期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
火力发电厂汽水水平直管道支吊架间距计算方法的探讨 被引量:2
1
作者 潘恒超 付祥卫 《吉林电力》 2003年第5期22-25,共4页
针对国内电力设计单位普遍使用的几种确定汽水水平直管道支吊架间距方法中存在的差异,进行对比分 析,指出其中部分规定不便于工程实际应用的不足之处;最后结合汽水管道实际的工作状态,提出笔者认为较为合 理的计算方法。
关键词 火力发电厂 汽水水平直管道 支吊架 间距计算方法 汽水管道
下载PDF
On the Connectivity of One-dimensional Vehicular Ad Hoc Networks 被引量:2
2
作者 Liao Jianxin Li Yuanzhen +2 位作者 Li Tonghong Zhu Xiaomin Zhang Lei 《China Communications》 SCIE CSCD 2010年第2期65-70,共6页
In this paper we analyze connectivity of one-dimensional Vehicular Ad Hoc Networks where vehicle gap distribution can be approximat- ed by an exponential distribution. The probabilities of Vehicular Ad Hoc Network con... In this paper we analyze connectivity of one-dimensional Vehicular Ad Hoc Networks where vehicle gap distribution can be approximat- ed by an exponential distribution. The probabilities of Vehicular Ad Hoc Network connectivity for difference cases are derived. Furthermore we proof that the nodes in a sub-interval [z1, z1 + △z] of interval [0,z],z 〉 0 where all the nodes are independently uniform distributed is a Poisson process and the relationship of Vehicle Ad hoc Networks and one-dimensional Ad Hoc networks where nodes independently uniform distributed in [zl, z1 + △z] is explained. The analysis is validated by computing the probability of network connectivity and comparing it with the Mont Carlo simu- lation results. 展开更多
关键词 Intelligent Transportation Systems (ITS) CONNECTIVITY Vehicular Ad Hoc Networks onedimensional Ad Hoc Networks
下载PDF
Long Distance GIL PD Fault Localization Method Based on Amplitude Difference and Time Difference Calculation of UHF Coupling Signal
3
作者 Zhang Hui Hu Po Tao Ke 《Journal of Mechanics Engineering and Automation》 2016年第1期39-46,共8页
In the long distance GIL under certain conditions, this paper researches and realizes detection of PD characters and accurate fault localization through UHF coupling sensors at different positions of the GIL pipeline.... In the long distance GIL under certain conditions, this paper researches and realizes detection of PD characters and accurate fault localization through UHF coupling sensors at different positions of the GIL pipeline. The main methods for the detection are UHF signal amplitude difference (DOA) and time difference (TOF). We analyze the localization error by using TE and TEM component and high order TE mode component in electromagnetic coaxial wave guide theory. Research and field test prove the DOA detection error can meet the requirements of real-time online diagnosis and for history tracking analysis. The error of TOF detection method can be controlled within 3% and can be applied to the site. 展开更多
关键词 GIL partial discharge UHF EM-wave amplitude difference time difference fault localization.
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部