A 2.5Gb/s/ch data recovery (DR) circuit is designed for an SFI-5 interface. To make the parallel data bit-synchronization and reduce the bit error rate (BER) ,a delay locked loop (DLL) is used to place the cente...A 2.5Gb/s/ch data recovery (DR) circuit is designed for an SFI-5 interface. To make the parallel data bit-synchronization and reduce the bit error rate (BER) ,a delay locked loop (DLL) is used to place the center of the data eye exactly at the rising edge of the data-sampling clock. A single channel DR circuit was fabricated in TSMC's standard 0. 18μm CMOS process. The chip area is 0. 46mm^2. With a 2^32 - 1 pseudorandom bit sequence (PRBS) input,the RMS jitter of the recovered 2.5Gb/s data is 3.3ps. The sensitivity of the single channel DR is less than 20mV with 10-12 BER.展开更多
Abstract We study dynamics in two mutually coupling multi-quantum-well lasers. We carry out theoretical and numerical analysis of synchronization, anti-synchronization, in-phase locking in the two identical lasers but...Abstract We study dynamics in two mutually coupling multi-quantum-well lasers. We carry out theoretical and numerical analysis of synchronization, anti-synchronization, in-phase locking in the two identical lasers but detuning, in detain. It is proved that the coupling level determines stability of the lasers by analyzing the eigenvalue equation. Critical case of locking is discussed via the phase difference equation. Quasi-period and stable states in the two lasers are investigated via varying the current, detuning and coupling level.展开更多
Oscillator IC technique is developed by combining injecting synchronization technique with a ring VCO.Using the technique,a novel 2 488GHz of monolithical integrated injected synchronized ring VCO (ISRVCO) is realize...Oscillator IC technique is developed by combining injecting synchronization technique with a ring VCO.Using the technique,a novel 2 488GHz of monolithical integrated injected synchronized ring VCO (ISRVCO) is realized in a standard 0 25μm CMOS process.The ISRVCO is characterized by the following performances: -100dBc /Hz@1MHz at free running frequency,-91 7dBc/Hz@10kHz when injection is locked.With the 3 3V of power supply,the tuning range is 150MHz and the locking range is 100MHz with 50m V p p signal injection.展开更多
Measure synchronization in coupled Hamiltonian systems is a novel synchronization phenomenon. The measure synchronization on symplectic map is observed numerically, for identical coupled systems with different paramet...Measure synchronization in coupled Hamiltonian systems is a novel synchronization phenomenon. The measure synchronization on symplectic map is observed numerically, for identical coupled systems with different parameters. We have found the properties of the characteristic frequency and the amplitude of phase locking in regular motion when the measure synchronization of coupled systems is obtained. The relations between the change of the largest Lyapunov exponent and the course of phase desynchronization are also discussed in coupled systems, some useful results are obtained. A new approach is proposed for describing the measure synchronization of coupled systems numerically,which is advantage in judging the measure synchronization, especially for the coupled systems in nonregular region.展开更多
Synchronous sampling is very essential in underwater multilinear array seismic exploration system in which every acquisition node(AN)samples analog signals by its own analog-digital converter(ADC).Aiming at the proble...Synchronous sampling is very essential in underwater multilinear array seismic exploration system in which every acquisition node(AN)samples analog signals by its own analog-digital converter(ADC).Aiming at the problems of complex synchronous sampling method and long locking time after varying sampling rate in traditional underwater seismic exploration system,an improved synchronous sampling model based on the master-slave synchronous model and local clock asynchronous drive with non phase locked loop(PLL)is built,and a high-precision synchronous sampling method is proposed,which combines the short-term stability of local asynchronous driving clock with the master-slave synchronous calibration of local sampling clock.Based on the improved synchronous sampling model,the influence of clock stability,transmission delay and phase jitter on synchronous sampling error is analyzed,and a high-precision calibration method of synchronous sampling error based on step-by-step compensation of transmission delay is proposed.The model and method effectively realize the immunity of phase jitter on synchronous sampling error in principle,and compensate the influence of signal transmission delay on synchronous sampling error.At the same time,it greatly reduces the complexity of software and hardware implementation of synchronous sampling,and solves the problem of long locking time after changing the sampling rate in traditional methods.The experimental system of synchronous sampling for dual linear array is built,and the synchronous sampling accuracy is better than 5 ns.展开更多
文摘A 2.5Gb/s/ch data recovery (DR) circuit is designed for an SFI-5 interface. To make the parallel data bit-synchronization and reduce the bit error rate (BER) ,a delay locked loop (DLL) is used to place the center of the data eye exactly at the rising edge of the data-sampling clock. A single channel DR circuit was fabricated in TSMC's standard 0. 18μm CMOS process. The chip area is 0. 46mm^2. With a 2^32 - 1 pseudorandom bit sequence (PRBS) input,the RMS jitter of the recovered 2.5Gb/s data is 3.3ps. The sensitivity of the single channel DR is less than 20mV with 10-12 BER.
文摘Abstract We study dynamics in two mutually coupling multi-quantum-well lasers. We carry out theoretical and numerical analysis of synchronization, anti-synchronization, in-phase locking in the two identical lasers but detuning, in detain. It is proved that the coupling level determines stability of the lasers by analyzing the eigenvalue equation. Critical case of locking is discussed via the phase difference equation. Quasi-period and stable states in the two lasers are investigated via varying the current, detuning and coupling level.
文摘Oscillator IC technique is developed by combining injecting synchronization technique with a ring VCO.Using the technique,a novel 2 488GHz of monolithical integrated injected synchronized ring VCO (ISRVCO) is realized in a standard 0 25μm CMOS process.The ISRVCO is characterized by the following performances: -100dBc /Hz@1MHz at free running frequency,-91 7dBc/Hz@10kHz when injection is locked.With the 3 3V of power supply,the tuning range is 150MHz and the locking range is 100MHz with 50m V p p signal injection.
基金国家重点基础研究发展计划(973计划),国家自然科学基金,the Innovation Funds for Laser Technology
文摘Measure synchronization in coupled Hamiltonian systems is a novel synchronization phenomenon. The measure synchronization on symplectic map is observed numerically, for identical coupled systems with different parameters. We have found the properties of the characteristic frequency and the amplitude of phase locking in regular motion when the measure synchronization of coupled systems is obtained. The relations between the change of the largest Lyapunov exponent and the course of phase desynchronization are also discussed in coupled systems, some useful results are obtained. A new approach is proposed for describing the measure synchronization of coupled systems numerically,which is advantage in judging the measure synchronization, especially for the coupled systems in nonregular region.
基金National Key Research and Development Program of China(No.2018YFE0208200)National Natural Science Foundation of China(Nos.61971307,61905175,51775377)+5 种基金National Key Research and Development Plan Project(No.2020YFB2010800)The Fok Ying Tung Education Foundation(No.171055)China Postdoctoral Science Foundation(No.2020M680878)Guangdong Province Key Research and Development Plan Project(No.2020B0404030001)Tianjin Science and Technology Plan Project(No.20YDTPJC01660)Project of Foreign Affairs Committee of China Aviation Development Sichuan Gas Turbine Research Institute(Nos.GJCZ-2020-0040,GJCZ-2020-0041)。
文摘Synchronous sampling is very essential in underwater multilinear array seismic exploration system in which every acquisition node(AN)samples analog signals by its own analog-digital converter(ADC).Aiming at the problems of complex synchronous sampling method and long locking time after varying sampling rate in traditional underwater seismic exploration system,an improved synchronous sampling model based on the master-slave synchronous model and local clock asynchronous drive with non phase locked loop(PLL)is built,and a high-precision synchronous sampling method is proposed,which combines the short-term stability of local asynchronous driving clock with the master-slave synchronous calibration of local sampling clock.Based on the improved synchronous sampling model,the influence of clock stability,transmission delay and phase jitter on synchronous sampling error is analyzed,and a high-precision calibration method of synchronous sampling error based on step-by-step compensation of transmission delay is proposed.The model and method effectively realize the immunity of phase jitter on synchronous sampling error in principle,and compensate the influence of signal transmission delay on synchronous sampling error.At the same time,it greatly reduces the complexity of software and hardware implementation of synchronous sampling,and solves the problem of long locking time after changing the sampling rate in traditional methods.The experimental system of synchronous sampling for dual linear array is built,and the synchronous sampling accuracy is better than 5 ns.