Cave-in failure is apt to occur in joints of trusses made of square hollow sections. In order to turn the failure mode into a strength failure mode of joint members, the idea is proposed that the chord of the truss is...Cave-in failure is apt to occur in joints of trusses made of square hollow sections. In order to turn the failure mode into a strength failure mode of joint members, the idea is proposed that the chord of the truss is grouted to increase the cave-in beating capacity of a hollow tube chord. An experiment of eight specimens of N- joints made of grout-filled square steel tubes is performed. Based on the experimental study, the geometrical parameters of specimens are analyzed, and the effects of the confinement index ε, the spacing between the two web members g and the ratio of side length of the vertical web member to that of the chord β on the behavior of specimens are investigated through simulation analysis by simulation analyses, the mechanical properties and the failure an ANSYS program. Based on the test results and modes of this kind of joints are analyzed and the formulae to predict the ultimate bearing capacities corresponding to different failure modes are developed. The ultimate bearing capacity of compressive N-joints is calculated in accordance with the cave-in failure mode of a chord member; the ultimate bearing capacity of tension N-joints is calculated in accordance with the punchingshear failure mode; the ultimate bearing capacity of a chord member is calculated in accordance with the shear failure mode in normal sections.展开更多
External confinement by fiber reinforced polymer (FRP) is an efficient technique to increase the bearing capacity and ductility of concrete. To better study the mechanical behavior of bidirectional FRP confined concre...External confinement by fiber reinforced polymer (FRP) is an efficient technique to increase the bearing capacity and ductility of concrete. To better study the mechanical behavior of bidirectional FRP confined concrete, the yield criterion of bidirectional FRP is presented based on the static equilibrium condition in this paper, and a model for calculating the bearing capacity of bidirectional FRP confined concrete is established. The model can capture the character of bidirectional FRP confined concrete. Effects of the confinement effect coefficient, the unconfined concrete strength and the material properties of FRP on bearing capacity are analyzed. Results show that each parameter has different effects on the bearing capacity of bidirectional FRP confined concrete.展开更多
基金The National Natural Science Foundation of China(No50178026)Program for New Century Excellent Talents in University+1 种基金the Key Technologies R & D Program of Heilongjiang Province(NoGC04A609)the Key Technologies R & D Program of Harbin City(No2004AA9CS187)
文摘Cave-in failure is apt to occur in joints of trusses made of square hollow sections. In order to turn the failure mode into a strength failure mode of joint members, the idea is proposed that the chord of the truss is grouted to increase the cave-in beating capacity of a hollow tube chord. An experiment of eight specimens of N- joints made of grout-filled square steel tubes is performed. Based on the experimental study, the geometrical parameters of specimens are analyzed, and the effects of the confinement index ε, the spacing between the two web members g and the ratio of side length of the vertical web member to that of the chord β on the behavior of specimens are investigated through simulation analysis by simulation analyses, the mechanical properties and the failure an ANSYS program. Based on the test results and modes of this kind of joints are analyzed and the formulae to predict the ultimate bearing capacities corresponding to different failure modes are developed. The ultimate bearing capacity of compressive N-joints is calculated in accordance with the cave-in failure mode of a chord member; the ultimate bearing capacity of tension N-joints is calculated in accordance with the punchingshear failure mode; the ultimate bearing capacity of a chord member is calculated in accordance with the shear failure mode in normal sections.
基金Sponsored by the National Natural Science Foundation of China(Grant No.50538060)the Excellent Young College Teacher Foundation of Anhui Province(Grant No.2009SQRZ081)
文摘External confinement by fiber reinforced polymer (FRP) is an efficient technique to increase the bearing capacity and ductility of concrete. To better study the mechanical behavior of bidirectional FRP confined concrete, the yield criterion of bidirectional FRP is presented based on the static equilibrium condition in this paper, and a model for calculating the bearing capacity of bidirectional FRP confined concrete is established. The model can capture the character of bidirectional FRP confined concrete. Effects of the confinement effect coefficient, the unconfined concrete strength and the material properties of FRP on bearing capacity are analyzed. Results show that each parameter has different effects on the bearing capacity of bidirectional FRP confined concrete.