期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
现代钢筋混凝土高屋结构设计问题与抗震措施
1
作者 凌德明 《今日科苑》 2007年第14期174-175,共2页
随着高层建筑在我国的迅速发展,随着抗震理论的深入发展,抗震措施已成为房屋结构设计时重点观注的问题,毕竟无人可以小窥地震给人们与国民经济带来的危害。尤其是近年来高层建筑的迅速发展,至使建筑高度不断增加,建筑类型与功能也愈来... 随着高层建筑在我国的迅速发展,随着抗震理论的深入发展,抗震措施已成为房屋结构设计时重点观注的问题,毕竟无人可以小窥地震给人们与国民经济带来的危害。尤其是近年来高层建筑的迅速发展,至使建筑高度不断增加,建筑类型与功能也愈来愈复杂,结构体系也更加多样化。由于高层建筑的发展速度过快在结构设计过程中就无法避免的会出现遗漏或错误。因此有必要将设计过程中易出现的问题做一下总结,并针对钢混结构设计中抗震措施的要点及常用的抗震分析方法加以说明,以便同行业人士借鉴与参考。 展开更多
关键词 钢混高层建筑 结构设计问题 抗震措施的要点与常用分析法
下载PDF
Application of Compactness Detection to Complicated Concrete-Filled Steel Tube by Ultrasonic Method 被引量:1
2
作者 杨建江 王飞 +1 位作者 陆苏亮 王川 《Transactions of Tianjin University》 EI CAS 2014年第2期126-132,共7页
An example of using ultrasonic method to detect the compactness of complicated concrete-filled steel tube in certain high-rise building was discussed in this study.Because of the particularity of the complicated concr... An example of using ultrasonic method to detect the compactness of complicated concrete-filled steel tube in certain high-rise building was discussed in this study.Because of the particularity of the complicated concrete-filled steel tubular column,the plane detection method and embedded sounding pipe method were adopted in the process of effectively detecting the column.According to the results of the plane detection method and embedded sounding pipe method,the cementing status of steel tube and concrete can be concluded,which cannot be judged by the hammering method in the rectangular steel tube-reinforced concrete. 展开更多
关键词 ultrasonic method concrete-filled steel tube plane detection method embedded sounding pipe method COMPACTNESS
下载PDF
Elastic-plastic study on high building with SRC transferring story 被引量:1
3
作者 李玉荣 裘涛 孙炳楠 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2006年第3期407-414,共8页
A new type of transferring structure for steel reinforced concrete (SRC) beams is used in high building. The pushover analysis method was used to study the failure mechanism and ductility of SRC transferring structure... A new type of transferring structure for steel reinforced concrete (SRC) beams is used in high building. The pushover analysis method was used to study the failure mechanism and ductility of SRC transferring structure through consulting pseudo-static test results for the structure. And, the occurrence order and position of the plastic hinge, the weak story and seismic capacity of high building with SRC transferring story were also studied through consulting shaking table test results for the high building, showing that the seismic behavior of high building with SRC transferring story is good. 展开更多
关键词 Steel reinforced concrete (SRC) Transferring structure for SRC beams Static pushover analysis High building Pseudo-static test Shaking table test
下载PDF
The Structural Behavior of Low/Medium/High Rise Concrete Office Buildings in Kuwait 被引量:1
4
作者 Tarek A. Awida 《Journal of Civil Engineering and Architecture》 2010年第10期59-65,共7页
The main concern of this paper is to provide an extensive study for the structural behavior of low/medium/high rise office buildings aiming to deepen structure and architect designers understanding for such type of bu... The main concern of this paper is to provide an extensive study for the structural behavior of low/medium/high rise office buildings aiming to deepen structure and architect designers understanding for such type of buildings. The study is performed on reinforced concrete and emphasized only on Kuwait city conditions for wind. Regular layout plan building with different heights ranging from five to fifty typical office stories are investigated in this study. Three dimensional finite element techniques through ETABS software are used in conducting analysis for structures presented here-in. A serviceability study is performed to ensure that buildings have sufficient stability to limit lateral drift and peak acceleration within the acceptable range of occupancy comfort. In addition, an ultimate strength study is carried out to design and verify that all the structural elements are designed to withstand factored gravity and lateral loadings in a safe manner according to the international building codes. The building slenderness ratio and the building core size and location are the studied parameters since they are the key drivers for the efficient structural design. Analysis results are presented and discussed and finally conclusions are summarized as guidelines for designers of concrete office buildings in Kuwait. 展开更多
关键词 Low/medium/high-rise structures office buildings finite element reinforced concrete analysis and design.
下载PDF
上一页 1 下一页 到第