The supersonic nozzle is the most important device of an ejector-diffuser system.The best operation condition and optimal structure of supersonic nozzle are hardly known due to the complicated turbulent mixing,compres...The supersonic nozzle is the most important device of an ejector-diffuser system.The best operation condition and optimal structure of supersonic nozzle are hardly known due to the complicated turbulent mixing,compressibility effects and even flow unsteadiness which are generated around the nozzle extent.In the present study,the primary stream nozzle was redesigned using convergent nozzle to activate the shear actions between the primary and secondary streams,by means of longitudinal vortices generated between the Chevron lobes.Exactly same geometrical model of ejector-diffuser system was created to validate the results of experimental data.The operation characteristics of the ejector system were compared between Chevron nozzle and conventional convergent nozzle for the primary stream.A CFD method has been applied to simulate the supersonic flows and shock waves inside the ejector.It is observed that the flow structure and shock system were changed and primary numerical analysis results show that the Chevron nozzle achieve a positive effect on the supersonic ejector-diffuser system performance.The ejector with Chevron nozzle can entrain more secondary stream with less primary stream mass flow rate.展开更多
Different systems have been used over the years to deliver drug particles to the human skin for pharmaceutical effect. Research has been done to improve the performance and flexibility of these systems. In recent year...Different systems have been used over the years to deliver drug particles to the human skin for pharmaceutical effect. Research has been done to improve the performance and flexibility of these systems. In recent years a unique system called the transdermal drug delivery has been developed. Transdermal drug delivery opened a new door in the field of drug delivery as it is more flexible and offers better performance than the conventional systems. The principle of this system is to accelerate drug particles with a high speed gas flow. Among different transdermal drug delivery systems we will concentrate on the contour shock tube system in this paper. A contoured shock tube is consists of a rupture chamber, a shock tube and a supersonic nozzle section. The drug particles are retained between a set of bursting diaphragm. When the diaphragm is ruptured at a certain pressure, a high speed unsteady flow is initiated through the shock tube which accelerates the particles. Computational fluid dynamics is used to simulate and analyze the flow field. The DPM (discrete phase method) is used to model the particle flow. As an unsteady flow is initiated though the shock tube the drag correlation proposed by Igra et al is used other than the standard drag correlation. The particle velocities at different sections including the nozzle exit are investigated under different operating conditions. Static pressure histories in different sections in the shock tube are investigated to analyze the flow field. The important aspects of the gas and particle dynamics in the shock tube are discussed and analyzed in details.展开更多
文摘The supersonic nozzle is the most important device of an ejector-diffuser system.The best operation condition and optimal structure of supersonic nozzle are hardly known due to the complicated turbulent mixing,compressibility effects and even flow unsteadiness which are generated around the nozzle extent.In the present study,the primary stream nozzle was redesigned using convergent nozzle to activate the shear actions between the primary and secondary streams,by means of longitudinal vortices generated between the Chevron lobes.Exactly same geometrical model of ejector-diffuser system was created to validate the results of experimental data.The operation characteristics of the ejector system were compared between Chevron nozzle and conventional convergent nozzle for the primary stream.A CFD method has been applied to simulate the supersonic flows and shock waves inside the ejector.It is observed that the flow structure and shock system were changed and primary numerical analysis results show that the Chevron nozzle achieve a positive effect on the supersonic ejector-diffuser system performance.The ejector with Chevron nozzle can entrain more secondary stream with less primary stream mass flow rate.
基金supported by the National Research Foundation of Korea (NRF) grant funded by the Korea government (MEST) (2011-0017506)
文摘Different systems have been used over the years to deliver drug particles to the human skin for pharmaceutical effect. Research has been done to improve the performance and flexibility of these systems. In recent years a unique system called the transdermal drug delivery has been developed. Transdermal drug delivery opened a new door in the field of drug delivery as it is more flexible and offers better performance than the conventional systems. The principle of this system is to accelerate drug particles with a high speed gas flow. Among different transdermal drug delivery systems we will concentrate on the contour shock tube system in this paper. A contoured shock tube is consists of a rupture chamber, a shock tube and a supersonic nozzle section. The drug particles are retained between a set of bursting diaphragm. When the diaphragm is ruptured at a certain pressure, a high speed unsteady flow is initiated through the shock tube which accelerates the particles. Computational fluid dynamics is used to simulate and analyze the flow field. The DPM (discrete phase method) is used to model the particle flow. As an unsteady flow is initiated though the shock tube the drag correlation proposed by Igra et al is used other than the standard drag correlation. The particle velocities at different sections including the nozzle exit are investigated under different operating conditions. Static pressure histories in different sections in the shock tube are investigated to analyze the flow field. The important aspects of the gas and particle dynamics in the shock tube are discussed and analyzed in details.