通过考察电极长度及电极间距、检测管管径及材质、激励信号频率、电压和波形等参数对信噪比的影响,研制了一种适用于常规型离子色谱系统的电容耦合非接触式电导检测器(C^4D)。在抑制模式下,该检测器对常见无机阴离子(F^-、Cl^-、NO_2^-...通过考察电极长度及电极间距、检测管管径及材质、激励信号频率、电压和波形等参数对信噪比的影响,研制了一种适用于常规型离子色谱系统的电容耦合非接触式电导检测器(C^4D)。在抑制模式下,该检测器对常见无机阴离子(F^-、Cl^-、NO_2^-、Br^-、NO_3^-和SO_4^(2-))的检出限(信噪比=3)为0.02~0.08μmol/L;峰面积的相对标准偏差<1.8%(n=6);在0.1~10μm o l/L范围内上述6种无机阴离子线性关系良好,相关系数(R^2)>0.999。自制C4D的主要性能参数与商品化接触式电导检测器相当。该检测器具有结构简单、成本低廉、无电极污染等优点,有利于拓展离子色谱的应用范围。展开更多
A method based on capillary electrophoresis with a high frequency conductivity detection was developed for the determination of Sinomenine. The key factors for separation and determination were studied and the best an...A method based on capillary electrophoresis with a high frequency conductivity detection was developed for the determination of Sinomenine. The key factors for separation and determination were studied and the best analysis conditions were obtained. In the buffer of 2.0 mmol/L HAc-3.0 mmol/L NaAc-10.0% CH 3OH at a separation voltage of 22 kV, Sinomenine in the sample could be separated and detected within 4 min. The linear mass concentration of Sinomenine is in the range of 1.0—36.0 μg/mL, the limit of detection reached 0.20 μg/mL. The method was used for the analysis of Sinomenine in Sinomenium acutum and tablets satisfactorily with a recovery of 96%—102%.展开更多
A method based on capillary electrophoresis with a high frequency conductivity method was(developed) for the determination of eugenol in several Chinese herbal medicines from different producing areas.In this study,so...A method based on capillary electrophoresis with a high frequency conductivity method was(developed) for the determination of eugenol in several Chinese herbal medicines from different producing areas.In this study,some key factors for separation and detection were studied and the best analysis conditions were obtained.In the buffer system of 2.0 mmol/L triethylamine +0.74 mol/L methanol at separation potential of 18.0 kV,the optimal separation and detection was obtained.Under the chosen conditions,eugenol was eluted within 7 min.The linear range of eugenol was 2.0—540 μg/mL,the limit of detection was 0.6 μg/mL,and the recovery ranged from 93.3% to 106%.展开更多
文摘通过考察电极长度及电极间距、检测管管径及材质、激励信号频率、电压和波形等参数对信噪比的影响,研制了一种适用于常规型离子色谱系统的电容耦合非接触式电导检测器(C^4D)。在抑制模式下,该检测器对常见无机阴离子(F^-、Cl^-、NO_2^-、Br^-、NO_3^-和SO_4^(2-))的检出限(信噪比=3)为0.02~0.08μmol/L;峰面积的相对标准偏差<1.8%(n=6);在0.1~10μm o l/L范围内上述6种无机阴离子线性关系良好,相关系数(R^2)>0.999。自制C4D的主要性能参数与商品化接触式电导检测器相当。该检测器具有结构简单、成本低廉、无电极污染等优点,有利于拓展离子色谱的应用范围。
文摘A method based on capillary electrophoresis with a high frequency conductivity detection was developed for the determination of Sinomenine. The key factors for separation and determination were studied and the best analysis conditions were obtained. In the buffer of 2.0 mmol/L HAc-3.0 mmol/L NaAc-10.0% CH 3OH at a separation voltage of 22 kV, Sinomenine in the sample could be separated and detected within 4 min. The linear mass concentration of Sinomenine is in the range of 1.0—36.0 μg/mL, the limit of detection reached 0.20 μg/mL. The method was used for the analysis of Sinomenine in Sinomenium acutum and tablets satisfactorily with a recovery of 96%—102%.
文摘A method based on capillary electrophoresis with a high frequency conductivity method was(developed) for the determination of eugenol in several Chinese herbal medicines from different producing areas.In this study,some key factors for separation and detection were studied and the best analysis conditions were obtained.In the buffer system of 2.0 mmol/L triethylamine +0.74 mol/L methanol at separation potential of 18.0 kV,the optimal separation and detection was obtained.Under the chosen conditions,eugenol was eluted within 7 min.The linear range of eugenol was 2.0—540 μg/mL,the limit of detection was 0.6 μg/mL,and the recovery ranged from 93.3% to 106%.