An indirect expansion technique was proposed to measure the gas holdup in a non-transparent bubble column with 0.1 m inner diameter and height of 5.2 m.Air and distilled water were employed as gas and liquid phases,re...An indirect expansion technique was proposed to measure the gas holdup in a non-transparent bubble column with 0.1 m inner diameter and height of 5.2 m.Air and distilled water were employed as gas and liquid phases,respectively.The experimental results show that the average and maximum errors of gas holdup are less than 2% and 4.5%,respectively,between the indirect expansion and pressure drop methods at atmospheric or elevated pressure.Moreover,the gas holdup increases with operating pressure when the superficial gas velocity is a constant,while the effect of static liquid height on gas holdup can be ignored when the operating pressure and superficial gas velocity are fixed.展开更多
文摘An indirect expansion technique was proposed to measure the gas holdup in a non-transparent bubble column with 0.1 m inner diameter and height of 5.2 m.Air and distilled water were employed as gas and liquid phases,respectively.The experimental results show that the average and maximum errors of gas holdup are less than 2% and 4.5%,respectively,between the indirect expansion and pressure drop methods at atmospheric or elevated pressure.Moreover,the gas holdup increases with operating pressure when the superficial gas velocity is a constant,while the effect of static liquid height on gas holdup can be ignored when the operating pressure and superficial gas velocity are fixed.