Corrosion behavior of TP316L was investigated with simulated atmosphere and ash deposition for the superheater in biomass boiler.Corrosion dynamic curves were plotted by mass gain.The results showed that the corrosion...Corrosion behavior of TP316L was investigated with simulated atmosphere and ash deposition for the superheater in biomass boiler.Corrosion dynamic curves were plotted by mass gain.The results showed that the corrosion was dependent on temperature and was greatly accelerated by ash deposition.The mass gain was distinctly reduced in the presence of SO2 with and without ash deposition on the specimens.Corrosion rates with ash deposit at different temperatures were calculated.Two feasible methods were provided to avoid serious high-temperature corrosion in the biomass boiler.展开更多
Reburning was applied to Polish automatic coal-fired retort boiler (25 kW).The use of bio-syngas reduced NOx emissions from the boiler by over 25%,below the significant level of 200 mg/m3 .Reburning was carried out us...Reburning was applied to Polish automatic coal-fired retort boiler (25 kW).The use of bio-syngas reduced NOx emissions from the boiler by over 25%,below the significant level of 200 mg/m3 .Reburning was carried out using an integrated system consisting of the boiler and a fixed-bed 60 kW (GazEla) gasification reactor.The process gas was continuously introduced above the coal burner of the boiler.The process parameters of the boiler and the gasifier were also measured and compared with the other units.Characteristic NOx emissions from automatic and manually operated boilers were also presented.展开更多
A district heating and hot water supply system is presented which synthetically utilizes geothermal energy,solar thermal energy and natural gas thermal energy.The multi-energy utilization system has been set at the ne...A district heating and hot water supply system is presented which synthetically utilizes geothermal energy,solar thermal energy and natural gas thermal energy.The multi-energy utilization system has been set at the new campus of Tianjin Polytechnic University(TPU),A couple of deep geothermal wells which are 2 300 m in depth were dug,Deep geothermal energy cascade utilization is achieved by two stages of plate heat exchangers(PHE) and two stages of water source heat pumps(WSHP).Shallow geothermal energy is used in assistant heating by two ground coupled heat pumps(GCHPs) with 580 vertical ground wells which are 120 m in depth.Solar thermal energy collected by vacuum tube arrays(VTAs) and geothermal energy are complementarily utilized to make domestic hot water.Superfluous solar energy can be stored in shallow soil for the GCHP utilization.The system can use fossil fuel thermal energy by two natural gas boilers(NGB) to assist in heating and making hot water.The heating energy efficiency was measured in the winter of 2010-2011.The coefficients of performance(COP) under different heating conditions are discussed.The performance of hot water production is tested in a local typical winter day and the solar thermal energy utilization factor is presented.The rusults show that the average system COP is 5.75 or 4.96 under different working conditions,and the typical solar energy utilization factor is 0.324.展开更多
The paper describes numerical and experimental study on reduction of NOx emissions in a 600 MW tangentially fired boiler furnace under different operating conditions. A simplified NOX formation mechanism model, along ...The paper describes numerical and experimental study on reduction of NOx emissions in a 600 MW tangentially fired boiler furnace under different operating conditions. A simplified NOX formation mechanism model, along with the gas-particle multiphase flow model, is adopted. The prediction yields encouraging results as compared to experimental data.展开更多
The main technologies for reducing flue gas heat loss of pulverized coal-fired boilers are introduced, and the suitability of these technologies for boiler operation and the principles for selection of these technolog...The main technologies for reducing flue gas heat loss of pulverized coal-fired boilers are introduced, and the suitability of these technologies for boiler operation and the principles for selection of these technologies are explored. The main conclusions are: 1) the non-equilibrium control over flue gas flow rates at the inlet of the air heater and the reversal rotation of the air heater rotator should be popularized as regular technologies in large boilers; 2) increasing the area of the air heater to reduce the flue gas heat loss in pulverized coal-fired boilers should be the top option and increasing the area of the economizer be the next choice; 3) low- pressure economizer technology could save energy under special conditions and should be compared with the technology of increasing economizer area in terms of technical economics when the latter is feasible; 4) the hot primary air heater is only suitable to the pnlvefizing system with a large amount of cold air mixed.展开更多
Numerical simulation is applied to gas-particle flows of the primary and the secondary air ducts and burner region, and of two kinds of swirl burners. The modeling results of Radial Bias Combustion (RBC) burner well a...Numerical simulation is applied to gas-particle flows of the primary and the secondary air ducts and burner region, and of two kinds of swirl burners. The modeling results of Radial Bias Combustion (RBC) burner well agreed with the data from the three-dimensional Phase-Doppler anemometry (PDA) experiment by Li, et al. The modeling test conducted in a 1025 t/h boiler was to study the quality of aerodynamics for a Central Fuel Rich (CFR) burner, and the Internal Recirculation Zone (IRZ) was measured. In addition, gas-particle flows with a CFR burner were investigated by numerical simulation, whose results accorded with the test data fundamentally. By analyzing the distribution of gas velocity and trajectories of particles respectively, it is found that the primary air’s rigidity of CFR burner is stronger than that of RBC burner, and the primary air mixes with the secondary air later. Furthermore, high concentration region of pulverized coal exists in the burner’s central zone whose atmosphere is reduced, and trajectories of particles in IRZ of CFR burner are longer than that of RBC burner. They are favorable to coal’s ignition and the reduction of NOx emission.展开更多
Classification of energy efficiency system for agricultural heater was discussed and analyzed in order to derive an energy efficiency classification scheme for agricultural heater. Current practices of energy efficien...Classification of energy efficiency system for agricultural heater was discussed and analyzed in order to derive an energy efficiency classification scheme for agricultural heater. Current practices of energy efficiency programs for other products such as residential gas boiler were investigated and analyzed. Test items including energy efficiency and standby power for agricultural heater were analyzed. With the data of residential gas boiler, grade distribution of energy efficiency system was made and evaluated. An energy efficiency classification scheme for agricultural heater was proposed and applied to agricultural heaters, and the scheme was justified. Introducing a new energy efficiency classification system to the agricultural heater industry, it is expected that considerable amount of fossil fuels can be reduced by adopting energy efficiency classification system.展开更多
Candidate materials for water wall of supercritical and ultra-supercritical utility boilers,T23 and T24,were chosen as the experimental samples and exposed to oxidizing atmosphere,reducing atmosphere and oxidizing/red...Candidate materials for water wall of supercritical and ultra-supercritical utility boilers,T23 and T24,were chosen as the experimental samples and exposed to oxidizing atmosphere,reducing atmosphere and oxidizing/reducing alternating atmosphere separately.The corrosion temperature was 450-550?C.The effects of oxygen con-tent and temperature on the corrosion in reducing atmosphere and alternating atmosphere were investigated.The scanning electron microscope(SEM) and energy dispersive spectrometer(EDS) were used to examine the corroded samples.The results show that the corrosion kinetics of T23 and T24 can be described by the double logarithmic equation and parabolic equation respectively.To describe the corrosion of materials accurately it is not sufficient to analyze the macro-mass gain and the macro-thickness of the corroded layer only,but the EDS should be applied to examine the migration depth of corrosive elements O and S.It is revealed that the corrosion becomes more severe when H2S is present in the corrosive gas.S is more active than O,and Cr can reduce the migration of oxygen but not S.The combination corrosion of S and O and pure [S] has a stronger corrodibility than pure H2S.T24 suffers the most severe corrosion at oxygen content of 0.8%.Corrosion is aggravated when the corrosion temperature is above 450 ℃ in the alternating atmosphere.T23 has better corrosion resistance than T24 and W contributes a lot to the corrosion resistance of T23.展开更多
The reasons of introducing cold air into pulverizer are analyzed for boilers with large capacity and high parameters. The temperature rises of the exhaust gas are calculated when varying the amount of the cold air. Th...The reasons of introducing cold air into pulverizer are analyzed for boilers with large capacity and high parameters. The temperature rises of the exhaust gas are calculated when varying the amount of the cold air. The hot primary air heater, a new technology, is developed to eliminate the cold air from the pulverized coal system. The applications, advantages and disadvantages are introduced in detail for the new device and system. It is concluded that introducing cold air into pulverizer is one of the major factors that causes the exhaust gas temperature of boilers with large capacity to be high. The amount of the cold air could be reduced signif icantly, even to zero in some cases by adopting the hot primary air heater, which drops the exhaust gas temperature of the boiler effectively. The hot primary air heater, which could play part roles of the steam-air heater or the hot air recirculation system, could also be used to adjust the exhaust gas temperature within the range of 20 ℃ by controlling the flow rate of the cooling medium. Moreover, the startup period of the steam-air heater or the hot air recirculation system will be shortened, which is a unique advantage of the hot primary air heater among the measures to drop the exhaust gas temperature.展开更多
A work on soot emission control simulation in stoker-fired boiler by secondary air has been done. Some models such as k-e, combustion, radiation, and soot Khan-Greeves have been adopted. Soot production and emission h...A work on soot emission control simulation in stoker-fired boiler by secondary air has been done. Some models such as k-e, combustion, radiation, and soot Khan-Greeves have been adopted. Soot production and emission has been reduced by secondary air; the highest mass concentration is reduced from 7.46 × 10^-14 to 6.94 × 10^15; mass concentration of soot is decreased from 1.12 ×10^-15 to 9.25 ×10^-32 in the upper areas.展开更多
Preliminary investigation shows that air sourced type heat pumps by energy efficiency are competitive with gas boilers having 93% of coefficient of performance (COP) if heat pumps are used in climatic zones, having ...Preliminary investigation shows that air sourced type heat pumps by energy efficiency are competitive with gas boilers having 93% of coefficient of performance (COP) if heat pumps are used in climatic zones, having outside air temperature higher than (-3 ℃ to -5 ℃). But, in such conditions the heat pump's evaporator is covered by ice crust, which cuts off the flow of outside air-heat source through the evaporator of heat pump. For avoiding stating problems it is recommended to use as heat source a mixture of waste warm gases. In this article a high efficiency heating-cooling system is developed, consisting of warm gases mixture sourced heat pump, heating boiler operating simultaneously with heat pump and solar air heater. The heating demand of the served house is shared between boiler and heat pump. Instead of outside air the warm gases mixture enters into evaporator of heat pump. A new construction of heat exchanger was developed. The article presents the structure and principle of operation, as well as the method for optimization and design of suggested system. Analysis proved high energy efficiency and cost effectiveness of the new system.展开更多
文摘Corrosion behavior of TP316L was investigated with simulated atmosphere and ash deposition for the superheater in biomass boiler.Corrosion dynamic curves were plotted by mass gain.The results showed that the corrosion was dependent on temperature and was greatly accelerated by ash deposition.The mass gain was distinctly reduced in the presence of SO2 with and without ash deposition on the specimens.Corrosion rates with ash deposit at different temperatures were calculated.Two feasible methods were provided to avoid serious high-temperature corrosion in the biomass boiler.
基金Projects(DEC-2011/01/B/ST8/07394,DEC-2011/01/D/ST8/07399)supported by the Polish National Centre for Science(NCN)
文摘Reburning was applied to Polish automatic coal-fired retort boiler (25 kW).The use of bio-syngas reduced NOx emissions from the boiler by over 25%,below the significant level of 200 mg/m3 .Reburning was carried out using an integrated system consisting of the boiler and a fixed-bed 60 kW (GazEla) gasification reactor.The process gas was continuously introduced above the coal burner of the boiler.The process parameters of the boiler and the gasifier were also measured and compared with the other units.Characteristic NOx emissions from automatic and manually operated boilers were also presented.
基金Project(2010DFA72740-06) supported by International Science & Technology Cooperation Program of China
文摘A district heating and hot water supply system is presented which synthetically utilizes geothermal energy,solar thermal energy and natural gas thermal energy.The multi-energy utilization system has been set at the new campus of Tianjin Polytechnic University(TPU),A couple of deep geothermal wells which are 2 300 m in depth were dug,Deep geothermal energy cascade utilization is achieved by two stages of plate heat exchangers(PHE) and two stages of water source heat pumps(WSHP).Shallow geothermal energy is used in assistant heating by two ground coupled heat pumps(GCHPs) with 580 vertical ground wells which are 120 m in depth.Solar thermal energy collected by vacuum tube arrays(VTAs) and geothermal energy are complementarily utilized to make domestic hot water.Superfluous solar energy can be stored in shallow soil for the GCHP utilization.The system can use fossil fuel thermal energy by two natural gas boilers(NGB) to assist in heating and making hot water.The heating energy efficiency was measured in the winter of 2010-2011.The coefficients of performance(COP) under different heating conditions are discussed.The performance of hot water production is tested in a local typical winter day and the solar thermal energy utilization factor is presented.The rusults show that the average system COP is 5.75 or 4.96 under different working conditions,and the typical solar energy utilization factor is 0.324.
基金Supported by the National Science Foundation of Zhejiang Province.
文摘The paper describes numerical and experimental study on reduction of NOx emissions in a 600 MW tangentially fired boiler furnace under different operating conditions. A simplified NOX formation mechanism model, along with the gas-particle multiphase flow model, is adopted. The prediction yields encouraging results as compared to experimental data.
文摘The main technologies for reducing flue gas heat loss of pulverized coal-fired boilers are introduced, and the suitability of these technologies for boiler operation and the principles for selection of these technologies are explored. The main conclusions are: 1) the non-equilibrium control over flue gas flow rates at the inlet of the air heater and the reversal rotation of the air heater rotator should be popularized as regular technologies in large boilers; 2) increasing the area of the air heater to reduce the flue gas heat loss in pulverized coal-fired boilers should be the top option and increasing the area of the economizer be the next choice; 3) low- pressure economizer technology could save energy under special conditions and should be compared with the technology of increasing economizer area in terms of technical economics when the latter is feasible; 4) the hot primary air heater is only suitable to the pnlvefizing system with a large amount of cold air mixed.
基金Sponsored by the Ministry of Education of China via the 2004 Year New Century Excellent Talents in University (Grant No NCET-04-0328)Hei-longjiang Province via 2005 Year Key Projects (Grant No GC05A314)
文摘Numerical simulation is applied to gas-particle flows of the primary and the secondary air ducts and burner region, and of two kinds of swirl burners. The modeling results of Radial Bias Combustion (RBC) burner well agreed with the data from the three-dimensional Phase-Doppler anemometry (PDA) experiment by Li, et al. The modeling test conducted in a 1025 t/h boiler was to study the quality of aerodynamics for a Central Fuel Rich (CFR) burner, and the Internal Recirculation Zone (IRZ) was measured. In addition, gas-particle flows with a CFR burner were investigated by numerical simulation, whose results accorded with the test data fundamentally. By analyzing the distribution of gas velocity and trajectories of particles respectively, it is found that the primary air’s rigidity of CFR burner is stronger than that of RBC burner, and the primary air mixes with the secondary air later. Furthermore, high concentration region of pulverized coal exists in the burner’s central zone whose atmosphere is reduced, and trajectories of particles in IRZ of CFR burner are longer than that of RBC burner. They are favorable to coal’s ignition and the reduction of NOx emission.
文摘Classification of energy efficiency system for agricultural heater was discussed and analyzed in order to derive an energy efficiency classification scheme for agricultural heater. Current practices of energy efficiency programs for other products such as residential gas boiler were investigated and analyzed. Test items including energy efficiency and standby power for agricultural heater were analyzed. With the data of residential gas boiler, grade distribution of energy efficiency system was made and evaluated. An energy efficiency classification scheme for agricultural heater was proposed and applied to agricultural heaters, and the scheme was justified. Introducing a new energy efficiency classification system to the agricultural heater industry, it is expected that considerable amount of fossil fuels can be reduced by adopting energy efficiency classification system.
基金Supported by the "Twelfth Five-Year" National Science and Technology Support Program (2011BAK06B04)
文摘Candidate materials for water wall of supercritical and ultra-supercritical utility boilers,T23 and T24,were chosen as the experimental samples and exposed to oxidizing atmosphere,reducing atmosphere and oxidizing/reducing alternating atmosphere separately.The corrosion temperature was 450-550?C.The effects of oxygen con-tent and temperature on the corrosion in reducing atmosphere and alternating atmosphere were investigated.The scanning electron microscope(SEM) and energy dispersive spectrometer(EDS) were used to examine the corroded samples.The results show that the corrosion kinetics of T23 and T24 can be described by the double logarithmic equation and parabolic equation respectively.To describe the corrosion of materials accurately it is not sufficient to analyze the macro-mass gain and the macro-thickness of the corroded layer only,but the EDS should be applied to examine the migration depth of corrosive elements O and S.It is revealed that the corrosion becomes more severe when H2S is present in the corrosive gas.S is more active than O,and Cr can reduce the migration of oxygen but not S.The combination corrosion of S and O and pure [S] has a stronger corrodibility than pure H2S.T24 suffers the most severe corrosion at oxygen content of 0.8%.Corrosion is aggravated when the corrosion temperature is above 450 ℃ in the alternating atmosphere.T23 has better corrosion resistance than T24 and W contributes a lot to the corrosion resistance of T23.
文摘The reasons of introducing cold air into pulverizer are analyzed for boilers with large capacity and high parameters. The temperature rises of the exhaust gas are calculated when varying the amount of the cold air. The hot primary air heater, a new technology, is developed to eliminate the cold air from the pulverized coal system. The applications, advantages and disadvantages are introduced in detail for the new device and system. It is concluded that introducing cold air into pulverizer is one of the major factors that causes the exhaust gas temperature of boilers with large capacity to be high. The amount of the cold air could be reduced signif icantly, even to zero in some cases by adopting the hot primary air heater, which drops the exhaust gas temperature of the boiler effectively. The hot primary air heater, which could play part roles of the steam-air heater or the hot air recirculation system, could also be used to adjust the exhaust gas temperature within the range of 20 ℃ by controlling the flow rate of the cooling medium. Moreover, the startup period of the steam-air heater or the hot air recirculation system will be shortened, which is a unique advantage of the hot primary air heater among the measures to drop the exhaust gas temperature.
文摘A work on soot emission control simulation in stoker-fired boiler by secondary air has been done. Some models such as k-e, combustion, radiation, and soot Khan-Greeves have been adopted. Soot production and emission has been reduced by secondary air; the highest mass concentration is reduced from 7.46 × 10^-14 to 6.94 × 10^15; mass concentration of soot is decreased from 1.12 ×10^-15 to 9.25 ×10^-32 in the upper areas.
文摘Preliminary investigation shows that air sourced type heat pumps by energy efficiency are competitive with gas boilers having 93% of coefficient of performance (COP) if heat pumps are used in climatic zones, having outside air temperature higher than (-3 ℃ to -5 ℃). But, in such conditions the heat pump's evaporator is covered by ice crust, which cuts off the flow of outside air-heat source through the evaporator of heat pump. For avoiding stating problems it is recommended to use as heat source a mixture of waste warm gases. In this article a high efficiency heating-cooling system is developed, consisting of warm gases mixture sourced heat pump, heating boiler operating simultaneously with heat pump and solar air heater. The heating demand of the served house is shared between boiler and heat pump. Instead of outside air the warm gases mixture enters into evaporator of heat pump. A new construction of heat exchanger was developed. The article presents the structure and principle of operation, as well as the method for optimization and design of suggested system. Analysis proved high energy efficiency and cost effectiveness of the new system.