AIM: To determine the value of bowel sounds analysis using an electronic stethoscope to support a clinical diagnosis of intestinal obstruction. METHODS: Subjects were patients who presented with a diagnosis of possibl...AIM: To determine the value of bowel sounds analysis using an electronic stethoscope to support a clinical diagnosis of intestinal obstruction. METHODS: Subjects were patients who presented with a diagnosis of possible intestinal obstruction based on symptoms, signs, and radiological findings. A 3MTH Littmann Model 4100 electronic stethoscope was used in this study. With the patients lying supine, six 8-second recordings of bowel sounds were taken from each patient from the lower abdomen. The recordings were analysed for sound duration, soundto-sound interval, dominant frequency, and peak frequency. Clinical and radiological data were reviewed and the patients were classified as having either acute, subacute, or no bowel obstruction. Comparison of bowel sound characteristics was made between these subgroups of patients. In the presence of an obstruction, the site of obstruction was identified and bowel calibre was also measured to correlate with bowel sounds. RESULTS: A total of 71 patients were studied during the period July 2009 to January 2011. Forty patientshad acute bowel obstruction (27 small bowel obstruction and 13 large bowel obstruction), 11 had subacute bowel obstruction (eight in the small bowel and three in large bowel) and 20 had no bowel obstruction (diagnoses of other conditions were made). Twenty-five patients received surgical intervention (35.2%) during the same admission for acute abdominal conditions. A total of 426 recordings were made and 420 recordings were used for analysis. There was no significant difference in sound-to-sound interval, dominant frequency, and peak frequency among patients with acute bowel obstruction, subacute bowel obstruction, and no bowel obstruction. In acute large bowel obstruction, the sound duration was significantly longer (median 0.81 s vs 0.55 s, P = 0.021) and the dominant frequency was significantly higher (median 440 Hz vs 288 Hz, P = 0.003) when compared to acute small bowel obstruction. No significant difference was seen between acute large bowel obstruction and large bowel pseudoobstruction. For patients with small bowel obstruction, the sound-to-sound interval was significantly longer in those who subsequently underwent surgery compared with those treated non-operatively (median 1.29 s vs 0.63 s, P < 0.001). There was no correlation between bowel calibre and bowel sound characteristics in both acute small bowel obstruction and acute large bowel obstruction. CONCLUSION: Auscultation of bowel sounds is nonspecific for diagnosing bowel obstruction. Differences in sound characteristics between large bowel and small bowel obstruction may help determine the likely site of obstruction.展开更多
This paper deals with internally generated noise of bioelectric amplifiers that are usually used for processing of bioelectric events. The main purpose of this paper is to present a procedure for analysis of the effec...This paper deals with internally generated noise of bioelectric amplifiers that are usually used for processing of bioelectric events. The main purpose of this paper is to present a procedure for analysis of the effects of internal noise generated by the active circuits and to evaluate the output noise of the author's new designed bioelectric amplifier that caused by internal effects to the amplifier circuit itself in order to compare it with the noise generated by conventional amplifiers. The obtained analysis results of internally generated noise showed that the total output noise of bioelectric active circuits does not increase when some of their resistors have a larger value. This behavior is caused by the different transfer functions for the signal and the respective noise sources associated with these resistors. Moreover, the new designed bioelectric amplifier has an output noise less than that for conventional amplifiers. The obtained analysis results were also experimentally verified and the final conclusions were drawn.展开更多
Previous studies have shown that reanalysis products contain large uncertainties in the Tibetan Plateau(TP),and the biases are location dependent.Therefore,these products must be evaluated with in situ observations pr...Previous studies have shown that reanalysis products contain large uncertainties in the Tibetan Plateau(TP),and the biases are location dependent.Therefore,these products must be evaluated with in situ observations prior to their applications.In this study,the authors compare the results of several reanalysis projects with independent sounding observations recorded in the Yarlung Tsangpo River valley in the Eastern Himalayas in June 2010.These reanalysis projects include Climate Forecast System Reanalysis(CFSR),Interim European Centre for Medium Range Weather Forecasts Reanalysis(ERA- Interim),Japanese 25-year Reanalysis(JRA-25),Modern Era Retrospective Analysis for Research and Applications(MERRA),National Center for Environmental Prediction and the Department of Energy Reanalysis 2(NCEP-R2),and NCEP Final Analysis(FNL).Statistical quantities such as average,mean bias(MB),root-mean-square difference(RMSD),and correlation coefficient(R) of temperature,specific humidity,u-wind,and v-wind between 100 hPa and 650 hPa were calculated.The authors determined that the performance of each product differed with variables at different levels.The average profiles of the variables were captured by the reanalysis products,with large biases appearing at lower levels.ERA-Interim and NCEP-R2 showed the best and worst performances,respectively,for all variables.This study suggests that users should select appropriate reanalysis products according to their specific purposes for TP research.展开更多
A novel algorithm for voice conversion is proposed in this paper. The mapping function of spectral vectors of the source and target speakers is calculated by the Canonical Correlation Analysis (CCA) estimation based o...A novel algorithm for voice conversion is proposed in this paper. The mapping function of spectral vectors of the source and target speakers is calculated by the Canonical Correlation Analysis (CCA) estimation based on Gaussian mixture models. Since the spectral envelope feature remains a majority of second order statistical information contained in speech after Linear Prediction Coding (LPC) analysis, the CCA method is more suitable for spectral conversion than Minimum Mean Square Error (MMSE) because CCA explicitly considers the variance of each component of the spectral vectors during conversion procedure. Both objective evaluations and subjective listening tests are conducted. The experimental results demonstrate that the proposed scheme can achieve better per- formance than the previous method which uses MMSE estimation criterion.展开更多
High efficiency audio compression is the basic technology in audio involved multimedia communications. Downmixing and parametric coding is efficient coding scheme with wide applications in some up-to-date audio codecs...High efficiency audio compression is the basic technology in audio involved multimedia communications. Downmixing and parametric coding is efficient coding scheme with wide applications in some up-to-date audio codecs such as Parametric Stereo (PS) in EAAC+ and MPEG-Surround. Principle Component Analysis (PCA) stereo coding followed this idea to map two channels to one channel with maximum energy and parameterize the secondary channel. This paper investigates the conventional PCA method performance under general stereo model with multiple sound sources and different directions, and then proposes a Polar Coordinate based PCA (PC-PCA) stereo coding method. It has been proved that when multiple sound sources exist with different directions, PC-PCA is better than the conventional PCA method when Mean to Standard deviation Ratio (MSR) is large. A stereo codec based on PC-PCA is proposed to validate the performance improvement of proposed method. Objective and subjective tests show the proposed method achieves a comparative quality and saves 50% parameter bit rate comparing with conventional PCA method, and obtains a 4-8 MUSHRA scores improvement comparing with state-of-the-art stereo codec at the same parameter bit rate.展开更多
This study investigated how background speech affected L1 and L2 reading of Chinese English major students. English, Dutch, and Mandarin Chinese were respectively set as the second language (L2), foreign language ...This study investigated how background speech affected L1 and L2 reading of Chinese English major students. English, Dutch, and Mandarin Chinese were respectively set as the second language (L2), foreign language (FL), and first language (L1) background speech conditions. Self-paced word-by-word reading paradigm was used to collect the response time (RT) of each word. The conventional analysis revealed that L1 background speech exerted the most disruptive effect on both L1 and L2 reading could be phonological and could be at the and suggested that the background speech effect stage of phonological processing of L1 and L2 reading. It also implied that L1 phonological processing could be simultaneously activated during L2 reading. Spectral analysis of ten subjects' reading data indicated that pink noise existed in each time series of word RT of L1 and L2 reading in each condition. It provided clear evidence that L1 and L2 reading processing are similar with different concurrent background speech.展开更多
Motivated by a phenomenon in an experiment conducted in the Northwestern Pacific indicating that the energy of the received signal around the sound channel axis is much greater than that at shallower depths,we study s...Motivated by a phenomenon in an experiment conducted in the Northwestern Pacific indicating that the energy of the received signal around the sound channel axis is much greater than that at shallower depths,we study sound propagation from the transitional area(shelfbreak)to deep water.Numerical simulations with different source depths are first performed,from which we reach the following conclusions.When the source is located near the sea surface,sound will be strongly attenuated by bottom losses in a range-independent oceanic environment,whereas it can propagate to a very long range because of the continental slope.When the source is mounted on the bottom in shallow water,acoustic energy will be trapped near the sound channel axis,and it converges more evidently than the case where the source is located near the sea surface.Then,numerical simulations with different source ranges are performed.By comparing the relative energy level in the vertical direction between the numerical simulations and the experimental data,the range of the air-gun source can be approximated.展开更多
文摘AIM: To determine the value of bowel sounds analysis using an electronic stethoscope to support a clinical diagnosis of intestinal obstruction. METHODS: Subjects were patients who presented with a diagnosis of possible intestinal obstruction based on symptoms, signs, and radiological findings. A 3MTH Littmann Model 4100 electronic stethoscope was used in this study. With the patients lying supine, six 8-second recordings of bowel sounds were taken from each patient from the lower abdomen. The recordings were analysed for sound duration, soundto-sound interval, dominant frequency, and peak frequency. Clinical and radiological data were reviewed and the patients were classified as having either acute, subacute, or no bowel obstruction. Comparison of bowel sound characteristics was made between these subgroups of patients. In the presence of an obstruction, the site of obstruction was identified and bowel calibre was also measured to correlate with bowel sounds. RESULTS: A total of 71 patients were studied during the period July 2009 to January 2011. Forty patientshad acute bowel obstruction (27 small bowel obstruction and 13 large bowel obstruction), 11 had subacute bowel obstruction (eight in the small bowel and three in large bowel) and 20 had no bowel obstruction (diagnoses of other conditions were made). Twenty-five patients received surgical intervention (35.2%) during the same admission for acute abdominal conditions. A total of 426 recordings were made and 420 recordings were used for analysis. There was no significant difference in sound-to-sound interval, dominant frequency, and peak frequency among patients with acute bowel obstruction, subacute bowel obstruction, and no bowel obstruction. In acute large bowel obstruction, the sound duration was significantly longer (median 0.81 s vs 0.55 s, P = 0.021) and the dominant frequency was significantly higher (median 440 Hz vs 288 Hz, P = 0.003) when compared to acute small bowel obstruction. No significant difference was seen between acute large bowel obstruction and large bowel pseudoobstruction. For patients with small bowel obstruction, the sound-to-sound interval was significantly longer in those who subsequently underwent surgery compared with those treated non-operatively (median 1.29 s vs 0.63 s, P < 0.001). There was no correlation between bowel calibre and bowel sound characteristics in both acute small bowel obstruction and acute large bowel obstruction. CONCLUSION: Auscultation of bowel sounds is nonspecific for diagnosing bowel obstruction. Differences in sound characteristics between large bowel and small bowel obstruction may help determine the likely site of obstruction.
文摘This paper deals with internally generated noise of bioelectric amplifiers that are usually used for processing of bioelectric events. The main purpose of this paper is to present a procedure for analysis of the effects of internal noise generated by the active circuits and to evaluate the output noise of the author's new designed bioelectric amplifier that caused by internal effects to the amplifier circuit itself in order to compare it with the noise generated by conventional amplifiers. The obtained analysis results of internally generated noise showed that the total output noise of bioelectric active circuits does not increase when some of their resistors have a larger value. This behavior is caused by the different transfer functions for the signal and the respective noise sources associated with these resistors. Moreover, the new designed bioelectric amplifier has an output noise less than that for conventional amplifiers. The obtained analysis results were also experimentally verified and the final conclusions were drawn.
基金supported by the Special Fund for Meteorological Research in the Public Interest (GYHY2012 06041)the National Natural Science Foundation of China (Grant No.40905067)and the Ministry of Science and Technology of the People’s Republic of China (2009CB421403)
文摘Previous studies have shown that reanalysis products contain large uncertainties in the Tibetan Plateau(TP),and the biases are location dependent.Therefore,these products must be evaluated with in situ observations prior to their applications.In this study,the authors compare the results of several reanalysis projects with independent sounding observations recorded in the Yarlung Tsangpo River valley in the Eastern Himalayas in June 2010.These reanalysis projects include Climate Forecast System Reanalysis(CFSR),Interim European Centre for Medium Range Weather Forecasts Reanalysis(ERA- Interim),Japanese 25-year Reanalysis(JRA-25),Modern Era Retrospective Analysis for Research and Applications(MERRA),National Center for Environmental Prediction and the Department of Energy Reanalysis 2(NCEP-R2),and NCEP Final Analysis(FNL).Statistical quantities such as average,mean bias(MB),root-mean-square difference(RMSD),and correlation coefficient(R) of temperature,specific humidity,u-wind,and v-wind between 100 hPa and 650 hPa were calculated.The authors determined that the performance of each product differed with variables at different levels.The average profiles of the variables were captured by the reanalysis products,with large biases appearing at lower levels.ERA-Interim and NCEP-R2 showed the best and worst performances,respectively,for all variables.This study suggests that users should select appropriate reanalysis products according to their specific purposes for TP research.
文摘A novel algorithm for voice conversion is proposed in this paper. The mapping function of spectral vectors of the source and target speakers is calculated by the Canonical Correlation Analysis (CCA) estimation based on Gaussian mixture models. Since the spectral envelope feature remains a majority of second order statistical information contained in speech after Linear Prediction Coding (LPC) analysis, the CCA method is more suitable for spectral conversion than Minimum Mean Square Error (MMSE) because CCA explicitly considers the variance of each component of the spectral vectors during conversion procedure. Both objective evaluations and subjective listening tests are conducted. The experimental results demonstrate that the proposed scheme can achieve better per- formance than the previous method which uses MMSE estimation criterion.
基金supported by National Natural Science Foundation of China under Grants No. 61231015, No. 61102127 No. 61201340, No. 61201169Major National Science and Technology Special Projects under Grant No. 2010ZX03004-003-03+2 种基金Natural Science Foundation of Hubei Province under Grant No. 2011CDB451Wuhan ChenGuang Science and Technology Plan under Grant No. 201150431104the Fundamental Research Funds for the Central Universities
文摘High efficiency audio compression is the basic technology in audio involved multimedia communications. Downmixing and parametric coding is efficient coding scheme with wide applications in some up-to-date audio codecs such as Parametric Stereo (PS) in EAAC+ and MPEG-Surround. Principle Component Analysis (PCA) stereo coding followed this idea to map two channels to one channel with maximum energy and parameterize the secondary channel. This paper investigates the conventional PCA method performance under general stereo model with multiple sound sources and different directions, and then proposes a Polar Coordinate based PCA (PC-PCA) stereo coding method. It has been proved that when multiple sound sources exist with different directions, PC-PCA is better than the conventional PCA method when Mean to Standard deviation Ratio (MSR) is large. A stereo codec based on PC-PCA is proposed to validate the performance improvement of proposed method. Objective and subjective tests show the proposed method achieves a comparative quality and saves 50% parameter bit rate comparing with conventional PCA method, and obtains a 4-8 MUSHRA scores improvement comparing with state-of-the-art stereo codec at the same parameter bit rate.
文摘This study investigated how background speech affected L1 and L2 reading of Chinese English major students. English, Dutch, and Mandarin Chinese were respectively set as the second language (L2), foreign language (FL), and first language (L1) background speech conditions. Self-paced word-by-word reading paradigm was used to collect the response time (RT) of each word. The conventional analysis revealed that L1 background speech exerted the most disruptive effect on both L1 and L2 reading could be phonological and could be at the and suggested that the background speech effect stage of phonological processing of L1 and L2 reading. It also implied that L1 phonological processing could be simultaneously activated during L2 reading. Spectral analysis of ten subjects' reading data indicated that pink noise existed in each time series of word RT of L1 and L2 reading in each condition. It provided clear evidence that L1 and L2 reading processing are similar with different concurrent background speech.
基金supported by the National Natural Science Foundation of China(Grant No.11125420)
文摘Motivated by a phenomenon in an experiment conducted in the Northwestern Pacific indicating that the energy of the received signal around the sound channel axis is much greater than that at shallower depths,we study sound propagation from the transitional area(shelfbreak)to deep water.Numerical simulations with different source depths are first performed,from which we reach the following conclusions.When the source is located near the sea surface,sound will be strongly attenuated by bottom losses in a range-independent oceanic environment,whereas it can propagate to a very long range because of the continental slope.When the source is mounted on the bottom in shallow water,acoustic energy will be trapped near the sound channel axis,and it converges more evidently than the case where the source is located near the sea surface.Then,numerical simulations with different source ranges are performed.By comparing the relative energy level in the vertical direction between the numerical simulations and the experimental data,the range of the air-gun source can be approximated.