期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
铜/金修饰电极-阴离子交换色谱-直流安培法测定阿米卡星注射液组分 被引量:2
1
作者 习玲玲 朱岩 《分析化学》 SCIE EI CAS CSCD 北大核心 2008年第5期678-682,共5页
建立了一种用阴离子交换色谱分离、以自制铜/金修饰电极为工作电极的直流安培电化学法(DC)直接检测硫酸阿米卡星注射液中主要组分及杂质含量的分析方法。考察了流动相浓度、测定电位等参数对色谱分离和测定的影响。在固定相为CarboPa... 建立了一种用阴离子交换色谱分离、以自制铜/金修饰电极为工作电极的直流安培电化学法(DC)直接检测硫酸阿米卡星注射液中主要组分及杂质含量的分析方法。考察了流动相浓度、测定电位等参数对色谱分离和测定的影响。在固定相为CarboPacPA10阴离子交换柱、流动相为26mmol/LNaOH的色谱条件下,检测电位为0.64V时,阿米卡星在0.0005-0.02g/L(r=0.9989)和0.02-0.2g/L(r=0.9991)两个浓度范围内呈线性。与裸Au电极在采用脉冲安培检测模式(PAD)时相比,电化学检测所需要的碱性强度低(pH〈13),而且测定灵敏度高,线性范围宽。本方法不需要柱前和柱后衍生化,能同时测定硫酸阿米卡星注射液中的主要组分和杂质组分。修饰电极制作方法简单,催化稳定性好,可望被应用到流动注射、毛细管电泳等其它流动体系中,对硫酸阿米卡星原料药、注射液等实际样品中的各组分进行测定。 展开更多
关键词 铜/金修饰电极 阴离子交换色谱 直流安培法 阿米卡星
下载PDF
Electrocatalytic behaviour of Ni and NiCu alloy modified glassy carbon electrode in electro-oxidation of contraflam 被引量:1
2
作者 Naeemy Ali Mohammadi Ali +1 位作者 Ehsani Ali Aghassi Ali 《Journal of Central South University》 SCIE EI CAS CSCD 2017年第8期1703-1712,共10页
The electrocatalytic oxidation of contraflam was investigated in alkaline solution on nickel and nickel–copper alloy modified glassy carbon electrodes(GC/Ni and GC/NiCu). We prepared these electrodes by galvanostatic... The electrocatalytic oxidation of contraflam was investigated in alkaline solution on nickel and nickel–copper alloy modified glassy carbon electrodes(GC/Ni and GC/NiCu). We prepared these electrodes by galvanostatic deposition and the surface morphologies and compositions of electrodes were determined by energy-dispersive X-ray(EDX) and scanning electron microscopy(SEM). Cyclic voltammetry and chronoamperometric methods were employed to characterize the oxidation process and its kinetics. Voltammetric studies exhibit one pair of well-defined redox peaks, which is ascribed to the redox process of the nickel and followed by the greatly enhanced current response of the anodic peak in the presence of contraflam and a decrease in the corresponding cathodic current peak. This indicates that the immobilized redox mediator on the electrode surface was oxidized contraflam via an electrocatalytic mechanism. The catalytic currents increased linearly with the concentration of contraflam in the range of 0.25– 1.5 mmol/L. The anodic peak currents were linearly proportional to the square root of scan rate. This behaviour is the characteristic of a diffusion-controlled process. The determination of contraflam in capsules is applied satisfactorily by modified electrode. 展开更多
关键词 galvanostatic deposition nickel nickel-copper alloy contraflam modified electrodes cyclic voltammetry oxidation
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部