Four images of 1991 AVHRR, 2003 and 2007 MODIS were used to extract waterlogging inundated water of three years, and three inundated water maps were overlaid to estimate waterlogging affected frequency. Based on wa-te...Four images of 1991 AVHRR, 2003 and 2007 MODIS were used to extract waterlogging inundated water of three years, and three inundated water maps were overlaid to estimate waterlogging affected frequency. Based on wa-terlogging affected frequency, waterlogging hazard of pixel scale was assessed. According to the weighed score of area percentage of different waterlogging affected frequency in 13 counties/cities of Lixiahe region, waterlogging hazard rank of every county/city was assessed. Waterlogging affected frequency map and 1km×1km grid landuse map were used to assess waterlogging risk of pixel scale; and then waterlogging risk rank of every county/city was assessed by the similar method by which waterlogging hazard rank of every county/city was assessed. High risk region is located mainly in core zone of Lixiahe hinterland, medium risk region is adjacent to high risk region, and low risk region is located in the most outlying area of risk zone and mainly in south to middle part of Lixiahe region. Xinghua and Gaoyou belong to high risk city, Jiangyan belongs to medium risk city, and the other counties/cities have low or lower waterlogging risk. The method of assessing waterlogging risk in this paper is simple and applicable. This paper can provide guidance for the waterlogging risk analysis in broader area of Huaihe River Basin.展开更多
In the year of 2011, in the emergency reinforcement project of the main dike of Yangtze River in Luhe District, Nanjing City, four underground pipelines were vertically crossed with the embankment. In this project, ea...In the year of 2011, in the emergency reinforcement project of the main dike of Yangtze River in Luhe District, Nanjing City, four underground pipelines were vertically crossed with the embankment. In this project, each pipeline had been es- tablished independent culvert structure for protection and high pressure injection method had been used for the foundation treatment. To extend the length of the foot of slope and to improve the impermeable capacity of the dike, additional com- posite geomembranes had been installed in the riverside slope. By optimizing the construction program and enhancing the settlement observation during the constrution period, the safe operation of the pipelines had therefore been ensured.展开更多
The traffic condition of Taizhou Yangtze River Bridge is obtained to a certain extent, according to the traffic investigation nearby Taizhou Bridge. The statistical characteristics of the traffic conditions are acquir...The traffic condition of Taizhou Yangtze River Bridge is obtained to a certain extent, according to the traffic investigation nearby Taizhou Bridge. The statistical characteristics of the traffic conditions are acquired by statistical analysis. Simulation of the extreme vehicle loads and the sensitive analysis of load parameters are carried out based on these data complemented, which would guide the determination of the frictional coefficient between the main cables and the saddle.展开更多
The important role of Three Gorges Project (TGP) in the flood management of the Yangtze River Basin is summarized.The Optimal Regulation Schemes of the Three Gorge Reservoir is briefly described.The flood regulation e...The important role of Three Gorges Project (TGP) in the flood management of the Yangtze River Basin is summarized.The Optimal Regulation Schemes of the Three Gorge Reservoir is briefly described.The flood regulation effect of TGP is analyzed.Typical issues related to reservoir operation for flood regulation are discussed and suggestions are put forward for the future work.展开更多
The necessity of the main cable anticorrosion for suspension bridge is described, and operating principles and composition of main cable dehumidification system are analyzed. An idea using the waste heat of high tempe...The necessity of the main cable anticorrosion for suspension bridge is described, and operating principles and composition of main cable dehumidification system are analyzed. An idea using the waste heat of high temperature outlet air of dehumidification system to heat up regeneration air of rotary-type dehumidifier is put forward in this paper. The concrete scheme is to install a heat exchanger on air-out pipeline of roots blower and air-in pipeline of regeneration electric heater of rotary dehumidifier. Air preheated by the heat exchanger enters regeneration electric heater of rotary-type dehumidifier. Energy conservation of main cable dehumidification system for the Yangtze River highway bridge is calculated, and the results show that energy conservation rate can reach 44 %.展开更多
Schistosomiasis is a parasitic disease mostly found in areas along the Changjiang River of China. The disease is spread solely through an intermediary named oncomelania, so its spread of schistosomiasis can be control...Schistosomiasis is a parasitic disease mostly found in areas along the Changjiang River of China. The disease is spread solely through an intermediary named oncomelania, so its spread of schistosomiasis can be controlled by properly designing water intakes which prevent oncomelania from entering farming land or residential areas. This paper reports a successful design process and a new oncomelania free intake device. The design of the new intake is based on a sound research program in which extensive experimental studies were carried out to gain knowledge of oncomelania eco hydraulic behavior and detailed flow field information through CFD simulation.展开更多
基金Under the auspices of Ministry of Water Resources, P. R. China (No. [2001]29)
文摘Four images of 1991 AVHRR, 2003 and 2007 MODIS were used to extract waterlogging inundated water of three years, and three inundated water maps were overlaid to estimate waterlogging affected frequency. Based on wa-terlogging affected frequency, waterlogging hazard of pixel scale was assessed. According to the weighed score of area percentage of different waterlogging affected frequency in 13 counties/cities of Lixiahe region, waterlogging hazard rank of every county/city was assessed. Waterlogging affected frequency map and 1km×1km grid landuse map were used to assess waterlogging risk of pixel scale; and then waterlogging risk rank of every county/city was assessed by the similar method by which waterlogging hazard rank of every county/city was assessed. High risk region is located mainly in core zone of Lixiahe hinterland, medium risk region is adjacent to high risk region, and low risk region is located in the most outlying area of risk zone and mainly in south to middle part of Lixiahe region. Xinghua and Gaoyou belong to high risk city, Jiangyan belongs to medium risk city, and the other counties/cities have low or lower waterlogging risk. The method of assessing waterlogging risk in this paper is simple and applicable. This paper can provide guidance for the waterlogging risk analysis in broader area of Huaihe River Basin.
文摘In the year of 2011, in the emergency reinforcement project of the main dike of Yangtze River in Luhe District, Nanjing City, four underground pipelines were vertically crossed with the embankment. In this project, each pipeline had been es- tablished independent culvert structure for protection and high pressure injection method had been used for the foundation treatment. To extend the length of the foot of slope and to improve the impermeable capacity of the dike, additional com- posite geomembranes had been installed in the riverside slope. By optimizing the construction program and enhancing the settlement observation during the constrution period, the safe operation of the pipelines had therefore been ensured.
基金National Science and Technology Support Program of China ( No. 2009BAG15B02)Key Pro-grams for Science and Technology Development of Chinese Transportation Industry( No. 2008-353-332-180)
文摘The traffic condition of Taizhou Yangtze River Bridge is obtained to a certain extent, according to the traffic investigation nearby Taizhou Bridge. The statistical characteristics of the traffic conditions are acquired by statistical analysis. Simulation of the extreme vehicle loads and the sensitive analysis of load parameters are carried out based on these data complemented, which would guide the determination of the frictional coefficient between the main cables and the saddle.
文摘The important role of Three Gorges Project (TGP) in the flood management of the Yangtze River Basin is summarized.The Optimal Regulation Schemes of the Three Gorge Reservoir is briefly described.The flood regulation effect of TGP is analyzed.Typical issues related to reservoir operation for flood regulation are discussed and suggestions are put forward for the future work.
基金National Science and Technology Support Program of China ( No. 2009BAG15B01)Key Pro-grams for Science and Technology Development of Chinese Transportation Industry( No. 2008-353-332-170)
文摘The necessity of the main cable anticorrosion for suspension bridge is described, and operating principles and composition of main cable dehumidification system are analyzed. An idea using the waste heat of high temperature outlet air of dehumidification system to heat up regeneration air of rotary-type dehumidifier is put forward in this paper. The concrete scheme is to install a heat exchanger on air-out pipeline of roots blower and air-in pipeline of regeneration electric heater of rotary dehumidifier. Air preheated by the heat exchanger enters regeneration electric heater of rotary-type dehumidifier. Energy conservation of main cable dehumidification system for the Yangtze River highway bridge is calculated, and the results show that energy conservation rate can reach 44 %.
文摘Schistosomiasis is a parasitic disease mostly found in areas along the Changjiang River of China. The disease is spread solely through an intermediary named oncomelania, so its spread of schistosomiasis can be controlled by properly designing water intakes which prevent oncomelania from entering farming land or residential areas. This paper reports a successful design process and a new oncomelania free intake device. The design of the new intake is based on a sound research program in which extensive experimental studies were carried out to gain knowledge of oncomelania eco hydraulic behavior and detailed flow field information through CFD simulation.