In present paper application of Endurance Time Analysis (ETA) method in nonlinear seismic assessment of steel concentrically braced frames is studied. In this method structure is subjected to a set of predesigned in...In present paper application of Endurance Time Analysis (ETA) method in nonlinear seismic assessment of steel concentrically braced frames is studied. In this method structure is subjected to a set of predesigned increasing acceleration functions and various responses of the structure are recorded during synthetic seismic excitation. The averages of maximum values for various responses in Nonlinear Time-History Analyses (NTHA) extracted from real ground motions are expected to be close to those obtained from ETA up to equivalent target time. For this purpose a set of 9, 11, 13 and 15 stories steel frames were designed and plastic hinge method was selected as source of nonlinearity in all cases. Responses were compared based on interstory drift ratio and story shear in two methods and results show satisfactory consistency between two methods. Finally, it was concluded that the ETA method can be used as alternative method in nonlinear seismic analysis of concentrically braced steel frames.展开更多
The research presented in this paper deals with the seismic protection of existing frame structures by means of passive energy dissipation. An iterative displacement-based procedure, based on capacity spectrum, to des...The research presented in this paper deals with the seismic protection of existing frame structures by means of passive energy dissipation. An iterative displacement-based procedure, based on capacity spectrum, to design dissipative bracings for seismic retrofitting of the frame structures is described, and some applications are discussed. The procedure can be used with any typology of dissipative device and for different performance targets. In this work, the procedure has been applied, with both traditional pushover (load profile proportional to first mode) and multimodal pushover, to an existing RC (reinforced concrete) frame building. In the application, the buckling restrained braces have been used in order to prevent damages to both the structure and non structural elements. The use of multimodal pushover proves to be more effective than pushover based on single mode in case of medium rise RC frame building (higher than 30 m) but, once this building is retrofitted, and therefore regularized, with a bracing system, the difference between using monomodal or multimodal pushover becomes insignificant.展开更多
文摘In present paper application of Endurance Time Analysis (ETA) method in nonlinear seismic assessment of steel concentrically braced frames is studied. In this method structure is subjected to a set of predesigned increasing acceleration functions and various responses of the structure are recorded during synthetic seismic excitation. The averages of maximum values for various responses in Nonlinear Time-History Analyses (NTHA) extracted from real ground motions are expected to be close to those obtained from ETA up to equivalent target time. For this purpose a set of 9, 11, 13 and 15 stories steel frames were designed and plastic hinge method was selected as source of nonlinearity in all cases. Responses were compared based on interstory drift ratio and story shear in two methods and results show satisfactory consistency between two methods. Finally, it was concluded that the ETA method can be used as alternative method in nonlinear seismic analysis of concentrically braced steel frames.
文摘The research presented in this paper deals with the seismic protection of existing frame structures by means of passive energy dissipation. An iterative displacement-based procedure, based on capacity spectrum, to design dissipative bracings for seismic retrofitting of the frame structures is described, and some applications are discussed. The procedure can be used with any typology of dissipative device and for different performance targets. In this work, the procedure has been applied, with both traditional pushover (load profile proportional to first mode) and multimodal pushover, to an existing RC (reinforced concrete) frame building. In the application, the buckling restrained braces have been used in order to prevent damages to both the structure and non structural elements. The use of multimodal pushover proves to be more effective than pushover based on single mode in case of medium rise RC frame building (higher than 30 m) but, once this building is retrofitted, and therefore regularized, with a bracing system, the difference between using monomodal or multimodal pushover becomes insignificant.