菱形磁介质参数对磁场特性的影响 被引量:2
1
作者 张涛 李茂林 +2 位作者 胡伟 姚伟 彭兴华 《金属矿山》 CAS 北大核心 2016年第4期110-113,共4页
为考察菱形磁介质表面的磁场特性随其顶角α的变化趋势,采用ANSYS软件模拟了不同顶角角度下的菱形磁介质在不同背景磁感应强度下的磁场特性。结果表明:背景磁感应强度为0.2 T时,菱形聚磁介质表面产生的磁场强度、磁场梯度和磁场力均随... 为考察菱形磁介质表面的磁场特性随其顶角α的变化趋势,采用ANSYS软件模拟了不同顶角角度下的菱形磁介质在不同背景磁感应强度下的磁场特性。结果表明:背景磁感应强度为0.2 T时,菱形聚磁介质表面产生的磁场强度、磁场梯度和磁场力均随α的增加而降低;背景磁感应强度大于0.2 T时,菱形磁介质表面产生的磁场强度、磁场梯度和磁场力均随α的增加呈先提高后降低的趋势,并且在达到极值前随α的增加缓慢提高,达到极值后随α的增加快速降低。磁介质顶角α增加使得介质有效迎磁面积增大,这有利于提高介质的聚磁能力,表现为磁场强度、磁场梯度和磁场力的提高,但有效迎磁面积太大会使磁力线分布更为分散,导致磁场强度、磁场梯度和磁场力的降低。在低背景磁感应强度下,聚磁能力始终小于分散磁场力的作用,表现为磁场强度、磁场梯度、磁场力随介质顶角的增加先缓慢下降后快速下降;在高背景磁场强度下,α小于某角度时,聚磁作用大于分散磁场力作用,α大于这个角度时,聚磁作用小于分散磁场力作用,表现为磁场强度、磁场梯度、磁场力随介质顶角的增加先缓慢提高后快速下降。 展开更多
关键词 菱形磁介质 顶角角度 磁场强度 磁场梯度 磁场力 有效迎磁面积
下载PDF
Effects of corneal thickness distribution and apex position on postoperative refractive status after full-bed deep anterior lamellar keratoplasty
2
作者 Bing-hong WANG Ye-sheng XU +1 位作者 Wen-jia XIE Yu-feng YAO 《Journal of Zhejiang University-Science B(Biomedicine & Biotechnology)》 SCIE CAS CSCD 2018年第11期863-870,共8页
Objective: To investigate the effects of corneal thickness distribution and apex position on postoperative refractive status after full-bed deep anterior lamellar keratoplasty (FBDALK). Methods: This is a retrospe... Objective: To investigate the effects of corneal thickness distribution and apex position on postoperative refractive status after full-bed deep anterior lamellar keratoplasty (FBDALK). Methods: This is a retrospective analysis of patients who were diagnosed with advanced keratoconus between 2011 and 2014 in our hospital. The base of the cone in all patients did not exceed the central cornea at a 6-mm range. The FBDALK was performed by a same surgeon. All patients had a complete corneal suture removal and the follow-up records were intact. Patients who had graft-bed misalignment or who were complicated with a cataract or glaucoma were excluded. Uncorrected visual acuity (UCVA), best spectacle corrected visual acuity (BSCVA), and Pentacam examination data were recorded at two years postoperatively. The recorded data included the superior-inferior (S-I) and nasal-temporal (N-T) corneal thickness differences in 2, 4, 6, and 8 mm diameter concentric circles with the corneal apex as the center (S-I2 mm, S-14 mm, S-I6mm,, S-I8mm, N-T2mm, N-T4 mm, N-T6 mm, and N-T8 mm), the linear, X-axis, and Y-axis distance between the corneal pupillary center and the cornea apex, total corneal astigmatism at a zone of 3 mm diameter from the corneal apex (TA3 mm), the astigmatic vector values J0 and J4s, and the corneal total higher-order aberration for 3 and 6 mm pupil diameters (HOA3 mm and HOA6mm). Statistical analysis was performed by SPSS 15.0. Results: A total of 47 eyes of 46 patients met the criteria and were included in this study. The mean follow-up time was (28±7) months. The mean UCVA was 0.45±0.23 (IogMAR) (MAR: minimum angle of resolution) and the mean BSCVA was 0.19±0.15 (IogMAR), which were all sig- nificantly positively correlated with postoperative TA3 mm and HOA3 turn. The mean S-I corneal thickness differences were (44.62±37.74) IJm, and the mean N-T was (38.57±32.29) pm. S-12 mm was significantly positively correlated with J0 (r=0.31), J45 (r=0.42), HOA3 mm (r=0.37), and HOA6 mm (r=0.48). S-14 mm and S-Is mm were significantly positively corre- lated with HOA3 mm (t=0.30, t=0.40) and HOA6 mm (r=0.46, r=0.35). The X-axis distance between corneal pupillary center and corneal apex was significantly positively correlated with J45 (r=0.29). Conclusions: In patients with ad- vanced keratoconus after FBDALK, the unevenly distributed thickness at corneal pupillary area and the misalignment of corneal apex and pupillary center might cause significant regular and irregular astigmatism, which affected the postoperative visual quality. 展开更多
关键词 Full-bed deep anterior lamellar keratoplasty Corneal thickness distribution Corneal apex