Abstract We study dynamics in two mutually coupling multi-quantum-well lasers. We carry out theoretical and numerical analysis of synchronization, anti-synchronization, in-phase locking in the two identical lasers but...Abstract We study dynamics in two mutually coupling multi-quantum-well lasers. We carry out theoretical and numerical analysis of synchronization, anti-synchronization, in-phase locking in the two identical lasers but detuning, in detain. It is proved that the coupling level determines stability of the lasers by analyzing the eigenvalue equation. Critical case of locking is discussed via the phase difference equation. Quasi-period and stable states in the two lasers are investigated via varying the current, detuning and coupling level.展开更多
A comprehensive simulation was performed to better understand the impacts and effects of the additional technical noises on weak-light phase-locking for LISA. The result showed that the phase of the slave laser tracke...A comprehensive simulation was performed to better understand the impacts and effects of the additional technical noises on weak-light phase-locking for LISA. The result showed that the phase of the slave laser tracked well with the received transmitting light under different noise level, and the locking precision was limited by the phase readout noise when the laser frequency noise and clock jitter noise were removed. This result was then confirmed by a benchtop experimental test. The required LISA noise floor was recovered from the simulation which proved the validity of the simulation program. In order to convert the noise function into real time data with random characteristics, an algorism based on Fourier transform was also invented.展开更多
Objective: Studies showed elastic stable intramedullary nailing (ESIN) of displaced midclavicular fractures has excellent outcomes, as well as high complication rates and specific problems. The aim was to discuss E...Objective: Studies showed elastic stable intramedullary nailing (ESIN) of displaced midclavicular fractures has excellent outcomes, as well as high complication rates and specific problems. The aim was to discuss ESIN of midshaft clavicular fractures.Methods: Totally 60 eligible patients (aged 18-63 years) were randomized to either ESIN group or non-operative group between January 2007 and May 2008. Clavicular shortening was measured after trauma and osseous consolidation.Radiographic union and complications were assessed. Function analysis including Constant shoulder scores and disabilities of the arm, shoulder and hand (DASH) scores were performed after a 15-month follow-up.Results: ESIN led to a signifcantly shorter time to union, especially for simple fractures. In ESIN group, all patients got fracture union, of which 5 cases had medial skin irritation and 1 patient needed revision surgery because of implant failure. In the nonoperative group, there were 3 nonunion cases and 2 symptomatic malunions developed requiring corrective osteotomy. At 15 months after intramedullary stabilization, patients in the ESIN group were more satisfied with the appearance of the shoulder and overall outcome, and they benefited a lot from the great improvement of post-traumatic clavicular shortening. Furthermore,DASH scores were lower and Constant scores were significantly higher in contrast to the non-operative group.Conclusion: ESIN is a safe minimally invasive surgical technique with lower complication rate, faster return to daily activities, excellent cosmetic and better functional results,restoration of clavicular length for treating mid-shaft clavicular fractures, resulting in high overall satisfaction, which can be regard as an alternative to plate fixation or nonoperative treatment of mid-shaft clavicular fractures.展开更多
文摘Abstract We study dynamics in two mutually coupling multi-quantum-well lasers. We carry out theoretical and numerical analysis of synchronization, anti-synchronization, in-phase locking in the two identical lasers but detuning, in detain. It is proved that the coupling level determines stability of the lasers by analyzing the eigenvalue equation. Critical case of locking is discussed via the phase difference equation. Quasi-period and stable states in the two lasers are investigated via varying the current, detuning and coupling level.
基金supported by the Space Science Research Projects in Advance(Grant No.O930143XM1)the Scientific Equipment Development and Research Project(Grant No.Y231411YB1) of Chinese Academy of Sciences
文摘A comprehensive simulation was performed to better understand the impacts and effects of the additional technical noises on weak-light phase-locking for LISA. The result showed that the phase of the slave laser tracked well with the received transmitting light under different noise level, and the locking precision was limited by the phase readout noise when the laser frequency noise and clock jitter noise were removed. This result was then confirmed by a benchtop experimental test. The required LISA noise floor was recovered from the simulation which proved the validity of the simulation program. In order to convert the noise function into real time data with random characteristics, an algorism based on Fourier transform was also invented.
文摘Objective: Studies showed elastic stable intramedullary nailing (ESIN) of displaced midclavicular fractures has excellent outcomes, as well as high complication rates and specific problems. The aim was to discuss ESIN of midshaft clavicular fractures.Methods: Totally 60 eligible patients (aged 18-63 years) were randomized to either ESIN group or non-operative group between January 2007 and May 2008. Clavicular shortening was measured after trauma and osseous consolidation.Radiographic union and complications were assessed. Function analysis including Constant shoulder scores and disabilities of the arm, shoulder and hand (DASH) scores were performed after a 15-month follow-up.Results: ESIN led to a signifcantly shorter time to union, especially for simple fractures. In ESIN group, all patients got fracture union, of which 5 cases had medial skin irritation and 1 patient needed revision surgery because of implant failure. In the nonoperative group, there were 3 nonunion cases and 2 symptomatic malunions developed requiring corrective osteotomy. At 15 months after intramedullary stabilization, patients in the ESIN group were more satisfied with the appearance of the shoulder and overall outcome, and they benefited a lot from the great improvement of post-traumatic clavicular shortening. Furthermore,DASH scores were lower and Constant scores were significantly higher in contrast to the non-operative group.Conclusion: ESIN is a safe minimally invasive surgical technique with lower complication rate, faster return to daily activities, excellent cosmetic and better functional results,restoration of clavicular length for treating mid-shaft clavicular fractures, resulting in high overall satisfaction, which can be regard as an alternative to plate fixation or nonoperative treatment of mid-shaft clavicular fractures.