,共6页
The electrochemical behavior of metallic passive film on rebar in concrete is characterized by its semiconductive nature. The charge distribution at the interface between a semiconductor and an electrolyte is often de... The electrochemical behavior of metallic passive film on rebar in concrete is characterized by its semiconductive nature. The charge distribution at the interface between a semiconductor and an electrolyte is often determined by measuring the capacitance of the space-charge layer (Csc) as a function of the electrode potential (E). When the space charge-layer serves as the depletion layer, the relation of Csc^-2 vs E resembles a Mott-Schottky plot (M-S plot). The semiconductive properties of the passive film on rebar in concrete were analyzed with M-S plots to study the effect of chloride ions and mineral admixtures on rebar passive films. Some rebar electrodes were immersed in simulated concrete pore solutions, while others were embedded in concrete with/without mineral admixtures. In saturated Ca(OH), solutions, the relation of Csc^-2-E of rebar electrodes shows linear MottSchottky relationship indicating that the passive film on rebar is a highly disordered n-type semiconductor, with donor density (ND) in the order of 10^26m^-3. After adding chloride ions (Cl wt%〈0.2%) in system solutions, the M-S plot slopes significantly decreased and ND increased, suggesting that chloride ion will cause passive film corrosion and breakdown. The M-S plots of the passive film on rebar electrodes embedded in concrete were similar to those immersed in simulated system solution. However, ND of those in concrete with mineral admixtures tended to be a little smaller, indicating that introducing proper quantity admixtures into concrete could make the rebar passive film have a thicker space-charge layer and therefore a thicker passive film layer. 展开更多
关键词 Mott-Schottky (M-S) Plot Rebar electrode. Passive film Simulated concrete pore solution Mineral admixture
下载PDF
Corrosion Study and Passive Film Characterization of 11% Cr FIM and 15% Cr ODS Steels
4
作者 Masatoshi Sakairi Sublime Ningshen +1 位作者 Keita Suzuki Shigeharu Ukai 《Journal of Civil Engineering and Architecture》 2013年第8期940-955,共16页
An ODS (oxide dispersion strengthened) steels are one of the most notable structural materials being developed for future high-temperature energy production technologies, and several studies have been devoted to the... An ODS (oxide dispersion strengthened) steels are one of the most notable structural materials being developed for future high-temperature energy production technologies, and several studies have been devoted to the development of ODS materials for such applications. However, only little paper focuses on corrosion behavior of F/M (ferritic martensictic) and ODS steels. The corrosion behavior of 11% Cr F/M steel and 15% Cr ODS steel were evaluated using electrochemical methods in borate buffer and 1 kmol m"3 HNO3 with or without NaCI and also in boiling 60% nitric acid. The corrosion resistance results clearly indicated the influences of steel alloys composition and chloride ions. The XPS (X-ray photo-electron spectroscopy) results of the pre-passivated surface revealed that the oxide formed were composed predominantly of Fe203 along with Cr203, and Y203 layers in ODS steel. The corrosion rate measured in boiling nitric acid for 48 h for both the steels shows high corrosion rate in boiling condition. The SEM (scanning electron microscopy) observation of the pit morphology after corrosion tests appears with shallow pit in both steel surfaces The corrosion degradation behavior in relation to the composition of the passive oxide film in different electrolytic solutions is discussed in this paper. 展开更多
关键词 F/M steel ODS steel CORROSION passive film XPS analysis.
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部