The dynamic reactive power compensation equipment in Jiuquan Wind Power Base of above 10 GW consists of three different types of compensation devices, including: static var generator (SVG), thyristor controlled com...The dynamic reactive power compensation equipment in Jiuquan Wind Power Base of above 10 GW consists of three different types of compensation devices, including: static var generator (SVG), thyristor controlled compensator (TGR) and magnetically controlled reactor (MGR). The lack of experimental verification of performance is not conducive to voltage/var management or full utilization of device capaci- ties. In order to solve the above problems, the compensation device performance test was performed. The test items and procedures were selected based on related national standards with the consideration for different grid structures and wind farm operation modes. The testing contents included dynamic regulating range, active power loss, dynamic response time, and harmonic voltage level. Three types of compensation devices installed in different wind farms, namely SVG, TCR and MCR, were chosen and tested. The performances were compared and analyzed according to the field test results.展开更多
With the increasing development of wind power,the scale of wind farms and unit capacity of wind turbines are getting larger and larger,and the impact of wind integration on power systems cannot be ignored.However,in m...With the increasing development of wind power,the scale of wind farms and unit capacity of wind turbines are getting larger and larger,and the impact of wind integration on power systems cannot be ignored.However,in most cases,the areas with a plenty of wind resources do not have strong grid structures.Furthermore,the characteristics of wind power dictate that wind turbines need to absorb reactive power during operation.Because of the strong correlation between voltage stability and systems' reactive power,the impacts of wind integration on voltage stability has become an important issue.Based on the power system simulation software DIgSILENT and combined analysis of actual practice,this paper investigates the impacts of two types of wind farms on voltage stability:namely a type of wind farms which are constituted by constant speed wind turbines based on common induction generators(IG) and another type of wind farms which are constituted by VSCF wind turbines based on doubly-fed induction generators(DFIG).Through investigation the critical fault clearing time is presented for different outputs of wind farms.Moreover,the impacts of static var compensator(SVC) and static synchronous compensator(STATCOM) on transient voltage stability in IG-based wind farms are studied to improve the security and stability of the Jiangsu power grid after the integration of large scale wind power.展开更多
In response to acute predation threats, prey may sacrifice foraging opportunities in favour of increased predator avoidance. Under conditions of high or frequent predation risk, such tradeoffs may lead to reduced fitn...In response to acute predation threats, prey may sacrifice foraging opportunities in favour of increased predator avoidance. Under conditions of high or frequent predation risk, such tradeoffs may lead to reduced fitness. Here, we test the pre diction that prey reduce the costs associated with lost opportunities following acute predation threats by exhibiting shortterm compensatory foraging responses. Under seminatural conditions, we exposed female guppies Poecilia reticulate from high and low predation risk sites to one of three levels of acute predation threat (high, intermediate or low concentrations of conspecific alarm cues). Our results confirm previous reports, demonstrating that guppies from a high predation site were consistently 'bolder' (shorter escape latencies) and exhibited graded threatsensitive responses to different simulated threat levels while those from the low predation site were 'shyer' and exhibited nongraded responses. Most importantly, we found that when guppies from low predation sites resumed foraging, they did so at rates significantly lower than baseline rates. However, guppies from high preda tion sites resumed foraging either at rates equal to baseline (in response to low or intemaediate risk stimuli) or significantly in creased relative to baseline rates (in response to high risk stimuli). Together, these results highlight a complex compensatory be havioral mechanism that may allow prey to reduce the longterm costs associated with predator avoidance [Current Zoology 60 (3): 323-332, 2014 ].展开更多
文摘The dynamic reactive power compensation equipment in Jiuquan Wind Power Base of above 10 GW consists of three different types of compensation devices, including: static var generator (SVG), thyristor controlled compensator (TGR) and magnetically controlled reactor (MGR). The lack of experimental verification of performance is not conducive to voltage/var management or full utilization of device capaci- ties. In order to solve the above problems, the compensation device performance test was performed. The test items and procedures were selected based on related national standards with the consideration for different grid structures and wind farm operation modes. The testing contents included dynamic regulating range, active power loss, dynamic response time, and harmonic voltage level. Three types of compensation devices installed in different wind farms, namely SVG, TCR and MCR, were chosen and tested. The performances were compared and analyzed according to the field test results.
文摘With the increasing development of wind power,the scale of wind farms and unit capacity of wind turbines are getting larger and larger,and the impact of wind integration on power systems cannot be ignored.However,in most cases,the areas with a plenty of wind resources do not have strong grid structures.Furthermore,the characteristics of wind power dictate that wind turbines need to absorb reactive power during operation.Because of the strong correlation between voltage stability and systems' reactive power,the impacts of wind integration on voltage stability has become an important issue.Based on the power system simulation software DIgSILENT and combined analysis of actual practice,this paper investigates the impacts of two types of wind farms on voltage stability:namely a type of wind farms which are constituted by constant speed wind turbines based on common induction generators(IG) and another type of wind farms which are constituted by VSCF wind turbines based on doubly-fed induction generators(DFIG).Through investigation the critical fault clearing time is presented for different outputs of wind farms.Moreover,the impacts of static var compensator(SVC) and static synchronous compensator(STATCOM) on transient voltage stability in IG-based wind farms are studied to improve the security and stability of the Jiangsu power grid after the integration of large scale wind power.
文摘In response to acute predation threats, prey may sacrifice foraging opportunities in favour of increased predator avoidance. Under conditions of high or frequent predation risk, such tradeoffs may lead to reduced fitness. Here, we test the pre diction that prey reduce the costs associated with lost opportunities following acute predation threats by exhibiting shortterm compensatory foraging responses. Under seminatural conditions, we exposed female guppies Poecilia reticulate from high and low predation risk sites to one of three levels of acute predation threat (high, intermediate or low concentrations of conspecific alarm cues). Our results confirm previous reports, demonstrating that guppies from a high predation site were consistently 'bolder' (shorter escape latencies) and exhibited graded threatsensitive responses to different simulated threat levels while those from the low predation site were 'shyer' and exhibited nongraded responses. Most importantly, we found that when guppies from low predation sites resumed foraging, they did so at rates significantly lower than baseline rates. However, guppies from high preda tion sites resumed foraging either at rates equal to baseline (in response to low or intemaediate risk stimuli) or significantly in creased relative to baseline rates (in response to high risk stimuli). Together, these results highlight a complex compensatory be havioral mechanism that may allow prey to reduce the longterm costs associated with predator avoidance [Current Zoology 60 (3): 323-332, 2014 ].