According to the catastrophe model for impact buckling of static loading structures, a new catastrophe model for impact loading failure of a static loading rock system was established, and one dimension (1D) catastrop...According to the catastrophe model for impact buckling of static loading structures, a new catastrophe model for impact loading failure of a static loading rock system was established, and one dimension (1D) catastrophe model was analyzed. The analysis results indicate that the furcation collection where catastrophe may take place is not only decided by mechanical system itself but also relates to exterior loading, which is different from the results obtained under mono-static loading where the bifurcation collection is only determined by mechanics of the system itself and has nothing to do with exterior loading. In addition, the corresponding 1D coupled static-dynamic loading experiment is designed to verify the analysis results of catastrophe model. The test is done with Instron 1342 electro-servo controlled testing system, in which medium strain rate is caused by monotony rising dynamic load. The parameters are obtained combining theoretical model with experiment. The experimental and theoretical curves of critical dynamic load vs static load are rather coincided, thus the new model is proved to be correct.展开更多
Voltage profiles of feeders with the connection of distributed generations(DGs) were investigated.A unified typical load distribution model was established.Based on this model,exact expressions of feeder voltage profi...Voltage profiles of feeders with the connection of distributed generations(DGs) were investigated.A unified typical load distribution model was established.Based on this model,exact expressions of feeder voltage profile with single and double DGs were derived and used to analyze the impact of DG's location and capacity on the voltage profile quantitatively.Then,a general formula of the voltage profile was derived.The limitation of single DG and necessity of multiple DGs for voltage regulation were also discussed.Through the simulation,voltage profiles of feeders with single and double DGs were compared.The voltage excursion rate is 7.40% for only one DG,while 2.48% and 2.36% for double DGs.It is shown that the feeder voltage can be retained in a more appropriate range with multiple DGs than with only one DG.Distributing the total capacity of DGs is better than concentrating it at one point.展开更多
The validity of electric power system simulation or prediction models depends on static load model. Measurement- based approach is the unique method to identify them adequately. The measured power depends on both load...The validity of electric power system simulation or prediction models depends on static load model. Measurement- based approach is the unique method to identify them adequately. The measured power depends on both load reaction to supply voltage alteration and random process of load alteration Basically, there is no any universal method that can single out the inherent static load model from experimental data. The paper offers a proprietary technique which is the particular solution of the task. The technique considers the selection of neighboring measurement pairs with the supply voltage altering significantly be-tween them, the exclusion of selected pairs by load power factor and subsequent selection of the inherent static load model presented as the polynomial load model. The usage of the technique to identify static load model at “Fenster” industrial enterprise (in Borisov city) is presented. The ideas considered in the paper can be used for future development of static load model identification methods with the data obtained during both active experiment and in other operating models of electric power systems.展开更多
基金Project(50490272 ,50490274 ,10472134) supported by the Natural Science Foundation of China project(2005038250)supported by the China Postdoctoral Foundation
文摘According to the catastrophe model for impact buckling of static loading structures, a new catastrophe model for impact loading failure of a static loading rock system was established, and one dimension (1D) catastrophe model was analyzed. The analysis results indicate that the furcation collection where catastrophe may take place is not only decided by mechanical system itself but also relates to exterior loading, which is different from the results obtained under mono-static loading where the bifurcation collection is only determined by mechanics of the system itself and has nothing to do with exterior loading. In addition, the corresponding 1D coupled static-dynamic loading experiment is designed to verify the analysis results of catastrophe model. The test is done with Instron 1342 electro-servo controlled testing system, in which medium strain rate is caused by monotony rising dynamic load. The parameters are obtained combining theoretical model with experiment. The experimental and theoretical curves of critical dynamic load vs static load are rather coincided, thus the new model is proved to be correct.
基金Projects(60904101,60972164) supported by the National Natural Science Foundation of ChinaProject(N090404009) supported by the Fundamental Research Funds for the Central UniversitiesProject(20090461187) supported by China Postdoctoral Science Foundation
文摘Voltage profiles of feeders with the connection of distributed generations(DGs) were investigated.A unified typical load distribution model was established.Based on this model,exact expressions of feeder voltage profile with single and double DGs were derived and used to analyze the impact of DG's location and capacity on the voltage profile quantitatively.Then,a general formula of the voltage profile was derived.The limitation of single DG and necessity of multiple DGs for voltage regulation were also discussed.Through the simulation,voltage profiles of feeders with single and double DGs were compared.The voltage excursion rate is 7.40% for only one DG,while 2.48% and 2.36% for double DGs.It is shown that the feeder voltage can be retained in a more appropriate range with multiple DGs than with only one DG.Distributing the total capacity of DGs is better than concentrating it at one point.
文摘The validity of electric power system simulation or prediction models depends on static load model. Measurement- based approach is the unique method to identify them adequately. The measured power depends on both load reaction to supply voltage alteration and random process of load alteration Basically, there is no any universal method that can single out the inherent static load model from experimental data. The paper offers a proprietary technique which is the particular solution of the task. The technique considers the selection of neighboring measurement pairs with the supply voltage altering significantly be-tween them, the exclusion of selected pairs by load power factor and subsequent selection of the inherent static load model presented as the polynomial load model. The usage of the technique to identify static load model at “Fenster” industrial enterprise (in Borisov city) is presented. The ideas considered in the paper can be used for future development of static load model identification methods with the data obtained during both active experiment and in other operating models of electric power systems.