Aim To prepare a self-emulsifying microemulsion of 9-nitrocamptothecin (9-NC ME) for intravenous injection and investi- gation of its pharmacokinetic profiles in normal SD rats. Methods 9-NC ME was optimized in term...Aim To prepare a self-emulsifying microemulsion of 9-nitrocamptothecin (9-NC ME) for intravenous injection and investi- gation of its pharmacokinetic profiles in normal SD rats. Methods 9-NC ME was optimized in terms of droplet size and lack of drug precipitation following aqueous dilution using a pseudo-ternary phase diagram. Physicochemical properties of 9-NC ME were evaluated. 9-NC ME was intravenously administered via tail vein in healthy rats. Results A stable microemulsion was formulated consisted of soybean oil as oil phase, EPC/Tween-80 as emulsifier, and anhydrous ethanol as co-emulsifier. The droplets of the microemulsion were spherical shape with mean diameter of 38.3 ± 4.0 nm after 1:20 dilution with 5% glucose injection. The pharmacokinetic parameters of 9-NC ME after intravenous administration in rats were t1/2 of 0.97 ± 0.14 h, A UC0-8 of 372.77 ±49.62 ng·h·mL^-1 and MRT of 1.40 ± 0.21 h which were 1.4-fold, 1.65-fold, and 1.4-fold more than those of 9-NC solution (P〈0.01). Conclusion The results suggested that 9-NC ME was a promising drug delivery system and it was expected to provide a novel 9-NC injection for cancer patients.展开更多
Objective: The aim of this study was to compare the anatomic-landmark and ultrasound-guided techniques in the placement of an internal jugular vein port in patients with advanced breast cancer. Methods: Between Marc...Objective: The aim of this study was to compare the anatomic-landmark and ultrasound-guided techniques in the placement of an internal jugular vein port in patients with advanced breast cancer. Methods: Between March 2010 and October 2010, 60 patients with advanced breast cancer underwent central venous port placement for the delivery of chemotherapy, preferably through the internal jugular vein. Patients were randomly assigned to either the anatomic-landmark or the ultrasound-guided group. Failure on first attempt, number of attempts until successful catheterization, time to successful placement, the accordance of the two placement approaches, and the demographics of each patient were recorded. Results: The consistency of the direction of two lines drawn using the anatomic-landmark and ultrasound-guided techniques or of the diameter of the internal jugular vein as determined by the two approaches was 85% (51/60). The rate of successful place- ment at first attempt was higher in the ultrasound group than in the anatomic-landmark group (P 〈 0.05). A greater number of attempts and longer time to successful port placement were needed in the latter (P 〈 0.05). Conclusion: The findings of this study indicate that, in the placement of an internal jugular vein port, the ultrasound (US)-guJded technique has several advantages over the anatomic-landmark technique.展开更多
基金National Natural Science Foundation of China (GrantNo.30430760)the 985 projects (Phase II) of the State Key Labo-ratory of Natural and Biomimetic Drugs (Peking University, China).
文摘Aim To prepare a self-emulsifying microemulsion of 9-nitrocamptothecin (9-NC ME) for intravenous injection and investi- gation of its pharmacokinetic profiles in normal SD rats. Methods 9-NC ME was optimized in terms of droplet size and lack of drug precipitation following aqueous dilution using a pseudo-ternary phase diagram. Physicochemical properties of 9-NC ME were evaluated. 9-NC ME was intravenously administered via tail vein in healthy rats. Results A stable microemulsion was formulated consisted of soybean oil as oil phase, EPC/Tween-80 as emulsifier, and anhydrous ethanol as co-emulsifier. The droplets of the microemulsion were spherical shape with mean diameter of 38.3 ± 4.0 nm after 1:20 dilution with 5% glucose injection. The pharmacokinetic parameters of 9-NC ME after intravenous administration in rats were t1/2 of 0.97 ± 0.14 h, A UC0-8 of 372.77 ±49.62 ng·h·mL^-1 and MRT of 1.40 ± 0.21 h which were 1.4-fold, 1.65-fold, and 1.4-fold more than those of 9-NC solution (P〈0.01). Conclusion The results suggested that 9-NC ME was a promising drug delivery system and it was expected to provide a novel 9-NC injection for cancer patients.
文摘Objective: The aim of this study was to compare the anatomic-landmark and ultrasound-guided techniques in the placement of an internal jugular vein port in patients with advanced breast cancer. Methods: Between March 2010 and October 2010, 60 patients with advanced breast cancer underwent central venous port placement for the delivery of chemotherapy, preferably through the internal jugular vein. Patients were randomly assigned to either the anatomic-landmark or the ultrasound-guided group. Failure on first attempt, number of attempts until successful catheterization, time to successful placement, the accordance of the two placement approaches, and the demographics of each patient were recorded. Results: The consistency of the direction of two lines drawn using the anatomic-landmark and ultrasound-guided techniques or of the diameter of the internal jugular vein as determined by the two approaches was 85% (51/60). The rate of successful place- ment at first attempt was higher in the ultrasound group than in the anatomic-landmark group (P 〈 0.05). A greater number of attempts and longer time to successful port placement were needed in the latter (P 〈 0.05). Conclusion: The findings of this study indicate that, in the placement of an internal jugular vein port, the ultrasound (US)-guJded technique has several advantages over the anatomic-landmark technique.