To control complex system's safety effectively,safety control program was supported based on the principles of behavioral science that shapes organizational be- havior,and organizational behavior produced individu...To control complex system's safety effectively,safety control program was supported based on the principles of behavioral science that shapes organizational be- havior,and organizational behavior produced individual behavior.The program can be structured into a model that consists of three modules including individual behavior rectifi- cation,organization behavior diagnosis and model of safety culture.The research result not only reveals the deep cause of complex system accidents but also provides structural descriptions with the accidents cause.展开更多
Nowadays, PD (partial discharge) measurements are a crucial part of the preventive maintenance of electrical equipment within high voltage engineering. Especially for electrical machines, both the supplier and the u...Nowadays, PD (partial discharge) measurements are a crucial part of the preventive maintenance of electrical equipment within high voltage engineering. Especially for electrical machines, both the supplier and the user are interested in the results of PD measurements. However, PDs hardly represent the cause of the failure, more likely they are claimed as the outcome of a failure. This paper deals with the insulation of a 6 kV electrical machine, whereas PD measurements were carried out at a single stator from wound coils. During manufacturing, these coils were equipped with different materials for the OCP (outer corona protection). Using different PD measurement systems and different bandwidths, investigations of the PD behavior of the coils were carried out. Additionally, the surface resistivity of the corona protection was determined. As a result, conclusions for the correlations between the resistance of the OCP as well as the PD behavior are stated. Furthermore, the influence of using different measurement systems, different measuring circuits, and different bandwidths is shown.展开更多
文摘To control complex system's safety effectively,safety control program was supported based on the principles of behavioral science that shapes organizational be- havior,and organizational behavior produced individual behavior.The program can be structured into a model that consists of three modules including individual behavior rectifi- cation,organization behavior diagnosis and model of safety culture.The research result not only reveals the deep cause of complex system accidents but also provides structural descriptions with the accidents cause.
文摘Nowadays, PD (partial discharge) measurements are a crucial part of the preventive maintenance of electrical equipment within high voltage engineering. Especially for electrical machines, both the supplier and the user are interested in the results of PD measurements. However, PDs hardly represent the cause of the failure, more likely they are claimed as the outcome of a failure. This paper deals with the insulation of a 6 kV electrical machine, whereas PD measurements were carried out at a single stator from wound coils. During manufacturing, these coils were equipped with different materials for the OCP (outer corona protection). Using different PD measurement systems and different bandwidths, investigations of the PD behavior of the coils were carried out. Additionally, the surface resistivity of the corona protection was determined. As a result, conclusions for the correlations between the resistance of the OCP as well as the PD behavior are stated. Furthermore, the influence of using different measurement systems, different measuring circuits, and different bandwidths is shown.