期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
住宅工程验房机制与验房制度研究
1
作者 董群忠 《建筑经济》 北大核心 2022年第6期16-21,共6页
住宅工程“验房”关系群众利益,是重要的民生问题,通过对自助验房、第三方验房师验房、住户见证验收三种主要的验房方式的利弊分析,提出了建立科学规范的验房机制与验房制度的意见和建议,建立多元化验房机制,多渠道满足住房消费者验房... 住宅工程“验房”关系群众利益,是重要的民生问题,通过对自助验房、第三方验房师验房、住户见证验收三种主要的验房方式的利弊分析,提出了建立科学规范的验房机制与验房制度的意见和建议,建立多元化验房机制,多渠道满足住房消费者验房的需求,促进验房工作健康发展。 展开更多
关键词 机制 验房制度 自助 住户见证
下载PDF
An experimental investigation on decoupling performance for a lateral axis micromachined gyroscope with varying environmental parameters 被引量:1
2
作者 CUI Jian LIU XueSong +5 位作者 GUO ZhongYang ZHAO QianCheng LIN LongTao YANG ZhenChuan HAO YiLong YAN GuiZhen 《Science China(Technological Sciences)》 SCIE EI CAS 2011年第12期3415-3423,共9页
This paper carries out an experiment study of decoupling performance for a novel lateral axis micromachined gyroscope with varying environmental parameters. The non-ideal mathematical model for the coupling mechanism ... This paper carries out an experiment study of decoupling performance for a novel lateral axis micromachined gyroscope with varying environmental parameters. The non-ideal mathematical model for the coupling mechanism of the gyroscope is estab-lished through the gyro dynamic response matrix. The coupling components varying with ambient pressure and temperature induced by stiffness coupling, damping coupling and electrostatic force coupling are semi-analytically discussed. The overall coupling ratio is evaluated via experiments in the custom-built installation. The testing results show that the decoupling per-formance of the gyroscope is sensitive to the environmental parameters and all the non-ideal errors are determined as a function of ambient pressure and temperature. The coupling error varies from 0.05% to 0.25% within the pressure range of 100 Pa-100 kPa. The characteristics of coupling with temperature are measured from 20℃ to 100℃ with a variation from 0.35% to 0.41%. The results also indicate that within the range of measured ambient pressure and temperature, the minimum coupling ratio occurs at 100 Pa and room temperature. The overall performance of the gyroscope is tested under the pressure of about 2000 Pa and room temperature to achieve a relatively low coupling ratio. The scale factor is measured to be 7.8 mV (°)-1 s-1 with nonlinearity about 0.45% in the full-scale range of 600 (°) s-1. The short-term bias stability is approximately 0.06 (°)s-1 (1σ) for 20 min with noise equivalent angular rate evaluated to be 0.077 (°) s-1 Hz-1/2. 展开更多
关键词 DECOUPLING lateral axis gyroscope pressure temperature quadrature error
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部