Based on blasting demolition of high thin-wall hyperbolic reinforced concrete cool tower, by virtue of engineering practice of blasting the tube concrete structures, the analysis and research were made on the mechanis...Based on blasting demolition of high thin-wall hyperbolic reinforced concrete cool tower, by virtue of engineering practice of blasting the tube concrete structures, the analysis and research were made on the mechanism of cool tower collapse through selecting blasting parameters and selecting gap form, gap size and gap angle. The cool tower was twisted, collapsed directionally and broken well according to the design requirements. The expected results and purposes of blasting were obtained with no back blow, total blasted pile approximates to 4 - 5 m, no occurrence of flying stones and no damage to fixed buildings and equipment, the large-sized hyperbolic thin-wall reinforced concrete cool towers are twisted during blasting and it collapses well with good breaking. The test and measurement of blasting vibrating velocity was carried out during blasting and the measuring results are much less than critical values specified by Safety Regulations for Blasting. The study shows that gap form, gap size and gap angle are the key factors to cool tower collapse and will give beneficial references to related theoretical study and field application.展开更多
A real-size experiment on 11 tubes was done to study the performance o f centrifugal concrete-filled steel tubes under bending and torsion. This pape r first introduces the relevant operating method,equipment,subjects...A real-size experiment on 11 tubes was done to study the performance o f centrifugal concrete-filled steel tubes under bending and torsion. This pape r first introduces the relevant operating method,equipment,subjects and process es. The factors that affect deformation and stiffness and the break mechanism un der different loading were studied. Experimental stress analysis showed that the values of practical critical stress of steel tubes accorded well with the MISES Yielding Rule. The correlative equation (on the bearing capacity of a structura l member under bending and torsion) deduced in this study may provide valuable reference for the design of this structural member.展开更多
An important consideration when using hot-dip galvanized tubular structures is the uncertainty of the joint behaviour due to the possible reduction in the global joint resistance produced by the vent holes required fo...An important consideration when using hot-dip galvanized tubular structures is the uncertainty of the joint behaviour due to the possible reduction in the global joint resistance produced by the vent holes required for the galvanizing process. This paper assesses the effect on the joint strength of the angle between the brace members and the chord in a K- or N-joints made with rectangular hollow sections. The study is focused on the case when those brace members include characteristic holes required for the hot-dip galvanizing process. To accomplish the objective of the proposed work, some tests on full-scale K- and N-joints, including angles of 35°, 45°, 55° and 90°, were carried out. The experimental work was complemented by a validated numerical simulation in order to give some design recommendations and to extend the research to other joint configurations.展开更多
文摘Based on blasting demolition of high thin-wall hyperbolic reinforced concrete cool tower, by virtue of engineering practice of blasting the tube concrete structures, the analysis and research were made on the mechanism of cool tower collapse through selecting blasting parameters and selecting gap form, gap size and gap angle. The cool tower was twisted, collapsed directionally and broken well according to the design requirements. The expected results and purposes of blasting were obtained with no back blow, total blasted pile approximates to 4 - 5 m, no occurrence of flying stones and no damage to fixed buildings and equipment, the large-sized hyperbolic thin-wall reinforced concrete cool towers are twisted during blasting and it collapses well with good breaking. The test and measurement of blasting vibrating velocity was carried out during blasting and the measuring results are much less than critical values specified by Safety Regulations for Blasting. The study shows that gap form, gap size and gap angle are the key factors to cool tower collapse and will give beneficial references to related theoretical study and field application.
文摘A real-size experiment on 11 tubes was done to study the performance o f centrifugal concrete-filled steel tubes under bending and torsion. This pape r first introduces the relevant operating method,equipment,subjects and process es. The factors that affect deformation and stiffness and the break mechanism un der different loading were studied. Experimental stress analysis showed that the values of practical critical stress of steel tubes accorded well with the MISES Yielding Rule. The correlative equation (on the bearing capacity of a structura l member under bending and torsion) deduced in this study may provide valuable reference for the design of this structural member.
文摘An important consideration when using hot-dip galvanized tubular structures is the uncertainty of the joint behaviour due to the possible reduction in the global joint resistance produced by the vent holes required for the galvanizing process. This paper assesses the effect on the joint strength of the angle between the brace members and the chord in a K- or N-joints made with rectangular hollow sections. The study is focused on the case when those brace members include characteristic holes required for the hot-dip galvanizing process. To accomplish the objective of the proposed work, some tests on full-scale K- and N-joints, including angles of 35°, 45°, 55° and 90°, were carried out. The experimental work was complemented by a validated numerical simulation in order to give some design recommendations and to extend the research to other joint configurations.