The impedance of a solid state active phased array antenna varing with frequency and beam scanning scanning angle be matched with the solid state active matching network (SSAMN). In order to adjust and measure the rad...The impedance of a solid state active phased array antenna varing with frequency and beam scanning scanning angle be matched with the solid state active matching network (SSAMN). In order to adjust and measure the radar conveniently and Securely, it is necessary for the impedance of the simulator of the phased array antennas to be optimized.Having selected the PIN dilde controlling circuits and the circuit parameters optimized,the simulator circuit is determined through numerical computation The experiment is given in support of the simulation.展开更多
This paper presents an acoustic design sensitivity(ADS)analysis on sound radiation of structures by using the boundary element method(BEM).We calculated the velocity distribution of the thin plate by analytical method...This paper presents an acoustic design sensitivity(ADS)analysis on sound radiation of structures by using the boundary element method(BEM).We calculated the velocity distribution of the thin plate by analytical method and the surface sound pressure by Rayleigh integral,and expressed the sound radiation power of the structure in a positive definite quadratic form of the Hermitian with an impedance matrix.The ADS analysis of the plate was thus translated into the analysis of structure dynamic sensitivity and ...展开更多
A 16 × 16 micro-strip antenna array with high gain characteristic was proposed for the 5.5 GHz W/MAX application. The T-junctions with a power ratio of 2 : 1 were used to design the feed network. To correct the ...A 16 × 16 micro-strip antenna array with high gain characteristic was proposed for the 5.5 GHz W/MAX application. The T-junctions with a power ratio of 2 : 1 were used to design the feed network. To correct the stepped discontinuity of impedance change in common multi-section impedance transformer, exponential line matching trans- formers were adopted in the WiMAX frequency band. The reflection coefficient was lower than - 15 dB from 5.08 GHz to 5.87 GHz. The measured gain of the antenna array achieved 29.8 dBi on E-plane at 5.8 GHz.展开更多
In this paper a practical but sufficiently accurate method of calculating transient components in short circuit currents and voltages is proposed. It enables to find the roots of the chara...In this paper a practical but sufficiently accurate method of calculating transient components in short circuit currents and voltages is proposed. It enables to find the roots of the characteristic equation of high order without forming and solving it. This method is convenient to use especially in case of complicated expansionary power systems.展开更多
OBJECTIVE: To better understand the working mechanism of acupuncture, we investigated the skin electrical impedance distribution around acupoints, and the impedance changes at 12 original acupoints bilaterally after b...OBJECTIVE: To better understand the working mechanism of acupuncture, we investigated the skin electrical impedance distribution around acupoints, and the impedance changes at 12 original acupoints bilaterally after bending the limbs.METHODS: We measured the skin electrical impedance in three study subjects in the frequency range of 40 to 10 k Hz using the four-electrode method with a sharp probe and a large reference electrode.A measurement matrix of 7 mm × 7 mm with spacing of 2.0(or 3.0) mm was measured to obtain 2 D impedance mapping of acupoints. The impedance spectra of 12 original acupoints were measured at the 0° position and the 90° position.RESULTS: The electrical impedance of some acupoints, such as Yangchi(TE 4), was 16 times lower than that of the surrounding area, showing a recognizable small central area of low impedance with a diameter of less than 4 mm. In contrast, other acupoints, such as Laogong(PC 8), had an electrical impedance that was not significantly different from that of the surrounding area. When the limb was bent from a straight position(0o) to a vertical position(90o), the electrical impedance of the 12 original acupoints showed varied trends, either increasing or decreasing by a factor of up to ten times, or remaining at the same level.CONCLUSION: Not all acupoints tested show the property of low impedance, which might be related to the varied depth of the openings of superficial collaterals. The unexpected dependence of acupoint impedance on limb angle is a novel discovery, which implies that the channel paths are located in interstitial structures in the limbs. It might be possible to determine an optimized limb position for each particular acupuncture treatment in clinical practice.展开更多
文摘The impedance of a solid state active phased array antenna varing with frequency and beam scanning scanning angle be matched with the solid state active matching network (SSAMN). In order to adjust and measure the radar conveniently and Securely, it is necessary for the impedance of the simulator of the phased array antennas to be optimized.Having selected the PIN dilde controlling circuits and the circuit parameters optimized,the simulator circuit is determined through numerical computation The experiment is given in support of the simulation.
基金Funded by Doctoral Program Foundation of Institutions of Higher Education of China(20070487403)Natural Science Foundation of Hubei Province of China(2006ABA71)
文摘This paper presents an acoustic design sensitivity(ADS)analysis on sound radiation of structures by using the boundary element method(BEM).We calculated the velocity distribution of the thin plate by analytical method and the surface sound pressure by Rayleigh integral,and expressed the sound radiation power of the structure in a positive definite quadratic form of the Hermitian with an impedance matrix.The ADS analysis of the plate was thus translated into the analysis of structure dynamic sensitivity and ...
基金Supported by the National Natural Science Foundation of China(No.60777014)the Specialized Research Fund for the Doctoral Program of Higher Education of China(No.20090032110027)
文摘A 16 × 16 micro-strip antenna array with high gain characteristic was proposed for the 5.5 GHz W/MAX application. The T-junctions with a power ratio of 2 : 1 were used to design the feed network. To correct the stepped discontinuity of impedance change in common multi-section impedance transformer, exponential line matching trans- formers were adopted in the WiMAX frequency band. The reflection coefficient was lower than - 15 dB from 5.08 GHz to 5.87 GHz. The measured gain of the antenna array achieved 29.8 dBi on E-plane at 5.8 GHz.
文摘In this paper a practical but sufficiently accurate method of calculating transient components in short circuit currents and voltages is proposed. It enables to find the roots of the characteristic equation of high order without forming and solving it. This method is convenient to use especially in case of complicated expansionary power systems.
基金Supported by the National Natural Science Foundation of China(No.11374016,No.91221202)Medicineschool of electronics engineering and computer science Joint Seed Fund 2016,Peking University
文摘OBJECTIVE: To better understand the working mechanism of acupuncture, we investigated the skin electrical impedance distribution around acupoints, and the impedance changes at 12 original acupoints bilaterally after bending the limbs.METHODS: We measured the skin electrical impedance in three study subjects in the frequency range of 40 to 10 k Hz using the four-electrode method with a sharp probe and a large reference electrode.A measurement matrix of 7 mm × 7 mm with spacing of 2.0(or 3.0) mm was measured to obtain 2 D impedance mapping of acupoints. The impedance spectra of 12 original acupoints were measured at the 0° position and the 90° position.RESULTS: The electrical impedance of some acupoints, such as Yangchi(TE 4), was 16 times lower than that of the surrounding area, showing a recognizable small central area of low impedance with a diameter of less than 4 mm. In contrast, other acupoints, such as Laogong(PC 8), had an electrical impedance that was not significantly different from that of the surrounding area. When the limb was bent from a straight position(0o) to a vertical position(90o), the electrical impedance of the 12 original acupoints showed varied trends, either increasing or decreasing by a factor of up to ten times, or remaining at the same level.CONCLUSION: Not all acupoints tested show the property of low impedance, which might be related to the varied depth of the openings of superficial collaterals. The unexpected dependence of acupoint impedance on limb angle is a novel discovery, which implies that the channel paths are located in interstitial structures in the limbs. It might be possible to determine an optimized limb position for each particular acupuncture treatment in clinical practice.