This article aims to present an analysis of the influence of thermal bridges on reinforced concrete structural systems regarding energy performance of the envelope of a commercial building located in the bioclimatic z...This article aims to present an analysis of the influence of thermal bridges on reinforced concrete structural systems regarding energy performance of the envelope of a commercial building located in the bioclimatic zones 1 to 8 in Brazil, using computer simulation. The method used to achieve this goal includes the following steps: (1) definition and configuration of the base case; (2) definition and configuration of the reference model; (3) optimization of energy modeling; (4) energy modeling and comparison of consumption between the base case and the reference model. Main results showed that thermal bridges in reinforced concrete interfere on the building's energy performance and that the impact is related to the WWR (window-to-wall ratio) on the building. For hotel buildings with WWR from 30% to 45%, thermal bridges imply a decrease in estimated consumption, which can reach 10%, depending on the bioclimatic zone. For 60% WWR, the non-consideration of thermal bridges can represent up to 5% of increase in estimated consumption, depending on the Brazilian bioclimatic zone.展开更多
Illyria hotel (formerly Bozhur) was built during the sixties in the heart of the actual Kosovo's capital Prishtina, according to former old Yugoslav standards in a Modernist architectural style. It represents a mas...Illyria hotel (formerly Bozhur) was built during the sixties in the heart of the actual Kosovo's capital Prishtina, according to former old Yugoslav standards in a Modernist architectural style. It represents a massive structural system with brick walls up to 54 cm thick and "avramenko" type reinforced concrete floors. The investor's aim was to add another two floors on the top of the existing ones and to build two level underground parking floors, a health spa centre, whilst at the vicinity of the existing building (the northern side) to erect a new 17 story-high brand new hotel and administration building. The retrofitting of the structure as well as construction of the new structure has been done in full accordance with the new structural Eurocodes' recommendations. 3D FEM (finite element method) modeling was used for the analysis and design, using ETABS v 9.5 nonlinear and ARSAP 2010 (Autodesk Robot Structural Analysis Professional 2010). Response spectrum design according to EC 8,3.2.2.4 has been used for seismic analysis and design with a reference peak ground acceleration on type A ground Of AgR = 0.25 g.展开更多
文摘This article aims to present an analysis of the influence of thermal bridges on reinforced concrete structural systems regarding energy performance of the envelope of a commercial building located in the bioclimatic zones 1 to 8 in Brazil, using computer simulation. The method used to achieve this goal includes the following steps: (1) definition and configuration of the base case; (2) definition and configuration of the reference model; (3) optimization of energy modeling; (4) energy modeling and comparison of consumption between the base case and the reference model. Main results showed that thermal bridges in reinforced concrete interfere on the building's energy performance and that the impact is related to the WWR (window-to-wall ratio) on the building. For hotel buildings with WWR from 30% to 45%, thermal bridges imply a decrease in estimated consumption, which can reach 10%, depending on the bioclimatic zone. For 60% WWR, the non-consideration of thermal bridges can represent up to 5% of increase in estimated consumption, depending on the Brazilian bioclimatic zone.
文摘Illyria hotel (formerly Bozhur) was built during the sixties in the heart of the actual Kosovo's capital Prishtina, according to former old Yugoslav standards in a Modernist architectural style. It represents a massive structural system with brick walls up to 54 cm thick and "avramenko" type reinforced concrete floors. The investor's aim was to add another two floors on the top of the existing ones and to build two level underground parking floors, a health spa centre, whilst at the vicinity of the existing building (the northern side) to erect a new 17 story-high brand new hotel and administration building. The retrofitting of the structure as well as construction of the new structure has been done in full accordance with the new structural Eurocodes' recommendations. 3D FEM (finite element method) modeling was used for the analysis and design, using ETABS v 9.5 nonlinear and ARSAP 2010 (Autodesk Robot Structural Analysis Professional 2010). Response spectrum design according to EC 8,3.2.2.4 has been used for seismic analysis and design with a reference peak ground acceleration on type A ground Of AgR = 0.25 g.