This study presents the first demonstration project in China for treatment of coal-bed methane(CBM) co-produced water and recycling.The work aims to provide a research and innovation base for solving the pollution pro...This study presents the first demonstration project in China for treatment of coal-bed methane(CBM) co-produced water and recycling.The work aims to provide a research and innovation base for solving the pollution problem of CBM extraction water.The reverse osmosis(RO) unit is applied to the treatment of CBM co-produced water.The results indicate that system operation is stable,the removal efficiency of the total dissolved solids(TDS) is as high as 97.98%,and Fe,Mn,and F-are almost completely removed.There is no suspended solids(SS) detected in the treated water.Furthermore,a model for the RO membrane separation process is developed to describe the quantitative relationship between key physical quantities-membrane length,flow velocity,salt concentration,driving pressure and water recovery rate,and the water recovery restriction equation based on mass balance is developed.This model provides a theoretical support for the RO system design and optimization.The TDS in the CBM co-produced water are removed to meet the "drinking water standards" and "groundwater quality standards" of China and can be used as drinking water,irrigation water,and livestock watering.In addition,the cost for treatment of CBM co-produced water is assessed,and the RO technology is an efficient and cost-effective treatment method to remove pollutants.展开更多
The pilot performance of the combined GAC-MF membrane process for drinking water advanced treatment was described. In the process of GAC adsorption, under the conditions of 20 min HRT and 6 m/h filtration rate, the re...The pilot performance of the combined GAC-MF membrane process for drinking water advanced treatment was described. In the process of GAC adsorption, under the conditions of 20 min HRT and 6 m/h filtration rate, the removal efficiencies of UV_(254) and trichloromethane could reach 40% and 50% respectively and the UV_(254) and trichloromethane in system effluent was less than 0.015 cm^(-1) and 5μg/L respectively. In the post MF membrane process, MF membrane effectively retained the particles and bacteria in raw water. The effluent turbidity was less than 0.2 NTU and no bacteria were detected at all in permeate. A computer-controlled system was employed to control this system. The membrane operating parameters of backwash interval, duration and flux were studied. The backwash interval of 10-min, 20-min and 60-min was researched respectively, and the variation of trans-membrane pressure was also analyzed. Consequently short backwash interval was recommended under the same water consume.展开更多
基金Supported by the National Basic Research Program of China(2011ZX05060-0052009ZX05039-003)+2 种基金the National Natural Science Foundation of China(21106176)the President Fund of GUCAS(Y15101JY00)the National Science Foundation for Post-doctoral Scientists of China(20110490627)
文摘This study presents the first demonstration project in China for treatment of coal-bed methane(CBM) co-produced water and recycling.The work aims to provide a research and innovation base for solving the pollution problem of CBM extraction water.The reverse osmosis(RO) unit is applied to the treatment of CBM co-produced water.The results indicate that system operation is stable,the removal efficiency of the total dissolved solids(TDS) is as high as 97.98%,and Fe,Mn,and F-are almost completely removed.There is no suspended solids(SS) detected in the treated water.Furthermore,a model for the RO membrane separation process is developed to describe the quantitative relationship between key physical quantities-membrane length,flow velocity,salt concentration,driving pressure and water recovery rate,and the water recovery restriction equation based on mass balance is developed.This model provides a theoretical support for the RO system design and optimization.The TDS in the CBM co-produced water are removed to meet the "drinking water standards" and "groundwater quality standards" of China and can be used as drinking water,irrigation water,and livestock watering.In addition,the cost for treatment of CBM co-produced water is assessed,and the RO technology is an efficient and cost-effective treatment method to remove pollutants.
基金Sponsored by Fok Ying Tung Education Foundation (No. 94004)
文摘The pilot performance of the combined GAC-MF membrane process for drinking water advanced treatment was described. In the process of GAC adsorption, under the conditions of 20 min HRT and 6 m/h filtration rate, the removal efficiencies of UV_(254) and trichloromethane could reach 40% and 50% respectively and the UV_(254) and trichloromethane in system effluent was less than 0.015 cm^(-1) and 5μg/L respectively. In the post MF membrane process, MF membrane effectively retained the particles and bacteria in raw water. The effluent turbidity was less than 0.2 NTU and no bacteria were detected at all in permeate. A computer-controlled system was employed to control this system. The membrane operating parameters of backwash interval, duration and flux were studied. The backwash interval of 10-min, 20-min and 60-min was researched respectively, and the variation of trans-membrane pressure was also analyzed. Consequently short backwash interval was recommended under the same water consume.