港湾码头钢构筑物的防护方法
1
作者 李希诚 《金山油化纤》 1994年第3期66-68,共3页
港湾码头钢构筑物,特别是其潮差、飞溅部分由于处在复杂严酷的条件下工作遭受到严重的腐蚀,因此,必须采用有效的防护方法,以确保和延长钢构筑物的使用年限.
关键词 钢构筑物 防腐 码头 港口 水工建筑物
下载PDF
大深度地下挖掘技术的现状与动向
2
《市政工程国外动态》 2004年第2期33-33,共1页
关键词 混凝土 钢构筑物 无损检查 龟裂 腐蚀
下载PDF
Shear strengthening of pre-damaged reinforced concrete beams with carbon fiber reinforced polymer sheet strips
3
作者 Feras ALZOUBI 《Journal of Chongqing University》 CAS 2007年第4期305-310,共6页
This paper presents the results of an experimental investigation on the response of pre-damaged reinforced concrete (RC) beam strengthened in shear using applied-epoxy unidirectional carbon fiber reinforced polymer ... This paper presents the results of an experimental investigation on the response of pre-damaged reinforced concrete (RC) beam strengthened in shear using applied-epoxy unidirectional carbon fiber reinforced polymer (CFRP) sheet. The reasearch included four test rectangular simply supported RC beams in shear capacity. One is the control beam, two RC beams are damaged to a predetermined degree from ultimate shear capacity of the control beam, and the last beam is left without pre-damaged and then strengthened with using externally bonded carbon fiber reinforced polymer to upgrade their shear capacity. We focused on the damage degree to beams during strengthening, therefore, only the beams with sidebonded CFRPs strips and horizontal anchored strips were used. The results show the feasibility of using CFRPs to restore or increase the load-carrying capacity in the shear of damaged RC beams. The failure mode of all the CFRP-strengthened beams is debonding of CFRP vertical strips. Two prediction available models in AC1-440 and fib European code were compared with the experimental results. 展开更多
关键词 reinforced concrete beam carbon fiber reinforced polymer shear strength
下载PDF
Seismic Safety of RC Framed Buildings Designed According to Modern Codes
4
作者 Juan Carlos Vielma Barbat Alex Oiler Sergio 《Journal of Civil Engineering and Architecture》 2011年第7期567-575,共9页
In order to ensure that a structure does not collapse when subjected to the action of strong ground motions, modern codes include prescriptions in order to guarantee the ductile behavior of the elements and of the who... In order to ensure that a structure does not collapse when subjected to the action of strong ground motions, modern codes include prescriptions in order to guarantee the ductile behavior of the elements and of the whole structure. Obviously, it would be of special importance for the designer to know during the design process the extent of damage that the structure will suffer under the seismic action specified by the design spectrum and also the probability of occurrence of different states of behavior. The incremental nonlinear static analysis procedure used in this paper allows formulating a new, simplified, seismic damage index and damage thresholds associated with five limit states. The seismic behavior of a set of regular reinforced concrete buildings designed according to the EC-2/EC-8 prescriptions for a high seismic hazard level is then studied using the proposed damage index and damage states. Fragility curves and damage probability matrices corresponding to the performance point are calculated for the studied buildings. The obtained results show that the collapse damage state is not reached in the buildings designed according to the prescriptions of EC-2/EC-8 and also that the damage does not exceed the irreparable damage limit state. 展开更多
关键词 Non linear analysis limit states OVERSTRENGTH DUCTILITY redundancy.