The experimental study of natural convection in allglass evacuated tube solar collectors is performed through the experimental platform of the solar-assisted fuel cell system.The experimental facility includes solar c...The experimental study of natural convection in allglass evacuated tube solar collectors is performed through the experimental platform of the solar-assisted fuel cell system.The experimental facility includes solar collectors with different length and diameter tubes, different coating materials, and with / without guide plates, respectively. Threedimensional mathematical models on natural and forced convections in the solar collectors are established and the experimental data is validated by field synergy and entransy principles. The results of natural convection show that the water temperature increases and thermal efficiency decreases gradually with the evacuated tube length. The thermal efficiency increases when absorption rates increase from 0. 95 to 1. 0 and emission rates decrease from 0. 16 to 0. 06. The thermal efficiency of solar collectors is increased after being equipped with the guide plate, which is attributed to the disappearance of the mixed flowand the enhancement of the heat transfer at the bottom of the evacuated tube. The results of forced convertion indicate that the Reynolds, Nusselt and entransy increments of the horizontal double collectors are higher than those of the vertical single collector while the entransy dissipation is lower than that of the vertical single collector. It is concluded that the solar collectors with guide plates are suitable for natural convection while the double horizontal collectors are suitable for forced convection in the thermal field of solar-assisted fuel cell systems with lowand medium temperatures.展开更多
In this article,the effect of using water/zinc oxide nanofluid as a working fluid on the performance of solar collector is investigated experimentally.The volumetric concentration of nanoparticles is 0.4%,and the part...In this article,the effect of using water/zinc oxide nanofluid as a working fluid on the performance of solar collector is investigated experimentally.The volumetric concentration of nanoparticles is 0.4%,and the particle size is 40 nm,and the mass flow rate of the fluid varies from 1 to 3 kg/min.For this experiment,a device has been prepared with appropriate measuring instruments whose energy source is solar radiation.The solar energy absorbed by the flat plate collector is absorbed by the nanofluid of water/zinc oxide.The nanofluid is pumped to the consumer,a heat exchanger,where it heats the water.The temperature,radiation level,flow rate,and pressure in different parts of the device were measured.The pressure drop and the heat transferred are the most important results of this experimental work.The ASHRAE standard is used to calculate efficiency.The results showed that the use of water/zinc oxide nanofluid increases the collector performance compared to water.For 1 kg/min of mass flow rate,the nanofluids have a 16% increase in efficiency compared to water.From the results,it can be concluded that the choice of optimum mass flow rate in both water and nanofluid cases increases efficiency.展开更多
In this paper,the performance of a solar thermal system with a focus on space heating was investigated.A 70 m^(2) detached house was considered in the weather conditions of the city of Tehran,Iran.A thermosyphon solar...In this paper,the performance of a solar thermal system with a focus on space heating was investigated.A 70 m^(2) detached house was considered in the weather conditions of the city of Tehran,Iran.A thermosyphon solar water heater with a flat plate collector combined with an auxiliary electrical heater supplies the heating demand of the house.The proposed system was modeled and analyzed using TRNSYS software.In this regard,the TRNBuild module was employed for the building load calculation.The model has been simulated for one year of operation.The effects of the solar collector’s surface area and storage volume were assessed.The results show that for a solar collector with a 15 m^(2) surface area,the solar fraction is 0.29 in January,during which the solar radiation is the lowest.Using solar collectors of10 m^(2) and 5 m^(2) surface areas,the solar fraction falls to 0.23 and 0.14,respectively in January.Besides,two cases of 150 L and 300 L storage tanks are taken into account.Eventually,it is found that using a 15 m^(2) solar collector and a 150 L storage tank can appropriately provide the building’ s heating demand taking the thermal performance and economic aspects into consideration.展开更多
Temperature distribution over the absorber plate of a parallel flow flat-plate solar collector is numerically analyzed. The governing differential equations with boundary conditions are solved numerically using fluent...Temperature distribution over the absorber plate of a parallel flow flat-plate solar collector is numerically analyzed. The governing differential equations with boundary conditions are solved numerically using fluent software. Effects of the inlet mass flux, inlet temperature and tube spacing on velocity and temperature distributions are discussed. Numerical results show that the distributions of velocity and temperature of fluid is unsymmetrical inside pipe.展开更多
The influence of a heterojunction in the vicinity of a graded BC junction on the performance of npn SiGe HBTs is studied. SiGe HBTs differing only in heterojunction position in the vicinity of a graded BC junction are...The influence of a heterojunction in the vicinity of a graded BC junction on the performance of npn SiGe HBTs is studied. SiGe HBTs differing only in heterojunction position in the vicinity of a graded BC junction are simulated by means of 2D Medici software for DC current gain and frequency characteristics. In addition, the simulated DC current gains and cut-off frequencies are compared at different collector-emitter bias voltages. Through the simulation results, both DC and HF device performance are found to be strongly impacted by degree of confinement of the neutral base in the SiGe layer, even in the absence of a conduction band barrier. This conclusion is of significance for designing and analyzing SiGe HBTs.展开更多
This paper explores the integrated utilization of low-grade thermal energy in hot coal mines, based on analysis of original heating, refrigerating, mine draining, bath draining and air exhaust systems, and in combinat...This paper explores the integrated utilization of low-grade thermal energy in hot coal mines, based on analysis of original heating, refrigerating, mine draining, bath draining and air exhaust systems, and in combination with the actual conditions of Tangkou Coal Mine in Shandong Province. It presents a set of comprehensive and integrated utilization schemes for the various different kinds of low quality heat energy. With heat pumps, the recycling of the low quality heat energy from the drainage, bathing water and the exhaust air can occur in winter, and in summer, there exists condensed heat of the refrigerating system. When in conjunction with solar collectors, the thermal utilization of solar power can be realized for the whole year. The system achieves mine drainage and bathing water purification and recycling, as well as purifying exhaust air by water spraying. It also satisfies the demands of a whole year's bathing heat for the coal mine, with refrigeration in summer, and heating for the ground house and shaft house in winter. It is able to integrate different kinds of low quality heat energy and low emission drainage and dust, and can replace the traditional boiler heating system. Finally, the system reduces conventional energy consumption and the amount of mine water drainage.展开更多
Availability of clean water is going to become one of biggest demands of the country. Even though there arc various technologies available for purification of water harnessing solar energy fits the purpose for future ...Availability of clean water is going to become one of biggest demands of the country. Even though there arc various technologies available for purification of water harnessing solar energy fits the purpose for future problems. Distillation is one of many processes available for water purification, and solar energy is one of several forms of heat energy that can be used to energize this process. In this review a study is made to enhance the productivity of the solar stills by connecting solar still with latent heat storage and solar air heater in series and other factors like improving evaporation rate by maintaining Low depth, more exposure area, heat addition by solar collector and presence of latent heat storage material, which is a paraffin wax as a integral part of still. Latent heat storage is one of the most efficient ways of storing thermal energy. Unlike the sensible heat storage method, the latent heat storage method provides much higher storage density, with a smaller temperature difference between storing and releasing heat. Further augmentation of the yield by scraps, pebble, and sand are added.展开更多
In order to increase the efficiency of solar collector, a methodology is proposed based on the analysis of its influencing factors, such as thermal conductivity of filled layer, structure forms of filled layer and hea...In order to increase the efficiency of solar collector, a methodology is proposed based on the analysis of its influencing factors, such as thermal conductivity of filled layer, structure forms of filled layer and heat loss coefficient. The results of analysis show that the heat transfer between pipes in evacuated tube is one of the most important factors, which can lead to the decrease of the outlet temperature of working fluid. In order to eliminate the negative influence of the heat transfer between pipes, the hollow filled-type evacuated tube with U-tube(HUFET) was developed, and the heat transfer characteristics of HUFET were analyzed by theoretical and experimental studies. The results show that the thermal resistances decrease with the increase of the thermal conductivity of filled layer. When the thermal conductivity is over 10 W/(m·K), the change of thermal resistances is very little.Furthermore, the larger the thermal conductivity of filled layer, the less the rate of the energy transfer between the two pipes to the total energy transfer, which is between the absorber tube and the working fluid. There is a little difference between the efficiencies of HUFET and UFET, with the efficiency of HUFET 2.4% higher than that of UFET. Meanwhile, the validation of the model developed was confirmed by the experiment.展开更多
In this research paper, an attempt has been made to come across the effect of distance between double glazing on the efficiency of a solar thermal collector. Experiments were carded out on an active solar energy demon...In this research paper, an attempt has been made to come across the effect of distance between double glazing on the efficiency of a solar thermal collector. Experiments were carded out on an active solar energy demonstration system (ET 200). Commercial glass pane of 3 mm thick having the same dimensions as that of the apparatus was placed above the collector at a distance of 2 cm, 4 cm and 6 cm. Tests were done with and without the added glass. Experiments were performed for double glazing with two positions of the light meter. In one position, it was placed in the middle of the collector surface. While, in the other one, the light meter was placed in the middle of the added glass. To study the effect of double glazing on the performance of the solar collector ET 200, the correct position of the light meter was to place it exactly in the middle of the additional pane under the lamp. Double glazing does not enhance the performance of the solar collector because of the high resistance of the system glass air glass. The efficiency of double glazing solar collector decreases with the increasing the distance of the two separated glasses.展开更多
基金The National Natural Science Foundation of China(No.51376110,51541604)the Major International(Regional) Joint Research Project of the National Natural Science Foundation of China(No.61320106011)
文摘The experimental study of natural convection in allglass evacuated tube solar collectors is performed through the experimental platform of the solar-assisted fuel cell system.The experimental facility includes solar collectors with different length and diameter tubes, different coating materials, and with / without guide plates, respectively. Threedimensional mathematical models on natural and forced convections in the solar collectors are established and the experimental data is validated by field synergy and entransy principles. The results of natural convection show that the water temperature increases and thermal efficiency decreases gradually with the evacuated tube length. The thermal efficiency increases when absorption rates increase from 0. 95 to 1. 0 and emission rates decrease from 0. 16 to 0. 06. The thermal efficiency of solar collectors is increased after being equipped with the guide plate, which is attributed to the disappearance of the mixed flowand the enhancement of the heat transfer at the bottom of the evacuated tube. The results of forced convertion indicate that the Reynolds, Nusselt and entransy increments of the horizontal double collectors are higher than those of the vertical single collector while the entransy dissipation is lower than that of the vertical single collector. It is concluded that the solar collectors with guide plates are suitable for natural convection while the double horizontal collectors are suitable for forced convection in the thermal field of solar-assisted fuel cell systems with lowand medium temperatures.
文摘In this article,the effect of using water/zinc oxide nanofluid as a working fluid on the performance of solar collector is investigated experimentally.The volumetric concentration of nanoparticles is 0.4%,and the particle size is 40 nm,and the mass flow rate of the fluid varies from 1 to 3 kg/min.For this experiment,a device has been prepared with appropriate measuring instruments whose energy source is solar radiation.The solar energy absorbed by the flat plate collector is absorbed by the nanofluid of water/zinc oxide.The nanofluid is pumped to the consumer,a heat exchanger,where it heats the water.The temperature,radiation level,flow rate,and pressure in different parts of the device were measured.The pressure drop and the heat transferred are the most important results of this experimental work.The ASHRAE standard is used to calculate efficiency.The results showed that the use of water/zinc oxide nanofluid increases the collector performance compared to water.For 1 kg/min of mass flow rate,the nanofluids have a 16% increase in efficiency compared to water.From the results,it can be concluded that the choice of optimum mass flow rate in both water and nanofluid cases increases efficiency.
文摘In this paper,the performance of a solar thermal system with a focus on space heating was investigated.A 70 m^(2) detached house was considered in the weather conditions of the city of Tehran,Iran.A thermosyphon solar water heater with a flat plate collector combined with an auxiliary electrical heater supplies the heating demand of the house.The proposed system was modeled and analyzed using TRNSYS software.In this regard,the TRNBuild module was employed for the building load calculation.The model has been simulated for one year of operation.The effects of the solar collector’s surface area and storage volume were assessed.The results show that for a solar collector with a 15 m^(2) surface area,the solar fraction is 0.29 in January,during which the solar radiation is the lowest.Using solar collectors of10 m^(2) and 5 m^(2) surface areas,the solar fraction falls to 0.23 and 0.14,respectively in January.Besides,two cases of 150 L and 300 L storage tanks are taken into account.Eventually,it is found that using a 15 m^(2) solar collector and a 150 L storage tank can appropriately provide the building’ s heating demand taking the thermal performance and economic aspects into consideration.
文摘Temperature distribution over the absorber plate of a parallel flow flat-plate solar collector is numerically analyzed. The governing differential equations with boundary conditions are solved numerically using fluent software. Effects of the inlet mass flux, inlet temperature and tube spacing on velocity and temperature distributions are discussed. Numerical results show that the distributions of velocity and temperature of fluid is unsymmetrical inside pipe.
文摘The influence of a heterojunction in the vicinity of a graded BC junction on the performance of npn SiGe HBTs is studied. SiGe HBTs differing only in heterojunction position in the vicinity of a graded BC junction are simulated by means of 2D Medici software for DC current gain and frequency characteristics. In addition, the simulated DC current gains and cut-off frequencies are compared at different collector-emitter bias voltages. Through the simulation results, both DC and HF device performance are found to be strongly impacted by degree of confinement of the neutral base in the SiGe layer, even in the absence of a conduction band barrier. This conclusion is of significance for designing and analyzing SiGe HBTs.
文摘This paper explores the integrated utilization of low-grade thermal energy in hot coal mines, based on analysis of original heating, refrigerating, mine draining, bath draining and air exhaust systems, and in combination with the actual conditions of Tangkou Coal Mine in Shandong Province. It presents a set of comprehensive and integrated utilization schemes for the various different kinds of low quality heat energy. With heat pumps, the recycling of the low quality heat energy from the drainage, bathing water and the exhaust air can occur in winter, and in summer, there exists condensed heat of the refrigerating system. When in conjunction with solar collectors, the thermal utilization of solar power can be realized for the whole year. The system achieves mine drainage and bathing water purification and recycling, as well as purifying exhaust air by water spraying. It also satisfies the demands of a whole year's bathing heat for the coal mine, with refrigeration in summer, and heating for the ground house and shaft house in winter. It is able to integrate different kinds of low quality heat energy and low emission drainage and dust, and can replace the traditional boiler heating system. Finally, the system reduces conventional energy consumption and the amount of mine water drainage.
文摘Availability of clean water is going to become one of biggest demands of the country. Even though there arc various technologies available for purification of water harnessing solar energy fits the purpose for future problems. Distillation is one of many processes available for water purification, and solar energy is one of several forms of heat energy that can be used to energize this process. In this review a study is made to enhance the productivity of the solar stills by connecting solar still with latent heat storage and solar air heater in series and other factors like improving evaporation rate by maintaining Low depth, more exposure area, heat addition by solar collector and presence of latent heat storage material, which is a paraffin wax as a integral part of still. Latent heat storage is one of the most efficient ways of storing thermal energy. Unlike the sensible heat storage method, the latent heat storage method provides much higher storage density, with a smaller temperature difference between storing and releasing heat. Further augmentation of the yield by scraps, pebble, and sand are added.
基金Projects(2011BAJ03B12-3,2013BAJ10B02-03) supported by the National Science and Technology Program during the 12th Five-year Plan Period,ChinaProject(51378005) supported by the National Natural Science Foundation,China+1 种基金Projects(DUT14RC(3)123,DUT14RC(3)129) supported by Fundamental Research Funds for the Dalian University of Tecnology,ChinaProject(DUT14ZD210) supported by the Fundamental Research Funds for the Central Universities of China
文摘In order to increase the efficiency of solar collector, a methodology is proposed based on the analysis of its influencing factors, such as thermal conductivity of filled layer, structure forms of filled layer and heat loss coefficient. The results of analysis show that the heat transfer between pipes in evacuated tube is one of the most important factors, which can lead to the decrease of the outlet temperature of working fluid. In order to eliminate the negative influence of the heat transfer between pipes, the hollow filled-type evacuated tube with U-tube(HUFET) was developed, and the heat transfer characteristics of HUFET were analyzed by theoretical and experimental studies. The results show that the thermal resistances decrease with the increase of the thermal conductivity of filled layer. When the thermal conductivity is over 10 W/(m·K), the change of thermal resistances is very little.Furthermore, the larger the thermal conductivity of filled layer, the less the rate of the energy transfer between the two pipes to the total energy transfer, which is between the absorber tube and the working fluid. There is a little difference between the efficiencies of HUFET and UFET, with the efficiency of HUFET 2.4% higher than that of UFET. Meanwhile, the validation of the model developed was confirmed by the experiment.
文摘In this research paper, an attempt has been made to come across the effect of distance between double glazing on the efficiency of a solar thermal collector. Experiments were carded out on an active solar energy demonstration system (ET 200). Commercial glass pane of 3 mm thick having the same dimensions as that of the apparatus was placed above the collector at a distance of 2 cm, 4 cm and 6 cm. Tests were done with and without the added glass. Experiments were performed for double glazing with two positions of the light meter. In one position, it was placed in the middle of the collector surface. While, in the other one, the light meter was placed in the middle of the added glass. To study the effect of double glazing on the performance of the solar collector ET 200, the correct position of the light meter was to place it exactly in the middle of the additional pane under the lamp. Double glazing does not enhance the performance of the solar collector because of the high resistance of the system glass air glass. The efficiency of double glazing solar collector decreases with the increasing the distance of the two separated glasses.