A building model with radiant cooling system was established and the cooling load, indoor temperature, surface temperature of the wails and other parameters in non-cooling and radiant cooling room were calculated by T...A building model with radiant cooling system was established and the cooling load, indoor temperature, surface temperature of the wails and other parameters in non-cooling and radiant cooling room were calculated by TRNSYS. The comparative analysis of the characteristics of attenuation and delay proves that the operation of radiant cooling system increases the degree of temperature attenuation of the room and reduces the inner surface temperature of the wall significantly, but has little effect on the attenuation coefficient and delay time of wall heat transfer. The simulation results also show that the inner surface temperature of the walls in the radiant cooling room is much lower than that in non-cooling room in the day with the maximum cooling load, which reduces the indoor operation temperature largely, and improves the thermal comfort. Finally, according to the analysis of indoor temperature of the rooms with different operation schedules of cooling system, it can be derived that the indoor mean temperature changes with the working time of radiant cooling system, and the operation schedule can be adjusted in practice according to the actual indoor temperature to achieve the integration of energy efficiency and thermal comfort.展开更多
Resource reservation protocols allow communicating hosts to reserve resources such as bandwidth to offer guaranteed service. However, current resource reservation architectures do not scale well for a large number of ...Resource reservation protocols allow communicating hosts to reserve resources such as bandwidth to offer guaranteed service. However, current resource reservation architectures do not scale well for a large number of flows. In this paper, we present a simple reservation protocol and a scalable admission control algorithm, which can provide QoS guarantees to individual flows without per-flow management in the network core. By mapping each flow to a definite time, this scheme addresses the problems that limit the effectiveness of current endpoint admission control schemes. The overall admission control process is described. Analysis is used to explain the reasonability of our scheme and simulation validates its performance.展开更多
基金Project(2010DFA72740) supported by the International Science & Technology Cooperation Program of China
文摘A building model with radiant cooling system was established and the cooling load, indoor temperature, surface temperature of the wails and other parameters in non-cooling and radiant cooling room were calculated by TRNSYS. The comparative analysis of the characteristics of attenuation and delay proves that the operation of radiant cooling system increases the degree of temperature attenuation of the room and reduces the inner surface temperature of the wall significantly, but has little effect on the attenuation coefficient and delay time of wall heat transfer. The simulation results also show that the inner surface temperature of the walls in the radiant cooling room is much lower than that in non-cooling room in the day with the maximum cooling load, which reduces the indoor operation temperature largely, and improves the thermal comfort. Finally, according to the analysis of indoor temperature of the rooms with different operation schedules of cooling system, it can be derived that the indoor mean temperature changes with the working time of radiant cooling system, and the operation schedule can be adjusted in practice according to the actual indoor temperature to achieve the integration of energy efficiency and thermal comfort.
文摘Resource reservation protocols allow communicating hosts to reserve resources such as bandwidth to offer guaranteed service. However, current resource reservation architectures do not scale well for a large number of flows. In this paper, we present a simple reservation protocol and a scalable admission control algorithm, which can provide QoS guarantees to individual flows without per-flow management in the network core. By mapping each flow to a definite time, this scheme addresses the problems that limit the effectiveness of current endpoint admission control schemes. The overall admission control process is described. Analysis is used to explain the reasonability of our scheme and simulation validates its performance.