Extracting geometric data of landmarks from fluoroscopic images plays an important role in camera calibration process of a fluoroscopic-image-based surgical navigation system. Connected components labeling is the esse...Extracting geometric data of landmarks from fluoroscopic images plays an important role in camera calibration process of a fluoroscopic-image-based surgical navigation system. Connected components labeling is the essential technique for the extraction. A new fast connected components labeling algorithm was presented. The definition of upward concave set was introduced to explain the algorithm. Feasibility and efficiency of the algorithm were verified with experiments. This algorithm performs well in labeling non-upward concave set connected components and applies to landmarks labeling well. Moreover, the proposed algorithm possesses a desirable characteristic that will facilitate the subsequent processing of fluoroscopic images.展开更多
Harmonic suppression, non-periodic and non-closing in straightness profile error that will bring about harmonic component distortion in measurement result are analyzed. The countermeasure-a novel accurate two-probe me...Harmonic suppression, non-periodic and non-closing in straightness profile error that will bring about harmonic component distortion in measurement result are analyzed. The countermeasure-a novel accurate two-probe method in time domain is put forward to measure straight-going component motion error in machine tools based on the frequency domain 3-point method after symmetrical continuation of probes' primitive signal. Both straight-going component motion error in machine tools and the profile error in workpiece that is manufactured on this machine can be measured at the same time. The information is available to diagnose the fault origin of machine tools. The analysis result is proved to be correct by the experiment.展开更多
基金Projectof Science and Technology Committee of Shanghai Municipality(No2528(3))
文摘Extracting geometric data of landmarks from fluoroscopic images plays an important role in camera calibration process of a fluoroscopic-image-based surgical navigation system. Connected components labeling is the essential technique for the extraction. A new fast connected components labeling algorithm was presented. The definition of upward concave set was introduced to explain the algorithm. Feasibility and efficiency of the algorithm were verified with experiments. This algorithm performs well in labeling non-upward concave set connected components and applies to landmarks labeling well. Moreover, the proposed algorithm possesses a desirable characteristic that will facilitate the subsequent processing of fluoroscopic images.
基金National Nature Science Foundation of China.No.50075056
文摘Harmonic suppression, non-periodic and non-closing in straightness profile error that will bring about harmonic component distortion in measurement result are analyzed. The countermeasure-a novel accurate two-probe method in time domain is put forward to measure straight-going component motion error in machine tools based on the frequency domain 3-point method after symmetrical continuation of probes' primitive signal. Both straight-going component motion error in machine tools and the profile error in workpiece that is manufactured on this machine can be measured at the same time. The information is available to diagnose the fault origin of machine tools. The analysis result is proved to be correct by the experiment.