To promote the performance of the traditional multichannel filter bank which leads to speech quality degradation,an efficient design method of the non-uniform cosine modulated filter bank(CMFB) based on the audiogra...To promote the performance of the traditional multichannel filter bank which leads to speech quality degradation,an efficient design method of the non-uniform cosine modulated filter bank(CMFB) based on the audiogram for digital hearing aids is proposed. First, a low-pass prototype filter is designed by the linear iterative algorithm. Secondly,the uniform CMFB is achieved on the basis of the principle formulas. Then, the adjacent channels of a uniform filter bank which have low or gradual slopes are merged according to the trend of audiogram of the hearing impaired person. Finally,the corresponding non-uniform CMFB is obtained. Simulation results show that the signal processed by the proposed filter bank is similar to the original signal in a time-domain waveform and spectrogram without significant distortion or difference. The speech quality results show that the personal evaluation of speech quality(PESQ) of non-uniform CMFB is 35% higher than that of the traditional design, and the hearing-aid speech quality index(HASQI) increases by about 40%.展开更多
基金The National Natural Science Foundation of China(No.61375028,61673108)China Postdoctoral Science Foundation(No.2016M601696)+2 种基金Qing Lan Projectthe Program for Special Talent in Six Fields of Jiangsu Province(No.2016-DZXX-023)Jiangsu Planned Projects for Postdoctoral Research Funds(No.1601011B)
文摘To promote the performance of the traditional multichannel filter bank which leads to speech quality degradation,an efficient design method of the non-uniform cosine modulated filter bank(CMFB) based on the audiogram for digital hearing aids is proposed. First, a low-pass prototype filter is designed by the linear iterative algorithm. Secondly,the uniform CMFB is achieved on the basis of the principle formulas. Then, the adjacent channels of a uniform filter bank which have low or gradual slopes are merged according to the trend of audiogram of the hearing impaired person. Finally,the corresponding non-uniform CMFB is obtained. Simulation results show that the signal processed by the proposed filter bank is similar to the original signal in a time-domain waveform and spectrogram without significant distortion or difference. The speech quality results show that the personal evaluation of speech quality(PESQ) of non-uniform CMFB is 35% higher than that of the traditional design, and the hearing-aid speech quality index(HASQI) increases by about 40%.