期刊文献+
共找到1篇文章
< 1 >
每页显示 20 50 100
Shielding calculation for the thickness of the SR facility safety shutter
1
作者 YU Zheng-Ping LUO Wen-Yun CHEN Tao 《Nuclear Science and Techniques》 SCIE CAS CSCD 2006年第4期198-201,共4页
The safety shutter of the SR (synchrotron radiation) facility located at the front end of the facility is an in- dispensable component for radiation protection. Its thickness is decided by the gas bremsstrahlung produ... The safety shutter of the SR (synchrotron radiation) facility located at the front end of the facility is an in- dispensable component for radiation protection. Its thickness is decided by the gas bremsstrahlung produced in the SR facility storage ring by the interaction of electrons with the residual gas molecules in the vacuum chamber of the storage ring. In the calculation, the 3.5 GeV, 300 mA electron beam and a 15 m long insertion-device straight section (0.133 μ Pa) were taken into account, and the safety shutter was assumed to be located 12 m away from the end of the straight section. The EGSnrc code based on the Monte-Carlo method and empirical formulas were used, respectively, to calculate the thickness to satisfy the shielding requirement of the safety shutter at the front end of the SR facility, and the results were compared and the availability of EGSnrc was proved. 展开更多
关键词 同步加速器辐射设备 防火档板 蒙特卡洛法 厚度
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部