Inter-domain path computing is one big issue in multi-domain networks. The Hierarchical Path Computing Element (H-PCE) is a semi-central architecture for computing inter-domain path. To facilitate H-PCE in inter-domai...Inter-domain path computing is one big issue in multi-domain networks. The Hierarchical Path Computing Element (H-PCE) is a semi-central architecture for computing inter-domain path. To facilitate H-PCE in inter-domain path computing, this paper proposed a topology aggregation scheme to abstract the edge nodes and their connected inter-domain link as one vertex to achieve more optimal paths and confidentiality guarantee. The effectiveness of the scheme has been demonstrated on solving wavelength routing in multi-domain Wavelength Division Multiplexing (WDM) network via simulation. Simulation results show that this scheme reduces at least 10% inter-domain blocking probability, compared with the traditional Domain-to-the-Node (DtN) scheme.展开更多
As a result of the left-lateral strike-slipping of the Altyn Tagh fault in Neotectonic period, a contra-rotational structure, namely the Zhaobishan vortex structure, has developed at the juncture of the main Altyn Tag...As a result of the left-lateral strike-slipping of the Altyn Tagh fault in Neotectonic period, a contra-rotational structure, namely the Zhaobishan vortex structure, has developed at the juncture of the main Altyn Tagh fault and the northern fringe fault of the Qilian Mountains. Preliminary analysis on the deformation and evolution of the Zhaobishan vortex structure. In combination with the previous data, suggests that the tectonic transform between the Altyn Tagh fault and the northern fringe fault of the Qilian Mountains attributes to the deformation of the rotational structure. The existence of a series of rotational structures along the Altyn Tagh fault and on the northeastern edge of the Qinghai-Xizang(Tibet) plateau indicate that as the substance in the northern Qinghai-Xizang (Tibet) plateau moves clockwise around the eastern tectonic knot of the Himalayas, rotational structures become the principal mode on the northern marginal zone of the Plateau of transforming and absorbing tectonic deformation.展开更多
This paper analyzes the effects of the voltage across insulator of 69 kV and 24 kV lines installed on the same pole. The case studies illustrated the lightning strike to direct top pole and mid span of ground wire usi...This paper analyzes the effects of the voltage across insulator of 69 kV and 24 kV lines installed on the same pole. The case studies illustrated the lightning strike to direct top pole and mid span of ground wire using the ATP-EMTP (Alternative Transient Program-Electromagnetic Transient Program). The results found that when lightning strike the voltage across the 69 kV line insulator at mid span is 1.55 times and 1.34 times higher than at top pole when the front time is 0.25/100μs and 10/350 μs, respectively. When lightning strike the voltage across the 24 kV line at mid span is 1.04 times and 0.64 times higher than at top pole when the front time is 0.25/100μs and 10/350μs, respectively. So the effect of lightning strike is more severe at mid span than at the direct top pole, especially for the 69 kV insulator.展开更多
基金Acknowledgements This work was supported by Chang Jiang Scholars Program of the Ministry of Education of China, National Science Fund for Distinguished Young Scholars under Grant No.60725104 the National Basic Research Program of China under Grant No. 2007CB310706+2 种基金 the National Natural Science Foundation of China under Ca'ant No. 60932002, No. 60932005, No. 61071101 the Hi-Tech Research and Development Program of China under Grant No. 2009AA01Z254, No. 2009AA01Z215 NCEF Program of MoE of China, and Sichuan Youth Science and Technology Foundation under Crant No. 09ZQ026-032.
文摘Inter-domain path computing is one big issue in multi-domain networks. The Hierarchical Path Computing Element (H-PCE) is a semi-central architecture for computing inter-domain path. To facilitate H-PCE in inter-domain path computing, this paper proposed a topology aggregation scheme to abstract the edge nodes and their connected inter-domain link as one vertex to achieve more optimal paths and confidentiality guarantee. The effectiveness of the scheme has been demonstrated on solving wavelength routing in multi-domain Wavelength Division Multiplexing (WDM) network via simulation. Simulation results show that this scheme reduces at least 10% inter-domain blocking probability, compared with the traditional Domain-to-the-Node (DtN) scheme.
文摘As a result of the left-lateral strike-slipping of the Altyn Tagh fault in Neotectonic period, a contra-rotational structure, namely the Zhaobishan vortex structure, has developed at the juncture of the main Altyn Tagh fault and the northern fringe fault of the Qilian Mountains. Preliminary analysis on the deformation and evolution of the Zhaobishan vortex structure. In combination with the previous data, suggests that the tectonic transform between the Altyn Tagh fault and the northern fringe fault of the Qilian Mountains attributes to the deformation of the rotational structure. The existence of a series of rotational structures along the Altyn Tagh fault and on the northeastern edge of the Qinghai-Xizang(Tibet) plateau indicate that as the substance in the northern Qinghai-Xizang (Tibet) plateau moves clockwise around the eastern tectonic knot of the Himalayas, rotational structures become the principal mode on the northern marginal zone of the Plateau of transforming and absorbing tectonic deformation.
文摘This paper analyzes the effects of the voltage across insulator of 69 kV and 24 kV lines installed on the same pole. The case studies illustrated the lightning strike to direct top pole and mid span of ground wire using the ATP-EMTP (Alternative Transient Program-Electromagnetic Transient Program). The results found that when lightning strike the voltage across the 69 kV line insulator at mid span is 1.55 times and 1.34 times higher than at top pole when the front time is 0.25/100μs and 10/350 μs, respectively. When lightning strike the voltage across the 24 kV line at mid span is 1.04 times and 0.64 times higher than at top pole when the front time is 0.25/100μs and 10/350μs, respectively. So the effect of lightning strike is more severe at mid span than at the direct top pole, especially for the 69 kV insulator.