It is of great significance to make comparative analyses of seismic fortification criteria at home and abroad for improving the anti-seismic capability of electrical equipment and revising the relevant national standa...It is of great significance to make comparative analyses of seismic fortification criteria at home and abroad for improving the anti-seismic capability of electrical equipment and revising the relevant national standards.A brief overview of American,Japanese,IEC standards and Chinese seismic design codes for electrical equipment is presented.Differences between these seismic fortification standards of electrical equipment are compared and analyzed in respect of the goal and level of seismic fortification and the seismic design spectrum.The advantages and disadvantages of Chinese standards are pointed out.Through learning from foreign experience on the determination of seismic fortification standards,recommendations are made for the improvement and revision of Chinese seismic fortification standards for electrical equipment.展开更多
Nowadays, PD (partial discharge) measurements are a crucial part of the preventive maintenance of electrical equipment within high voltage engineering. Especially for electrical machines, both the supplier and the u...Nowadays, PD (partial discharge) measurements are a crucial part of the preventive maintenance of electrical equipment within high voltage engineering. Especially for electrical machines, both the supplier and the user are interested in the results of PD measurements. However, PDs hardly represent the cause of the failure, more likely they are claimed as the outcome of a failure. This paper deals with the insulation of a 6 kV electrical machine, whereas PD measurements were carried out at a single stator from wound coils. During manufacturing, these coils were equipped with different materials for the OCP (outer corona protection). Using different PD measurement systems and different bandwidths, investigations of the PD behavior of the coils were carried out. Additionally, the surface resistivity of the corona protection was determined. As a result, conclusions for the correlations between the resistance of the OCP as well as the PD behavior are stated. Furthermore, the influence of using different measurement systems, different measuring circuits, and different bandwidths is shown.展开更多
基金funded by the special project of Spark Program of Earthquake Sciences (Serial number:XH12063)
文摘It is of great significance to make comparative analyses of seismic fortification criteria at home and abroad for improving the anti-seismic capability of electrical equipment and revising the relevant national standards.A brief overview of American,Japanese,IEC standards and Chinese seismic design codes for electrical equipment is presented.Differences between these seismic fortification standards of electrical equipment are compared and analyzed in respect of the goal and level of seismic fortification and the seismic design spectrum.The advantages and disadvantages of Chinese standards are pointed out.Through learning from foreign experience on the determination of seismic fortification standards,recommendations are made for the improvement and revision of Chinese seismic fortification standards for electrical equipment.
文摘Nowadays, PD (partial discharge) measurements are a crucial part of the preventive maintenance of electrical equipment within high voltage engineering. Especially for electrical machines, both the supplier and the user are interested in the results of PD measurements. However, PDs hardly represent the cause of the failure, more likely they are claimed as the outcome of a failure. This paper deals with the insulation of a 6 kV electrical machine, whereas PD measurements were carried out at a single stator from wound coils. During manufacturing, these coils were equipped with different materials for the OCP (outer corona protection). Using different PD measurement systems and different bandwidths, investigations of the PD behavior of the coils were carried out. Additionally, the surface resistivity of the corona protection was determined. As a result, conclusions for the correlations between the resistance of the OCP as well as the PD behavior are stated. Furthermore, the influence of using different measurement systems, different measuring circuits, and different bandwidths is shown.