RH喷吹参数对循环流量和均混时间影响的物理模拟 被引量:6
1
作者 郑万 贺志鹏 +2 位作者 李光强 屠浩 张战 《钢铁研究学报》 CAS CSCD 北大核心 2017年第5期373-381,共9页
以某厂300tRH真空精炼装置为研究原型,建立1∶6.5的水力模型对RH喷吹精炼工艺进行物理模拟。研究了喷吹位置、喷吹气量及驱动气体流量对循环流量和均混时间的影响。结果表明:不同喷吹气量、驱动气体流量条件下,获得大循环流量和短均混... 以某厂300tRH真空精炼装置为研究原型,建立1∶6.5的水力模型对RH喷吹精炼工艺进行物理模拟。研究了喷吹位置、喷吹气量及驱动气体流量对循环流量和均混时间的影响。结果表明:不同喷吹气量、驱动气体流量条件下,获得大循环流量和短均混时间的最优喷吹位置不同。较小的喷吹气量(2.98~3.53m3/h)或者较小的驱动气体流量(0.93~1.02m3/h)时,宜采用低顶枪枪位(153.8mm)喷吹;喷吹气量大于3.91m3/h或者驱动气体流量大于1.12m3/h时,宜采用真空槽底部喷吹角度120°的侧喷嘴喷吹。顶枪与侧喷嘴复合喷吹有利于提高RH喷吹工艺的适应性及循环效率。 展开更多
关键词 RH真空精炼 顶枪喷吹 均混时间 循环流量 物理模拟
原文传递
Mathematical Model Prediction of Heat Losses from a Pilot Sirosmelt Furnace
2
作者 Yuhua Pan Michael A. Somerville 《Journal of Mechanics Engineering and Automation》 2015年第9期487-496,共10页
A mathematical model was developed for simulating heat transfer through the sidewall, bottom and top of a pilot scale TSL (Top-Submerged-Lance) Sirosmelt furnace. With a feed rate of about 50 kg/h, the furnace has b... A mathematical model was developed for simulating heat transfer through the sidewall, bottom and top of a pilot scale TSL (Top-Submerged-Lance) Sirosmelt furnace. With a feed rate of about 50 kg/h, the furnace has been used for investigating the technical feasibility of a variety of pyrometallurgical processes for smelting nonferrous and ferrous metals and for high temperature processing of solid wastes including electronic scraps, etc. The model was based on numerical solution of energy transport equations governing heat conduction in multi-layered linings in the sidewall, bottom and top lid of the furnace as well as convection and radiation of heat from the furnace outer surfaces to the ambient. Imperfect contacts between two neighboring solid lining layers due to air gap formation were considered. Temperature profiles were determined across the furnace bottom, top lid and three sections of the furnace sidewall, from which the heat loss rates through the corresponding parts of the furnace were calculated. The modelling results indicate that approximately 88% of heat is lost from the furnace sidewall, 7-8% from the bottom and 4-5% from the top lid. With increasing melt bath temperature, the proportion of total heat loss from the bottom decreases whereas that from the top lid increases and that from the sidewall is little changed. For a bath temperature of 1,300℃, total absolute heat loss rate from the furnace was found to be close to 12 kW. 展开更多
关键词 Heat transfer heat loss TSL SMELTING MODELLING simulation.
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部