Rock bolting has firmly used as the coal mine roof reinforcement in underground coal mine. The bolting effect of fully grouted rebar bolt is closely related to the bolt surface profile. This paper provides an experime...Rock bolting has firmly used as the coal mine roof reinforcement in underground coal mine. The bolting effect of fully grouted rebar bolt is closely related to the bolt surface profile. This paper provides an experimental study to confirm that bolt rib internal length has great influence on bolting effect. Pull-out tests were conducted using rebar bolt with different rib spacings of 12, 24, 36 and 48 mm representatively from steel tube and from concrete. Results show that peak load increases 25.3% for bolt with large rib spacing. For pull out using concrete block, the increment of peak load between large and small rib spacing is not significant, but the bolt with large rib spacing has great absorption of deformational energy than small rib spacing bolt. This study provides experimental evidence towards optimum design of rock bolt for understand coal mining industry.展开更多
with the constant popularity of the precast assembly gasification, the application of the composite section beam which can change into different sections is wilder. This passage, based on the hypothesis that the inter...with the constant popularity of the precast assembly gasification, the application of the composite section beam which can change into different sections is wilder. This passage, based on the hypothesis that the interface is smooth, simplify the double composite section beam and deduce the anchorage-bolt-shear and composite-section-beam-bending-capacity formulas when there is a slip on the interface in elastic stage. Moreover, it contains some prospect and summarizes of the later research.展开更多
基金Financial supports for this work,provided by the Open Projects of Research Center of Coal Resources Safe Mining and Clean Utilization,Liaoning of China (No.LNTU15KF02)
文摘Rock bolting has firmly used as the coal mine roof reinforcement in underground coal mine. The bolting effect of fully grouted rebar bolt is closely related to the bolt surface profile. This paper provides an experimental study to confirm that bolt rib internal length has great influence on bolting effect. Pull-out tests were conducted using rebar bolt with different rib spacings of 12, 24, 36 and 48 mm representatively from steel tube and from concrete. Results show that peak load increases 25.3% for bolt with large rib spacing. For pull out using concrete block, the increment of peak load between large and small rib spacing is not significant, but the bolt with large rib spacing has great absorption of deformational energy than small rib spacing bolt. This study provides experimental evidence towards optimum design of rock bolt for understand coal mining industry.
文摘with the constant popularity of the precast assembly gasification, the application of the composite section beam which can change into different sections is wilder. This passage, based on the hypothesis that the interface is smooth, simplify the double composite section beam and deduce the anchorage-bolt-shear and composite-section-beam-bending-capacity formulas when there is a slip on the interface in elastic stage. Moreover, it contains some prospect and summarizes of the later research.