期刊文献+
共找到5篇文章
< 1 >
每页显示 20 50 100
HARRIS DX-100数字调幅中波广播发射机预驱动器故障检修 被引量:2
1
作者 袁桂芳 王廷富 《西部广播电视》 2012年第12期74-76,共3页
本文简述了HARRIS DX-100中波数字调幅广播发射机预驱器的原理及故障实例的分析处理。
关键词 中波发射机 预驱动器 射频封锁 取样电路
下载PDF
TSD-100 DAM中波广播发射机“中放”故障分析与处理
2
作者 简永蔓 王廷富 《西部广播电视》 2015年第18期221-221,230,共2页
本文介绍上海明珠TSD-100中波广播发射机中放原理及故障分析处理和维护体会
关键词 中放 预驱动器 前置驱动 比较器 开机请求
下载PDF
Realization of a tunable analog predistorter using parallel combination technique for laser driver applications
3
作者 宋奇伟 Mao Luhong +1 位作者 Xie Sheng Zhang Shilin 《High Technology Letters》 EI CAS 2015年第1期90-95,共6页
This paper describes a new approach for designing analog predistorters that can compensate for the nonlinear distortion of laser drivers in a radio-over-fiber (RoF) system. In contrast to previous works, this paper ... This paper describes a new approach for designing analog predistorters that can compensate for the nonlinear distortion of laser drivers in a radio-over-fiber (RoF) system. In contrast to previous works, this paper analyzes the transfer characteristics of CMOS transistors, by combining parallel currents of CMOS transistors in various W/L and negative bias voltages to realize the tunable analog predistortion function. The circuit is fabricated by a standard 0.18txm CMOS technology. The core circuit current consumption is only 15mA and the entire driver circuit works in a band-pass from 1 - 2.2GHz. Experimental results of two-tone tests have shown that with an analog predistortoer the IIP3 of the laser driver circuit has an improvement of 4.91 dB. 展开更多
关键词 radio-over-fiber (RoF) nonlinear analog predistorter parallel combination MOS transistor
下载PDF
Sensorless Predictive Algorithm for Permanent Magnet Brushless DC Drives
4
作者 Gianluca Brando Andrea Del Pizzo +2 位作者 Gianluca Gatto Ignazio Marongiu Alessandro Serpi 《Journal of Energy and Power Engineering》 2012年第7期1088-1096,共9页
A high resolution speed and position identification algorithm, suitable for brushless DC drives, is presented in this paper. In particular, the algorithm is proposed for BLDC (brushless DC) machines that are charact... A high resolution speed and position identification algorithm, suitable for brushless DC drives, is presented in this paper. In particular, the algorithm is proposed for BLDC (brushless DC) machines that are characterized by an un-ideal trapezoidal emfs shape. The algorithm, which is developed basing upon the MRAS technique (model reference adaptive system) and the Popov's hyperstability criterion, guarantees the convergence of the estimated rotor speed and position signals to their corresponding actual values. The identification procedure can be performed starting from the knowledge of low resolution rotor position signals, phase currents and the BLDC emfs shape. The identification algorithm is properly tested on a BLDC drive controlled by a predictive algorithm, by performing a simulation study in the Matlab-Simulink environment. The corresponding results have highlighted the effectiveness of the proposed sensorless predictive control system, at both low and high speed operation. 展开更多
关键词 Permanent magnet machines parameters estimation model reference adaptive control predictive control.
下载PDF
Analysis of Electrical and Non-electrical Causes of Variable Frequency Drive Failures
5
作者 Osama A. Al-Naseem Mohamed A. EI-Sayed 《Journal of Energy and Power Engineering》 2014年第4期693-701,共9页
VFDs (variable frequency drives) are an integral part of many industrial plants and stations. Reliable operation and maintenance of these drives is vital to ensure sustained plant operation and availability. Underst... VFDs (variable frequency drives) are an integral part of many industrial plants and stations. Reliable operation and maintenance of these drives is vital to ensure sustained plant operation and availability. Understanding of the principles of operation of VFD systems as well as knowledge about their required operating environment is necessary for all operating personnel. Many times the operating personnel do not get involved with different technical issues until a complete failure has occurred. Hence, the awareness of the most dominant failure causes has a significant impact on assisting operators to avoid catastrophic failures and tremendous economic losses due to VFD shutdown. Proper plant design, accurate monitoring and data logging, following manufacturer preventive maintenance schedule, and choosing qualified team of operators can be the key to an efficient operation and a long lifetime for any VFD system. In this paper, we have analyzed the electrical and non-electrical causes of VFD failures based on a case study of a typical medium voltage VFD pumping station. Finally, recommendations are given from field analysis and observations. 展开更多
关键词 VFDs (variable speed drives) ASD (adjustable speed drive) electrical fault causes non-electrical fault causes SCADA twelve-pulse power electric inverter rectifier flashover inverter short-circuit.
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部