The controlling algorithm was studied for the inverter-driven multi-type air conditioner using electronic expansion valve(EEV) in outdoor unit. The performance of inverter-driven air conditioner with two different uni...The controlling algorithm was studied for the inverter-driven multi-type air conditioner using electronic expansion valve(EEV) in outdoor unit. The performance of inverter-driven air conditioner with two different units was investigated by varying the outdoor ambient temperature and compressor speed. Based on the test results, the effect of EEV opening on the indoor unit exit superheat was discussed. For the specified outdoor ambient temperature scope and the EEV opening, the superheats of indoor units decrease with the outdoor ambient temperature rising. Improper distribution of refrigerant into each indoor unit will causes excessive superheat difference between two indoor units. Suggestions were then given for the controlling of the superheat.展开更多
In the last few years, transcatheter aortic valve implantation (TAVI) has become an alternative procedure in patients with severe aortic stenosis and high risk for surgical aortic replacement. Due to the anatomic co...In the last few years, transcatheter aortic valve implantation (TAVI) has become an alternative procedure in patients with severe aortic stenosis and high risk for surgical aortic replacement. Due to the anatomic correlation between aortic valve structure and conduction system of the heart, one of the most common complications after TAVI is conduction system disturbances which including bundle branch block, complete heart block and need for permanent pacemaker implantation. Although these disturbances are usually not lethal, they may have a great influence on patients' state and long term-survival. Several risk factors for conduction disturbances have been identified which including age, anatomy of the heart, periprocedural factors, type of implanted valve, preexisting abnormalities and comorbidities. As this technique becomes more familiar to physicians, patients should be carefully screened for risk factors for the development of conduction abnormalities after TAVI in order to provide effective prevention and proper treatment.展开更多
文摘The controlling algorithm was studied for the inverter-driven multi-type air conditioner using electronic expansion valve(EEV) in outdoor unit. The performance of inverter-driven air conditioner with two different units was investigated by varying the outdoor ambient temperature and compressor speed. Based on the test results, the effect of EEV opening on the indoor unit exit superheat was discussed. For the specified outdoor ambient temperature scope and the EEV opening, the superheats of indoor units decrease with the outdoor ambient temperature rising. Improper distribution of refrigerant into each indoor unit will causes excessive superheat difference between two indoor units. Suggestions were then given for the controlling of the superheat.
文摘In the last few years, transcatheter aortic valve implantation (TAVI) has become an alternative procedure in patients with severe aortic stenosis and high risk for surgical aortic replacement. Due to the anatomic correlation between aortic valve structure and conduction system of the heart, one of the most common complications after TAVI is conduction system disturbances which including bundle branch block, complete heart block and need for permanent pacemaker implantation. Although these disturbances are usually not lethal, they may have a great influence on patients' state and long term-survival. Several risk factors for conduction disturbances have been identified which including age, anatomy of the heart, periprocedural factors, type of implanted valve, preexisting abnormalities and comorbidities. As this technique becomes more familiar to physicians, patients should be carefully screened for risk factors for the development of conduction abnormalities after TAVI in order to provide effective prevention and proper treatment.